background image

1

  

   

 

Control board for rolling-shutters with limit-switches. 

 

REV 0.A 

 

 

 

 FOLLOW THIS 
INSTRUCTIONS 
CAREFULLY !! 

 

This manual 

contains important instructions for 
the installation and use of the 
board mod. “VENUS2s”. Don’t install 
before reading this manual, the 
product’s security depends on a 
correct installation. The installation 
must be done by qualified 
technicians. The board must have a 
special box to protect from water 
infiltration or damp. The board 
mustn't be exposed to sources of 
heat or electromagnetic fields.

 

 

Install the board in airy place and 
far from inflammable material. The 
producing company declines any 
responsibility in case of a not 
correct installation or improper 
use

 

The product respects the European 
norms: 2006/95/CE (CEE73/23, 
CEE93/68),2004/108/CE (CEE89/336), 
CEE89/106, CEE89/392, 
 

 

     

FIG1 

 

 

 

INPUTS 

FUNCTION 

TERMINALS’CONNECTIONS 

START / STOP 
Norm. open 

Commands: 
 OPEN> STOP > CLOSE > STOP >…. 
During the pause time a command 
excludes the automatic closing. 

Terminals 7 [com] and 8 [SS]  

STOP  
Norm. close 
 

Stops the rolling-shutter and 
excludes the automatic closing. 

Terminals 7 [com] and 9 [STOP] 

 

If you don’t use it, short-circuit the terminals 7and 9 

PHOTO-CELLS 
Norm. close 

During the closing time it inverts the 
movement of rolling-shutter in 
opening time. 
 

Connect the photo-cells’ alimentation to 24Vac 
output of board (1 couple max)
The NC contact of photo-cell (receiver) must be 
connected to terminals 7 [com] and 10 [PHOT.] 

 

If you don’t use it, short-circuit the terminals 7and 10 

MOTOR AND ALIMENTATION’S CONNECTIONS 

TERMINALS’CONNECTION 

ATTENTION ! 

The installation 

must have a switch with opening 
contacts at least 3mm for the  
omnipolar disconnection. The 

change tension and the wiring connections 
can be made after to have disconnected the 
alimentation ! DISCONNECT THE GENERAL 
SWITCH
 before every connections !

 

 

SINGLE-PHASE MOTOR 230Vac 
500W MAX 

 

Connect the motor to terminals: 
1 (closing),  
2 (opening),  

3 (comune) 

BOARD’S ALIMENTATION: 

230Vac   50Hz  

Connect the alimentation to 
terminals: 
4 (NEUTRO)  
5 (PHASE) 

SYMBOLS 

 

IMPORTANT !! for 

product’s use 

 

INFORMATION for the 

installation security 

 

DANGER in presence 

of high tension !  

 

IMPORTANT !!! 

All the wiring connections must be done after to 

have disconnected the main alimentation !  
DISCONNECT THE GENERAL SWITCH before every connection !! 
 

 

2

BOARD PROGRAMMING 

BASE PROGRAM 

The board has a BASE program. 
You can come back to the BASE 
program, making the Reset 
procedure. 

MOTOR’S RUN: 30sec 

AUTOMATIC CLOSING: Excluded 

RADIO CODE 

Standard transmitter 

53200 
Button 1   
Dip code :  
1,3,5,7,9   in ON position  
2,4,6,8,10 in OFF position 

RESET PROCEDURE 

 

The reset procedure allows to 
come back to the BASE program, 
deleting all the programs 
memorised. 

 

With the reset 
procedure you come 
back to the BASE 
code (standard 

transmitter 53200, button n.1, 
dip1,3,5,7,9 in OFF position and 
dip2,4,6,8,10 in ON position)

 

PROCEDURE  

PICTURES 

1) Turn off the board and put a 
little bridge on JA 

         

 

2) ) Turn on the board 

 

3) When the OK led starts to 
flash , take off the little bridge 
JA 

                                                                                

 

   

4) When the OK led turns off, 
the reset procedure is ended 

       

 

RADIO COMMANDS 

the board can be commanded by the transmitter. You can memorise n. 

41 standard-codes or 

n.15 rolling-codes

. The BASE code is (standard 53200, button n.1, dip 1,3,5,7,9 in ON position and dip 2,4,6,8,10 in OFF position), 

it’s erased with the first code that you memorise. 
ATTENTION!!: To use the transmitter, the board must have the radio receiver.  (see fig.1 , pag.1) 

 

 

ROLLING-CODES !.

 If the first code memorised is a

 Rolling-code, the board stops to receive the  standard-codes 53200( 

10dip). To receive the standard-codes  53200 you have to make the reset procedure (see pag.2).

 

TRANSMITTERS PROGRAMMINGI ! When you program the transmitters, you have to keep a distance at least 50cm between 
the transmitter and the board..

 

PERSONAL CODE ! If you use the standard-codes (10-dip) you have to put a personal code, positioning the 10 dips on the 
transmitter, before to memorise the board

After to have memorised the new code on board you can’t change the dip position on 

the transmitter!

 

 

START/STOP CODES 
PROGRAMMING (SS) 

 

 

START/STOP function to command 
the motor. 
 
For this procedure you have to use 

the little bridge JUMPER A

 

 

PROCEDURE

  

                  PICTURES 

1) Put the little bridge on JA.  
The OK led turns on.. 

 

   

   

 

2) Send a radio code that you 
want to memorise.  

  

 

3) The OK led makes a fast flash if 
the code has been memorised, 
or it makes a slow flash if the 
code is just in memory. 

(If the OK led makes 3 flashes that 
means the memory is full and you 
can’t memorise other codes.) 

 

1 fast flash: 
  
1 slow flash: 

code memorised 
 
code is just in memory 

4) If you want to memorise other 

radio codes SS, you have to 
repeat from point 2 or take off 
the little bridge JA 
 
 

 

 

  

   

 