background image

ASM321 Basic VCO

ELBY Designs - Laurie Biddulph

9 Follan Close, Kariong, NSW 2250, Australia

[email protected]

http://www.elby-designs.com

3 of 3

Calibration

Initially you need to calibrate the ASM VCO Core board and should follow the instructions in the

ASM VCO

Core build notes

.

The remaining calibration process is for setting the wave shaper outputs:-

SAWTOOTH Output

1. Monitor the [SAWTOOTH] output

2. Set the [COARSE] and [FINE] controls so that the output is running at around 100Hz

3. Adjust P201 until the waveform is centred around 0V

TRIANGLE Output

1. Monitor the [TRIANGLE] output

2. Adjust P303 until the output is about 4V pk-pk

3. Adjust P301 for optimum waveshape

4. Adjust P302 until the waveform is centred around 0V

5. Adjust P303 until the output is about 5V pk-pk

6. Repeat steps (3) to (5) for best triangle wave shape

SINE Output

1. Monitor the [SINE] output

2. Adjust P306 until the output is about 4V pk-pk

3. Adjust P305 for optimum symmetry

4. Adjust P304 for optimum waveshape

5. Adjust P306 until the output is 5V pk-pk

6. Repeat steps (3) to (5) for best sine wave shape

Отзывы: