background image

REBLE610 Fully indoor Microwave Link 

 

Page 27 of 52 

 

Version 1.4

 

 

Figure 42

Receiver menu. 

 
Active areas: 

 

Directional arrow “UP”

 to go back to main menu. 

The page also shows three icons that correspond to the alarm led

 

1.

 

 An alarm for the oscillator status 

2.

 

 An alarm indicating the low field level received for the used modulation. 

3.

 

 An alarm indicating that the temperature of the module is higher than 55°C. 

The page reports as well the measurements of the registered temperature and received field level (RSSI). 

7.8

 

Menu Power Supply (PS). 

The Power Supply menu allows verifying whether both power supply modules are fed, what type of feeding 
they are receiving and whether the secondary voltages are correct (+5V and +6V). 

 

Figure 43: Power Supply menu. 

 
Active areas: 

 

Directional arrow “UP”

 to go back to main menu. 

There is as well a general alarm indicator in case one of the voltage values is not being respected. 
The upper zone of the menu is dynamically filled by the icon of the corresponding power supply module, 
which  can  be  in  alternating  or  continuous current.  It  is  hence  possible to  see  the  different  combinations 
reported in the following figures. 
 

 

Figure 44: Icon power supply with continuous current, 

primary position. 

 

Figure 45: Icon power supply with continuous current, 

secondary position. 

Содержание REBLE610

Страница 1: ...REBLE610 10 08 2015 www elber com elber elber it Page 1 of 52 Version 1 4 REBLE610 User Manual System REBLE610 Fully indoor Microwave Link Release 1 4 Author Simone Canepa...

Страница 2: ...MENU UPROCESSOR UP 13 7 3 1 MicroProcessor submenu 13 7 3 2 Menu Setup System Time 13 7 3 3 Menu Setup Touch Screen Calibration 13 7 3 4 Menu Setup Reset 14 7 3 5 Menu Net Network parameters 14 7 3 6...

Страница 3: ...er Customer 34 8 3 3 Controller Network 35 8 3 4 Controller Trap Manager 36 8 3 5 Controller Tools 38 8 3 6 Controller Password management 39 8 4 TAB SLOT 39 8 4 1 Slot Modem 39 8 4 2 Slot Interface 4...

Страница 4: ...U 20 FIGURE 25 MODEM FD MEASUREMENTS MENU 2 20 FIGURE 26 MODEM TX MEASUREMENTS MENU 2 20 FIGURE 27 MODEM RX MEASUREMENTS MENU 2 20 FIGURE 28 MODEM XPIC MEASUREMENTS MENU FD 21 FIGURE 29 MODEM XPIC MEA...

Страница 5: ...NFIGURATION 37 FIGURE 65 WEB CONTROLLER FORM CONTROLLER SNMP TRAPS CONFIGURATION 37 FIGURE 66 WEB CONTROLLER FORM ALARM RELAY CONFIGURATION 37 FIGURE 67 WEB CONTROLLER FORM TRAP DESTINATION CONFIGURAT...

Страница 6: ...ATURE MANAGEMENT 47 FIGURE 90 WEB UPGRADE FORM CONFIGURATION FILE UPLOADER 48 FIGURE 91 WEB UPGRADE FORM MACHINE UPGRADE 48 FIGURE 92 WEB LOG FORM AVAILABLE LOG 49 FIGURE 93 WEB LOG FORM AVAILABLE LOG...

Страница 7: ...the nostrils attach the mouth to the victim one s and do 4 quick mouth to mouth respirations Figure 1 Resuscitation detail 1 Figure 2 Resuscitation detail 2 Check the pulsation Figure 3 in case of ab...

Страница 8: ...in an hour and the victim is conscious and does not retch give a liquid solution containing salt and sodium bicarbonate 1 teaspoon of salt and half a teaspoon of sodium bicarbonate for each 250 ml of...

Страница 9: ...BNC connectors configurable as input or output this feature let have in a single chassis the functions of an ASI matrix and an ASI distributor both in input and output The link let also transfer IP t...

Страница 10: ...lber s r l parameters cannot be manually modified Table 4 Modulation schemes QPSK 8PSK 16 32 APSK 16 32 64 128 256QAM Protection codes 1 Low Density Parity Check LDPC encoder 2 Reed Solomon with K fro...

Страница 11: ...o the correct power tension reading the information on the manual or on the label attached to each equipment containing the serial number Connect the network cable to the plug on the rear of the equip...

Страница 12: ...eventually red or green depending on the status of the related block Figure 3 Main menu FD Figure 4 Main menu Tx Figure 5 Main menu Rx Active areas Rx Tx Modem uC I O uP PS Bus 7 2 Summary menu Summar...

Страница 13: ...Information about system time is preserved by the battery of the Real Time Clock Figure 8 System time setting menu Active areas Directional arrow UP to go back to main menu Directional arrows LEFT and...

Страница 14: ...uipment Figure 11 Reset menu Active areas Directional arrow UP to go back to main menu Directional arrows LEFT and RIGHT to browse microprocessor menu Reset icons SLOT reset will eventually restart mo...

Страница 15: ...al information 1 2 This menu shows general purpose information such as Model Serial Number Part Number Figure 13 General info menu 1 2 Active areas Directional arrow UP to go back to main menu Directi...

Страница 16: ...enu Misc Modules 7 3 8 1 Menu Misc Modules Controller This menu shows controller general purpose information such as Model Version Revision Figure 15 General purpose information controller Active area...

Страница 17: ...or menu 7 3 8 3 Menu Misc Modules Interfaces This menu shows I O interface general purpose information such as Model Version Revision Figure 17 General purpose I O interface information Active areas D...

Страница 18: ...uch as Model Version Revision Figure 19 General purpose information Tx Active areas Directional arrow UP to go back to main menu Directional arrows LEFT and RIGHT to browse microprocessor menu 7 4 Men...

Страница 19: ...e modem configuration menu let the user change the transmitting profile of the modulator Modifying numeric index in the Profile box related modulation scheme and bitrate are shown XPIC checkbox let th...

Страница 20: ...ging to the temperature or other factors 2 LDPC shows the Bit Error Rate detected by the LDPC decoder 3 AGC indicates the digital automatic gain control level The measurement is not indicative in case...

Страница 21: ...control process AFC is always active to compensate possible RF oscillator drifts due to aging to the temperature or other factors 2 LDPC shows the Bit Error Rate detected by the LDPC decoder 3 AGC in...

Страница 22: ...f 1x10 3 3 MSE Th alarm indicates that the MSE value is below the alarm threshold for the modulation scheme adopted Furthermore there s the temperature alarm that is shared between the two sections an...

Страница 23: ...n by default Normal and Predistorsion checkbox are enabled Figure 34 Modem general menu FD Figure 35 Modem general menu Tx Figure 36 Modem general menu Rx Active areas Directional arrow UP to go back...

Страница 24: ...ernet menu Ethernet menu let the user check the status of Gigabit Ethernet port Figure 38 Menu Ethernet Active areas Directional arrow UP to go back to main menu Display shows following indications an...

Страница 25: ...ctor status A B C D E F G H J K Moreover the display shows following information Tag Type Description I O Text Input I or Output O indication L Led Input signal lock indication valid only for inputs C...

Страница 26: ...detected indication that is the ASI signal presence valid only for inputs 7 6 Menu Transmitter TX The Transmitter menu consists of a single page that allows monitoring and setting of the most importan...

Страница 27: ...Supply menu allows verifying whether both power supply modules are fed what type of feeding they are receiving and whether the secondary voltages are correct 5V and 6V Figure 43 Power Supply menu Act...

Страница 28: ...Web server connection can be achieved through RJ 45 connector in the front panel with a very common Web browser like Internet Explorer Mozilla Firefox Google Chrome Opera Safari it is possible to chec...

Страница 29: ...Customer name Location Installation site Device Equipment configuration Full duplex Tx Rx Repeater From Transmitting site To Receiving site Serial Number Ex REB610 10 00002 2012 Part Number Ex REB610...

Страница 30: ...odem board microcontroller firmware revision Temperature Temperature measurement on modem board Line is green if value is between limits red otherwise Mod Configuration in use Details of the configura...

Страница 31: ...Internal AGC level Line is green if value is between limits red otherwise 8 2 Status Interface Figure 53 Web Status form Interface ASI E1 Table 12 I O Interface status Model Data interface board Model...

Страница 32: ...ure 55 this function management is shown 8 2 1 Status Transmitter Figure 55 Web Status form Tx This form is not available in half duplex configuration receiver version Table 14 Status Transmitter Mode...

Страница 33: ...r board HW version Revision Serial number receiver board Temperature Receiver board temperature measurement Line is green if value is between limits red otherwise Frequency Receiving circuit operating...

Страница 34: ...the user Right fan is managed according to transmitter board temperature if installed so not available in half duplex receiver configuration left fan according to temperatures detected on modem and r...

Страница 35: ...to Site which the equipment is transmitting to 8 3 3 Controller Network Figure 59 Web Controller form Network Parameters This frame let check and modify network parameters of the user interface Ip Ad...

Страница 36: ...is possible to enable or disable the traps sending Besides it is possible to set their destination address Figure 60 Web Controller form Modem SNMP traps configuration Figure 61 Web Controller form Da...

Страница 37: ...on 1 4 Figure 64 Web Controller form Transmitter SNMP traps configuration Figure 65 Web Controller form Controller SNMP traps configuration Figure 66 Web controller form Alarm Relay configuration Figu...

Страница 38: ...arately i e the modem microcontroller the system controller the whole system or to TFT calibration USB Token subsection let the user generate a single use password to be installed on a USB drive which...

Страница 39: ...password level that can be modified is subject to the rights of the user The user User cannot change passwords User Super User can change its own and the User ones The Administrator can change any pa...

Страница 40: ...igure 70 Web slot modem form status Status frame reports the information already shown in the homepage of the web interface see par 8 1 2 Figure 71 Web slot modem form MSE Graphic MSE Graphic frame re...

Страница 41: ...et and check alarm and warning thresholds through the interactive bar and the Apply button and the actual temperature Figure 73 Web slot modem form Profile management Figure 74 Web slot modem form Pro...

Страница 42: ...perational Mode Management expanded Operational Mode Management frame let the user modify some modem parameters Operational Mode o Normal o Clean carrier generator for dish aligning o Two tones genera...

Страница 43: ...ace form Status Status frame reports information already shown in the homepage see par 8 2 Figure 78 Web slot interface form Input Output ports management Input output port management frame let the us...

Страница 44: ...et the user configure the signals coming from demodulation section that can be forwarded to the modulator section in case of a repeater configuration Every transport channel present in the data stream...

Страница 45: ...duplex mode and port speed If auto negotiation is enabled Full Duplex and Speed are not available 8 4 3 Slot TX Web section of transmitter board is composed by 4 frames 1 Status 2 Temperature Managem...

Страница 46: ...er part of the frame and measured in dBm can be adjusted in a 2 to 2 dB range from the calibration value It is possible to mute the transmitter by clicking on the related switch in the right part of t...

Страница 47: ...r frequency depending on the factory limits shown in the interactive bar by default it is possible to modify the frequency in a 5 MHz range channel filter is generally installed Figure 89 Web slot Rx...

Страница 48: ...user select a modem configuration remove it from database upload a new one and check the stored ones Figure 91 Web Upgrade form Machine Upgrade This frame let the user upload equipment software upgrad...

Страница 49: ...sing Erase until form and selecting desired interval Figure 93 In central part of the page log messages are reported organized in a table that can be ordered filtered and resized in terms of number of...

Страница 50: ...REBLE610 Fully indoor Microwave Link Page 50 of 52 Version 1 4 Figure 94 Web Log form log Figure 95 Web Log form filters...

Страница 51: ...token connection for TFT access 4 Green led Power supply 5 Three colors led Green ok Yellow warning Red alarm 6 Display TFT touchscreen User interface needs token to access 7 Connector SMA f 75 Ohm I...

Страница 52: ...on 11 Connector BNC 75 Ohm In out ASI J software configuration 12 Connector BNC 75 Ohm In out ASI K E1 OUT software configuration 13 Connector RJ 45 Link for 1 1 configuration with paired REBLE610 for...

Отзывы: