1.2 WHAT THE BOX CONTAINS

Elcometer 213/2 Digital Thermometer with battery fitted

Operating instructions

Note:  A probe is not supplied with the thermometer. Probes must be
ordered separately - see “Spare parts and accessories” on page 8.

The Elcometer 213/2 Digital Thermometer is packed in a cardboard and
foam package. Please ensure that this packaging is disposed of in an
environmentally sensitive manner. Please consult your local
Environmental Authority for further guidance.

To maximise the benefits of your new Elcometer 213/2 Digital
Thermometer please take some time to read these Operating
Instructions. Do not hesitate to contact Elcometer or your Elcometer
supplier if you have any questions.

2 FITTING A BATTERY

When the battery voltage becomes low, ‘LO BAT’ is shown on the display.
The instrument will continue to measure accurately while ‘LO BAT’ is
shown, but changing the battery at the earliest convenience is
recommended.

When the battery voltage becomes too low for the gauge to measure accurately, 'Flat' and then 'Bat' is
shown on the display and the gauge will then switch off. The battery must be replaced at this time to
continue using the gauge.

Содержание 213/2

Страница 1: ...en Elcometer 213 2...

Страница 2: ...R en ThThis product meets the Electromagnetic Compatibility Directive The product is Class B Group 1 ISM equipment according to CISPR 11...

Страница 3: ...R en CONTENTS Section Page 1 About your gauge 2 2 Fitting a battery 3 3 Fitting a probe 4 4 Taking a reading 5 5 Changing measurement units 6...

Страница 4: ...ngs and concrete Our products cover all aspects of coating inspection from development through application to post application inspection Your Elcometer 213 2 Digital Thermometer is a world beating pr...

Страница 5: ...probe is not supplied with the thermometer Probes must be ordered separately see Spare parts and accessories on page 8 The Elcometer 213 2 Digital Thermometer is packed in a cardboard and foam packag...

Страница 6: ...way the cover 2 Remove the battery by pushing it to one side 3 Fit the new battery into the battery clips taking care to observe the correct polarity 4 Replace the battery compartment cover ensuring t...

Страница 7: ...e to the substance medium or surface to be measured The reading on the display may take a number of seconds to stabilise depending on the nature of the measurement and the sensitivity of the probe 3 I...

Страница 8: ...5 CHANGING MEASUREMENT UNITS To change the instrument units from C to F or vice versa 1 Switch off the gauge 2 Press but do not release the button 3 While continuing to press press to switch on the g...

Страница 9: ...he gauge to a strong impact Clean the gauge with a soft dry cloth such as those made to clean eyeglasses Do not use solvents This gauge incorporates a Liquid Crystal Display If the display is heated a...

Страница 10: ...CCESSORIES The following spare parts and accessories are available direct from Elcometer or your local supplier Beschrijving Reeks Artikelnummer Magnetic Surface Probe 13mm 0 51 Diameter 50 C to 150 C...

Страница 11: ...S Measurement Range 49 C to 1372 C 56 F to 2500 F Resolution 0 1 C 0 1 F up to 299 9 C 599 9 F 1 C 1 F above 299 9 C 599 9 F Accuracy 1 of the reading 1 digit Probe K type Thermocouple Ambient Tempera...