Installing the REMOCON NET B
Types of possible installations
en
WARNING!
Installation should be performed
by a qualified technician.
Before installing, disable the power
supply to the boiler. The BUS BSB
cable is polarised: to avoid problems
when the system is started up, observe
the polarities (CL+ with CL+ and CL-
with CL-) between all system
components.
The term “Remote Control” (RC) means
the service directed to end user, through
which they can use the smartphone App or
web portal to monitor and set their ELCO
product.
The following paragraph lists some of the main system arrangements which are
possible using REMOCON NET B and other accessories already found in the ELCO
product range, as well as the types of service that can be activated using these
configurations. For more information and details about the installation configurations
shown below, we would ask you to contact the representative for your area.
Type 1
TC activation in a basic heating system
with power supplied using a G+ cable:
Connect the REMOCON NET B
Gateway to the boiler using the BSB
communication BUS (CL + and CL-) and
the G+ power supply cable
Warning!
This type is only available if
no room thermostat
has be connected to the G+ power
supply cable
Fig. 1
Installing REMOCON NET B and activating
the REMOCON NET services is quick
and easy:
it takes just 3 steps!
INSTALLING THE
REMOCON NET B
ACCOUNT
REGISTRATION
CONNECTING
TO THE INTERNET
AND REGISTERING
THE PRODUCT
Type 2
TC activation in a basic heating system
with an external power supply:
Connect the REMOCON NET B
Gateway to the boiler using the BSB
communication BUS (CL + and CL-)
Connect the external transformer to the
REMOCON NET B Gateway, then
connect it to the electrical mains
Fig. 2
BUS
G+
BUS
12V
ROOM DEVICE
REMOCON NET B
REMOCON NET B