background image

L

N

230VAC

GND

RXD

TXD

ANT GND

ext.

RCD22E5001A01

RCD22E5001A01

Technical Data

Frequency: 

868.30 MHz

Modulation:  

FSK

Coding:  

Easywave

Output: 

RS232 interface

Power supply: 

230 V AC 50 Hz

Power consumption: 

1.5 W standby

Degree of Protection: 

IP66 (in delivery state) 

Operating temperature:  -20 °C to +60 °C

Dimensions (w/l/h):  

34.5/89.6/62.8 mm

Weight: 

260 g

Scope of Delivery  

Radio control RCD22, mounting accessories, 

operating instructions

Intended Use

The device is only intended as a radio receiver for 

receiving Easywave radio telegrams and output-

ting hexadecimal values.
The manufacturer shall not be liable for any da-

mage caused by improper or non-intended use.

Safety Advice

 Carefully read through these instruc-

tions before connecting and operating 

the unit! 

Caution!

 

Electrical installation 

may only be carried out by a 

qualified  electrician;  other

-

wise there is a risk of electric 

shock or fire

.

Observe the applicable laws, standards and re-

gulations as well as the manufacturer’s instruc-

tions for the devices to be operated!

The control unit may not be operated by children 

or unauthorised persons!
Have faulty units checked by the manufacturer!!

Do not make any modifications to the device!

Function

The RCD22 receives Easywave telegrams and 

forwards them as hexadecimal values via the 

RS232 interface to a receiving device (PC).
Where environmental conditions are unfavorable, 

the external antenna ACC-ANT50-03-21P can be 

connected to improve wireless reception. This is 

not included with the product, but can be ordered 

separately.

RCD22   Radio control with serial interface

EN

Model

Mounting

Do not install the control near the floor or in ni

-

ches, as there may be a radio shadow here. 

When mounting on metal surfaces, a minimum 

distance of 10 cm should be maintained. 

The receiver must be installed by a qualified elec

-

trician, connected according to the connection 

diagram and put into operation. 

1.  Switch off the power supply.

2.   Unscrew the housing cover.
3.  Attach the controller to the installation site. 

Use the screw gears of the cover screws.

Wire cross-sections

rigid wires:
0.5 – 2.5 mm² 
Flexible wires with 

ferrule:  

0.5 – 1.5 mm²

Attention: 

Mount the 

antenna outside of  

metal housings.

Connection terminal

Power supply

230V AC 50Hz

Connection terminal

RS232 interface

Connection terminal

external antenna

ACC-ANT50-03-21P

230 V AC 

50 Hz

optional

white  GND

red  GND

black  ANT

black  TXD

Terminal assignment RCD22

Connection 

cable

RCD22

Pin

PC

black

TXD 

2

 

RXD

red

GND

5

GND

2

5

INSTALLING THE RECEIVER 

4.  Push the connection cable through the doub-

le-membrane seals. Pull the cable back brief-

ly to form the seal.

5.  Connect the connecting cables for the RS232 

interface to GND and TXD according to the 

„Terminal assignment RCD22“. 

6.  Connect the connecting cables for the power 

supply according to the terminal assignment.

7.  Screw the housing cover back.
8.  Switch on the power supply. 

TXD

GND

Terminal assignment

 9-pin Sub-D socket

Отзывы: