1
Control board for rolling-shutters with limit-switches.
REV 0.A
FOLLOW THIS
INSTRUCTIONS
CAREFULLY !!
This manual
contains important instructions for
the installation and use of the
board mod. “VENUS2s”. Don’t install
before reading this manual, the
product’s security depends on a
correct installation. The installation
must be done by qualified
technicians. The board must have a
special box to protect from water
infiltration or damp. The board
mustn't be exposed to sources of
heat or electromagnetic fields.
Install the board in airy place and
far from inflammable material. The
producing company declines any
responsibility in case of a not
correct installation or improper
use
.
The product respects the European
norms: 2006/95/CE (CEE73/23,
CEE93/68),2004/108/CE (CEE89/336),
CEE89/106, CEE89/392,
FIG1
INPUTS
FUNCTION
TERMINALS’CONNECTIONS
START / STOP
Norm. open
Commands:
OPEN> STOP > CLOSE > STOP >….
During the pause time a command
excludes the automatic closing.
Terminals 7 [com] and 8 [SS]
STOP
Norm. close
Stops the rolling-shutter and
excludes the automatic closing.
Terminals 7 [com] and 9 [STOP]
If you don’t use it, short-circuit the terminals 7and 9
PHOTO-CELLS
Norm. close
During the closing time it inverts the
movement of rolling-shutter in
opening time.
Connect the photo-cells’ alimentation to 24Vac
output of board (1 couple max).
The NC contact of photo-cell (receiver) must be
connected to terminals 7 [com] and 10 [PHOT.]
If you don’t use it, short-circuit the terminals 7and 10
MOTOR AND ALIMENTATION’S CONNECTIONS
TERMINALS’CONNECTION
ATTENTION !
The installation
must have a switch with opening
contacts at least 3mm for the
omnipolar disconnection. The
change tension and the wiring connections
can be made after to have disconnected the
alimentation ! DISCONNECT THE GENERAL
SWITCH before every connections !
SINGLE-PHASE MOTOR 230Vac
500W MAX
Connect the motor to terminals:
1 (closing),
2 (opening),
3 (comune)
BOARD’S ALIMENTATION:
230Vac 50Hz
Connect the alimentation to
terminals:
4 (NEUTRO)
5 (PHASE)
SYMBOLS
IMPORTANT !! for
product’s use
INFORMATION for the
installation security
DANGER in presence
of high tension !
IMPORTANT !!!
All the wiring connections must be done after to
have disconnected the main alimentation !
DISCONNECT THE GENERAL SWITCH before every connection !!
2
BOARD PROGRAMMING
BASE PROGRAM
The board has a BASE program.
You can come back to the BASE
program, making the Reset
procedure.
MOTOR’S RUN: 30sec
AUTOMATIC CLOSING: Excluded
RADIO CODE
Standard transmitter
53200
Button 1
Dip code :
1,3,5,7,9 in ON position
2,4,6,8,10 in OFF position
RESET PROCEDURE
The reset procedure allows to
come back to the BASE program,
deleting all the programs
memorised.
With the reset
procedure you come
back to the BASE
code (standard
transmitter 53200, button n.1,
dip1,3,5,7,9 in OFF position and
dip2,4,6,8,10 in ON position)
PROCEDURE
PICTURES
1) Turn off the board and put a
little bridge on JA
2) ) Turn on the board
3) When the OK led starts to
flash , take off the little bridge
JA
4) When the OK led turns off,
the reset procedure is ended
RADIO COMMANDS
the board can be commanded by the transmitter. You can memorise n.
41 standard-codes or
n.15 rolling-codes
. The BASE code is (standard 53200, button n.1, dip 1,3,5,7,9 in ON position and dip 2,4,6,8,10 in OFF position),
it’s erased with the first code that you memorise.
ATTENTION!!: To use the transmitter, the board must have the radio receiver. (see fig.1 , pag.1)
ROLLING-CODES !.
If the first code memorised is a
Rolling-code, the board stops to receive the standard-codes 53200(
10dip). To receive the standard-codes 53200 you have to make the reset procedure (see pag.2).
TRANSMITTERS PROGRAMMINGI ! When you program the transmitters, you have to keep a distance at least 50cm between
the transmitter and the board..
PERSONAL CODE ! If you use the standard-codes (10-dip) you have to put a personal code, positioning the 10 dips on the
transmitter, before to memorise the board
.
After to have memorised the new code on board you can’t change the dip position on
the transmitter!
START/STOP CODES
PROGRAMMING (SS)
START/STOP function to command
the motor.
For this procedure you have to use
the little bridge JUMPER A:
PROCEDURE
PICTURES
1) Put the little bridge on JA.
The OK led turns on..
2) Send a radio code that you
want to memorise.
3) The OK led makes a fast flash if
the code has been memorised,
or it makes a slow flash if the
code is just in memory.
(If the OK led makes 3 flashes that
means the memory is full and you
can’t memorise other codes.)
1 fast flash:
1 slow flash:
code memorised
code is just in memory
4) If you want to memorise other
radio codes SS, you have to
repeat from point 2 or take off
the little bridge JA