6
Installatio
n
In order to safeguard the safety and safety of the operator and the correct functioning of the
device, the SMSB121TH device must be installed only and exclusively by a qualified person. The
following standards must also be observed.
Safety information
•
The SMSB121TH incorporates a low power radio transceiver. When in operation by road and receives
radio frequency energy. Operation in the vicinity of radios, televisions, telephones or elec-
tronic devices in general may cause interference. It may also be subject to interference that
may affect its performance.
•
Do not install the SMSB121TH near pacemakers, prostheses or medial equipment in general, as
interference with proper operation of these devices may occur.
•
SMSB121TH shall not be installed on board aircraft.
•
Do not install the SMSB121TH in the presence of flammable gases or fumes.
•
The SMSB121TH operates using a radio signal: no mobile operator can provide a connection at
any time.
Environmental conditions
he SMSB121TH device (the device and all the cables connected to it) must be installed in places
without, or away from, the device:
•
Dust, humidity, high heat;
•
Direct exposure to sunlight;
•
Objects radiating heat;
•
Objects producing a strong electromagnetic field;
•
Liquids or corrosive chemicals.
•
The SMSB121TH has been designed to work at a temperature between -5°C and +45°C (standard
operating temperature).
•
Avoid any rapid change in temperature and/or humidity.
Degree of protection
When installing the SMSB121TH device, the following degree of protection must be ensured:
•
IP40: minimum degree of protection, must always be guaranteed;
•
IP54: degree of protection to be provided for use in outdoor applications.
Power supply
Observe the following standards:
•
Do not use cables longer than 2.9m;
•
The external power supply unit must be class 2 (LPS) certified SMPS (not included)
•
Do not reverse the polarity of the power supply cables.
Digital and analog input
s
Observe the following standards
:
•
Connect only clean contact switches, switches and contactors.
•
if analog only suitable and certified sensors should be connected;
•
Do not use cables longer than 2.9m;
•
Do not connect inputs to power sources.
•
Do not reverse the polarity of cables in analog inputs
.
Relay output
s
•
Refer to the chapter on nameplate data.
•
Do not use cables longer than 2.9m;
•
Connect only one voltage level for all relays: If the load is subjected to pe-recycle voltage,
use only the phase cable.