2 GETTING STARTED

2.1 FITTING BATTERIES
The Elcometer 121/2 Universal P.I.G. uses dry cell batteries only.
To fit or replace the battery: Use a coin to loosen and open the slotted screw beside the eye-piece. Remove
battery and replace with new battery 1.5 V (leakproof), positive end first. Reclose in reverse order.

Note: 

Remove the batteries from the instrument if it is to remain unused for a long period of time. This will

prevent damage to the instrument in the event of malfunction of the batteries. 
Batteries must be disposed of carefully to avoid environmental contamination. Please consult your local
Environmental Authority for information on disposal in your region.

Do not dispose of any batteries in fire.

2.2 REPLACING THE BULB
Screw objective lens into the instrument until the bulb is easily accessible. Loosen bulb holder slightly with
small hexagonal wrench and screw out the bulb. Screw in the spare bulb (1.2 V, 0.22 A) and re-secure the
bulb holder.
Check Light Spot: To do this, place the PIG in measuring position over a textured object (for example, a
newspaper) and switch the light on. The light spot, with its maximum brightness, must lie below the centre
of the objective lens. If not, loosen the bulb holder with the hexagonal wrench and move it until the light spot
is correctly placed. Then secure the holder.

Содержание 121/2

Страница 1: ...English Elcometer 121 2 Universal Paint Inspection Gauge Operating Instructions...

Страница 2: ...ansmitted transcribed stored in a retrieval system or otherwise or translated into any other language in any form or by means electronic mechanical magnetic optical manual or otherwise without the pri...

Страница 3: ...ting started 4 3 Mounting and changing tools 5 4 Measuring film thickness 7 5 Measuring cross cut adhesion 10 6 Measuring indentation hardness Buchholz 12 7 Spare parts and accessories 14 8 Fault chec...

Страница 4: ...rt network of Elcometer For more information visit our website at www elcometer com 1 ABOUT YOUR GAUGE The Elcometer 121 2 Universal P I G Paint Inspection Gauge offers a quick versatile method of coa...

Страница 5: ...nal wrench 1 5 mm Hexagonal wrench 2 5 mm Marker pen Spare bulb lens bulb 1 2 V 0 2 A Spare battery Mignon leak proof 1 5 V Carrying case Operating instructions The instrument is packed in a cardboard...

Страница 6: ...tal contamination Please consult your local Environmental Authority for information on disposal in your region Do not dispose of any batteries in fire 2 2 REPLACING THE BULB Screw objective lens into...

Страница 7: ...ad and re tighten screw CROSS CUT KNIVES Positions 4 and 5 These are located by means of two hexagonal screws each small hexagonal wrench M 1 5 laterally from the receptacle slots of the rotary head T...

Страница 8: ...one cutter to another first press the Stop knob against the casing Then turn the rotary head to the desired position and lock it by releasing the Stop knob Note Care must be taken that the Stop knob...

Страница 9: ...a little pressure Slight pressure is normally sufficient to penetrate through to the substrate Heavier pressure may be required for very thick coatings and very hard surfaces 3 Position the gauge so...

Страница 10: ...x 2 68 microns or 34 divisions x 0 08 2 7 mils 4 1 MEASURING MULTI LAYER COATINGS The thickness of individual layers can be calculated by measuring each layer 4 2 IRREGULARITIES Irregularities can occ...

Страница 11: ...x always measure distance A to obtain the thickness of the coating single layer of coating in this example NO SEPARATION When measuring the thickness of clear varnish on wood there may be no visible...

Страница 12: ...ING BLADES A range of cutting blades is available for different thicknesses and types of coating Mount the cutting blades in positions 4 and 5 5 2 ANALYSING THE RESULTS Assess the coating adhesion by...

Страница 13: ...greater than 5 but not significantly greater than 15 is affected 2 3B The coating has flaked along the edges of the cuts partly or wholly in large ribbons and or it has flaked partly or wholly on dif...

Страница 14: ...tool in contact with the test area 4 Leave the PIG for 30 seconds timed using a stopwatch and then lift the PIG carefully away from the surface 5 Remove the weight 6 Position the PIG so that the micr...

Страница 15: ...h a measurement is valid mm m mils m mils 0 8 125 5 0 2 15 0 59 0 85 118 6 0 24 20 0 79 0 9 111 7 0 28 20 0 79 0 95 105 7 0 28 20 0 79 1 0 100 8 0 31 20 0 79 1 05 95 9 0 35 20 0 79 1 1 91 10 0 39 20 0...

Страница 16: ...ls T12112191 Cutter No 2 10 m to 1000 m 0 4 mils to 40 mils T12112192 Cutter No 3 2 m to 200 m 0 08 mils to 8 mils T12112193 Cross hatch cutter 1 mm ISO DIN T12112185 Cross hatch cutter 2 mm ISO DIN T...

Страница 17: ...e gauge to your Elcometer supplier Battery cannot be removed Unsuitable non leakproof battery used Return the gauge to your Elcometer supplier All cuts are rough and ragged Point of cutter tool damage...

Страница 18: ...ons or on the Elcometer website www elcometer com 10 RELATED EQUIPMENT In addition to the Elcometer 121 2 Universal P I G Elcometer produces a wide range of other equipment for testing and measuring t...

Отзывы: