ASM-2 Construction Guide
ELBY Designs - Laurie Biddulph
9 Follan Close, Kariong, NSW 2250, Australia
18 of 19
PSU
There is a pcb error with U3 and U4. Please refer to the
for the correct
installation orientation.
The PCB silkscreen also indicates that the internal reference supplies are 7V, this has
been updated to 9V.
These internal reference supplies, available at J3, are to be used only for the VCOs.
J2 is available for other panel components that require access to the main power rails (+/-
12V)
Power up, Testing and Calibration Procedures
1. Monitor TP2 and adjust P1 (+7V) for +9.0V
2. Monitor TP3 and adjust P2 (-7V) for -9.0V