Technical Details

Frequency: 

868.3 MHz

Modulation:  

FSK

Coding:  

Easywave A/B/C/D

Power supply: 

230 V AC

Power consumption:  max. 0.7 W
Range: 

up to 75 m under  

 

open field conditions

Degree of protection:   IP20
Operating temperature: -20 °C to +60 °C
Dimensions:  

48/48/25 mm

Weight: 

32.0 g

Scope of Delivery

Juncttion box transmitter, operating instructions

Intended Use

The Junction Box Transmitter may only be used 

to operate Easywave radio receivers in undim-

med load circuits.
The manufacturer shall not be liable for any da-

mage caused by improper or non-intended use.

Safety Advice

 Before using the device, carefully read 

through the operating instructions

Caution! Electrical installation may only be 

carried out by a qualified electrician!

Control unobserved never moving equipment or 

electric heaters. 
Note also the operating instructions of the radio 

receiver.
Have faulty radio controls checked by the 

manufacturer!
Do not make any unauthorized alterations or 

modifications to the transmitter!

Function

With  the  flush-mounted  transmitter  RTS39,  the 

functionality of existing switches or buttons can 

be extended by a radio interface.
If a voltage is present at a switch or button, the 

transmitter transmits the corresponding Easy-

wave code (A/B/C/D) to an Easywave receiver, 

which then switches another device.

Disposal

Waste electrical products and batteries not 

be disposed of with household waste!

Dispose of the waste product via a col-

lection point for electronic scrap or via 

your specialist dealer.
Put the packaging material into the 

recycling bins for cardboard, paper and 

plastics.

Warranty

Within the statutory warranty period we under-

take to rectify free of charge by repair or replace-

ment any product defects arising from material or 

production faults.

Any unauthorized tampering with, or modifica

-

tions to, the product shall render this warranty 

null and void.

Conformity

This product conforms to the basic   

requirements of the R&TTE Directive  

1999/5/EC.
For use in: EU/CH/FL/IS/N
The Declaration of Conformity can be found on 

the Internet at: www.eldat.de.

Service

If, despite correct handling, faults or malfunctions 

occur or if the product was damaged, please 

contact your retailer or the manufacturer.

ELDAT GmbH

Im Gewerbepark 14

15711 Königs Wusterhausen

Germany

Phone: + 49 (0) 33 75 / 90 37-310

Telefax: + 49 (0) 33 75 / 90 37-90

Internet: www.eldat.de

E-mail: [email protected]

UM100372D  0914  D/GB

General Information

1.  Mount the transmitter into a standard junction 

box.

Attention! 

Make sure there is no inter-fe-

rence with the wireless connection. Do not 

mount the device in a distribution box, in  me-

tal casings, in direct proximity to large metal 

objects, on the floor or close to it.

2.  Use with the jumper J the desired mode. Fac-

tory, the transmitter is supplied to the switch 

operation (jumper J plugged). 

3.  Connect the power supply wires and switches 

or buttons in a voltage-free state as shown in 

Start-Up

the connection diagram.

 

Attention!

 Check with local electrical regula-

tions! 

4.  Put the lid on the junction box. Then turn off 

the power supply again. Memorize the trans-

mission code in the receivers. Please read 

the operating instructions supplied with the 

receivers.

If the switch / button now pressed, the transmitter 

transmits the appropriate control command to the 

receiver. 

Connection Diagram

Connection to a switch

S2

S1

J

N

N

230 V 

L

L

S1 S2

L

Connection to a push-button

J

N L

T2 T3

T1

N

230 V 

L

L

T

Connection to a shutter-control

T2

T1

J

N L

T2 T3

T1

N

230 V 

L

ZU

AUF

L

Jumper J 

is 

plugged

The transmission starts on every change of state 

of the switch and lasts approx. 0,5 seconds.

switch 1: Input S1
transmission-code A: close switch

transmission-code B: open switch
switch 2: Input S2

transmission-code C: close switch

transmission-code D: open switch

Jumper J 

is

 not plugged

Transmission lasts as long as the button is 

pressed but max. 10 seconds.

push-button 1: Input T1  transmission-code A 
push-button 2: Input T2  transmission-code B
push-button 3: Input T3  transmission-code C
Several inputs can not be switched simultane-

ously.

Jumper J

 is 

not plugged

Transmission lasts as long as the button is 

pressed but max. 10 seconds. 

push-button 1: Input T1  transmission-code A 
push-button 2: Input T2  transmission-code B
Several inputs can not be switched simultane-

ously.

1

1 Jumper

All connecting lines (N, L, S1 and S2, T1 to T3) should be directly (<2 m) connected to the 

switch/push button which is upgraded.

Отзывы: