14
Commands of the list of users enabled to receive SMS alarms
Command
Description
Example
Response
UA:[NUM]#
Add a user to the list
0000#UA: +41798527511#
User added: +41798527511
Free space: 599/600
UD:[NUM]#
Delete a user from the list
0000#UD: +41798527511#
User deleted!
Free space: 600/600
U?
Requests the list of users
0000#U?
List
Temperature sensor calibration commands
Command
Description
Example
Response
TC[±0-9]
Temperature sensor calibration
0000#TC+3
0000#TC-2
SENSOR CALIBRATED!
Nameplate data
Radio
•
UMTS/HSPA/GSM 900Mhz ,1800MHz, 2100Mhz
•
SIM card type Micro-SIM 3FF
Power supply
•
Nominal supply voltage: 5.3÷12V
⎓
•
Current: I
max
= 800mA
•
The device must be powered by a power source limited to 24VA
•
Power supply protected against reverse polarity
Temperature
sensor
•
NTC Thermistor
•
Temperature range: -40 ÷ +150°C
•
Tolerance on R
25
: ±3%
Outputs
•
1 SPDT Form C relay
o
0,5A [EC type-approval], 250V~ (Resistive)
o
Max relay switching 5A
o
1A, 30V
⎓
Inputs
•
1 programmable digital input:
o
voltage contact (0…3-30V
⎓
)
o
clean contact
General charac-
teristics
•
Flammability rating: UL94V-0
•
Degree of protection: IP20
•
Standard operating temperature: da -5°C a +45°C
•
Maximum conductor cross-section that can be inserted into the terminals:
2,5mm
2
•
Mini-USB programming port
Certifications
•
2014/53/EU (RED)
•
2014/30/UE (EMV)
•
2014/35/UE (LVD)
•
FCC/CE/TE- LEC/KCC/SRRC/IC/NCC
Absorption
•
Standby 40mA
•
Sending\receiving SMS 200mA