27
M
EASURING
SIZE
OF
REINFORCEMENT
BARS
(
ORTHOGONAL
R
9 MEASURING SIZE OF REINFORCEMENT BARS (ORTHOGONAL)
Although the Covermeter includes the AutoSize feature (see page 26), a separate ‘orthogonal’ SIZE
function is included for accurate measurement of bar size.
The orthogonal SIZE function is intended to be used to determine the diameter of a (single)
reinforcement bar. Although the associated cover will also be displayed, this function is not intended
to be used for scanning areas.
Orthogonal sizing can be performed at greater depths than the AutoSize function.
The following sections describe how to use the SIZE function.
9.1 Before you start
•
Are you using the correct search head?
See “Search heads” on page 55.
•
What units of measurement do you want to use?
See “SETUP” on page 15.
9.2 Procedure
1. Connect the search head to the Covermeter.
2. Switch on the Covermeter.
3. Ensure the instrument is set to Cover mode.
MENU / INSTRUMENT MODE / COVER
4. Zero the Covermeter.
5. Set sound mode to ‘locate’ -
MENU / SETUP / SOUND MODE / LOCATE.
6. Press the SIZE softkey. The display will show:
7. Adjust sensitivity - see “Adjusting sensitivity” on page 34.
8. Locate the exact position and orientation of the reinforcement bar using the sound, the LED
and the display as indicators - see “Locating reinforcement bars” on page 18.
331.book Page 27 Thursday, March 12, 2009 9:46 PM