TEACH
DOWN
UP
Set response
speed
TEACH
SPEd
H.rSo
10ms
Std
5ms
FASt
1.5ms
UP
DOWN
TEACH
L-d
L-on
d-on
TEACH
SEnS
_|
 ̄
_N_.1
_N_.2
_N_.3
TEACH
P-n
nPn
PnP
NPN
PNP
TEACH
HySt
short press
UP/DOWN
,
step
0.1mm
;
long press
UP/DOWN above 3s
,
step
1mm
UP
DOWN
UP
DOWN
UP
DOWN
STEP
UP/DOWN
(TEACH)
UP/DOWN
(TEACH)
UP/DOWN
(TEACH)
UP/DOWN
(TEACH)
UP/DOWN
(TEACH)
UP/DOWN
(TEACH)
UP/DOWN
(TEACH)
Long press
TEACH
,
Enter the menu interface
TEACH
Eco
oFF
on
close
open
DOWN
UP/DOWN
(TEACH)
Erig
TEACH
InPt
L-oF
L-on
DOWN
UP/DOWN
(TEACH)
UP/DOWN
(TEACH)
external input
TEACH
rSEt
no
yES
DOWN
UP/DOWN
(TEACH)
1.Ranging diaplay
Measurement interface
:
Show actual measurement distance
,
resolution is 0.1mm
,
when the
distance is out of detected distance,it diaplays“----”
。
2.Menu and key operation
2.1 Enter the menu
:
Long pressTEACH above 3s when it is in the measurement interface
,
enter the menu interface
;
Exit menu
:
Long pressTEACH above 3s when it is in the menu interface
,
or no key operation for 20s
,
return to measurement interface
。
2.2 Menu operation
Enter the menu interface,diaplay the main menu,switch the menu options by pressing the up/down key.
On the main menu interface,enter the submenu options by short pressing TEACH key.Unter the submenu,
short press up/down to select the parameter.Short press the TEACH key to confirm and return to the
previous main menu.
1)Set detection output
The main menu shows
“
SEnS
”,
press TEACH to enter the submenu;
Submenu items
:“__| ̄”
usually detected mode
(
default
);“_
N
_.
1
”
1-point teaching window comparison mode
;
“_
N_.2
”
2-point teaching window comparison mode
;“_
N_.3
”
3-point teaching window comparison mode
。
When
teaching window comparison mode at 1-point ,short press the TEACH key to enter the window size setting
interface
;
the
nitial value is 0.5mm,press up/down to adjust the window size parameter,step 0.5mm,long press up/down
for more than 3s,step 5mm.
After selecting the teaching mode,you can teach on the measurement interface.If the teaching succeeds,“good” will be
displayed,if the teaching fails,“FAil” will be displayed.
Please refer to the specific mode description for the above 3 teaching modes.
2)Set response speed:
The main menu shows“SPEd”
,
press TEACH to enter the submenu;
Submenu items
:“
H.rSo
”
high precision
10ms
;“
Std
”
standard
5ms
;
“
FASt
”
high speed
1.5ms
(
default
);
3)Set diaplay mode
The main menu shows
“
diSP
”,
press TEACH to enter the submenu;
Submenu items
:
“norN”normal displacement mode
(
default
);
“rEv”reverse displacement mode
;
“dist”distance mode
.
4)Set analog output ditection
The main menu shows
“
Ao.d
”,
press TEACH to enter the submenu;
Submenu items
:“
Ao-F
”
forward
(
default
);“
Ao-r
”
reverse
。
5)Set output action
The main menu shows
“
L-d
”,
press TEACH to enter the submenu;
Submenu items
:“
L-on
”
luminous
(
default
);“
d-on
”
dark pass
;
6)Set switch output
The main menu shows
“
P-n
”,
press TEACH to enter the submenu;
Submenu items
:“
nPn
”
NPN
output mode
(
default
);“
PnP
”
PNP
output mode
.
7)Anti-shake settings
The main menu shows
“
HySt
”,
press TEACH to enter the submenu;
Submenu initial diaplay
“
0.1
”,
0.1mm is hysteresis distance
,
short press
UP/DOWN
,
step
0.1mm
;
long press
UP/DOWN above 3s
,
step
1mm
。
Setting range is 0~5mm
,
initial value is 3mm
。
8)Environmental protection settings
The main menu shows
“
Eco
”,
press TEACH to enter the submenu;
Environmental protection function note
:
After the function is turned on,the LED will automatically turn off the display in
30s without any button.
9)External output settings
The main menu shows
“
InPt
”,
press TEACH to enter the submenu;
Submenu items
:“
L-oF
”
stop cast light
;“
L-on
”
turn on cast light
;“
Erig
”
external input
(
default
);
External input
note
:
When the external input is low,stop cast light
,
no external input,default turn on cast light
。
10)Reset settings
The main menu shows
“
rSEt
”,
press TEACH to enter the submenu;
Submenu items
:“
no
”
do not perform reset
;“
yES
”
perform reset
,
restore default settings.
2.3 Key lock function
On the measurement interface
,
both press TEACH and DOWN key for above 3s
,
interface display“Lc.on”
,
the key lock
,
menu function failure
,
automatic return to the measurement interface after a delay of 3s.both press TEACH and DOWN
key for above 3s again
,
interface display“Lc.oF”
,
key function recovery
,
automatic return to the measurement interface
after a delay of 3s.
UP/DOWN
TEACH
diSP
norN
rEv
UP
DOWN
UP/DOWN
(TEACH)
dist
UP/DOWN
(TEACH)
TEACH
Ao.d
Ao-F
Ao-r
Set analog
output ditection
UP/DOWN
(TEACH)
UP
DOWN
OPERATION GUIDE
OSM40 High Precision Laser
Distance Sensor
1-point
teaching
2-point
teaching
3-point
teaching
Set diaplay mode
normal
reverse
distance
reverse
forward
Set output action
dark pass
luminous
Set detection output
usually
detected
Set switch output
Anti-shake settings
Environmental
protection settings
External output settings
stop
cast light
turn on
cast light
Reset settings
perform reset
do not