![Elcometer 331 B Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/elcometer/331-b/331-b_operating-instructions-manual_2377331017.webp)
13
T
HE
MENUS
R
4.2 INSTRUMENT MODE
j
COVER . . . . . . . . . . . . . . . . . Sets the instrument to measure depth of cover
HALFCELL . . . . . . . . . . . . . . Sets the instrument to measure half-cell potential
4.3 SETUP
UNITS . . . . . . . . . . . . . . . . . . Opens Units menu . . . . . . . . . . . . . See 4.6 UNITS
BEEP VOLUME. . . . . . . . . . . Use Scroll keys to select beep volume 0 (off) to 5 (maximum)
and then press Enter
LANGUAGE. . . . . . . . . . . . . . Use Scroll keys to select menu language and then press enter
AUTO SWITCH OFF . . . . . . . Use Scroll keys to select auto switch off time, 5 to 10 minutes
or off and then press Enter
OPENING SCREEN . . . . . . . Press Enter to toggle the opening screen on or off
LCD CONTRAST. . . . . . . . . . Use Scroll keys to select LCD contrast, 0 to 8 and then press Enter
4.4 ABOUT
GAUGE INFORMATION . . . . Press Enter to display technical information about the
Covermeter
PROBE INFORMATION . . . . Press Enter to display technical information about the search
head
CONTACT . . . . . . . . . . . . . . . Press Enter to display Elcometer offices worldwide and
(if programmed) Supplier contact details
HELP . . . . . . . . . . . . . . . . . . . Press Enter to display an explanation of all the symbols
used on the display
4.5 RESET
INTL GAUGE. . . . . . . . . . . . . Press Enter to Reset Covermeter to International settings
k
(DD/MM/YYYY date format, metric units, etc.)
USA GAUGE . . . . . . . . . . . . . Press Enter to Reset Covermeter to USA settings
l
(MM/DD/YYYY date format, imperial units, etc.)
Note:
The Covermeter will display a Yes/No confirmation screen before reset is activated.
4.6 UNITS
MM. . . . . . . . . . . . . . . . . . . . . (Millimetres) Use Scroll keys to select units, then press Enter
INCH . . . . . . . . . . . . . . . . . . . (Inches) Use Scroll keys to select units, then press Enter
j.
‘Instrument mode’ is not included on Elcometer Model B.
k.
International settings can also be activated at switch on:
Press and hold third softkey
and switch on gauge.
l.
USA settings can also be activated at switch on:
Press and hold fourth softkey
and switch on gauge.
331.book Page 13 Thursday, March 12, 2009 9:51 PM