2. According to the hanging board, drill 12 pcs of ST6 * 40mm
flat screws that will be used to fix the hanging board onto the
ceiling as seen in pic 2.
3. Then, 8 pcs of M4*10 screws and M4 nuts with gaskets will
be used to connect the angular bar into the hanging board
mounted on the ceiling as seen in pic 2.
4. If the height is not enough to meet the minimum
requirements, an additional section can be added to lower
the body of the range hood.
5. Calculate the length of the angle bar, and use 16 pcs M4*10
flat screws and M4 nuts with gaskets to connect another
angular bar with the first section.
*Note: The overlap length of angular bar should be at least
100mm to maintain rigidity and stability of the lower section.
6. Make sure that the exhaust pipe is fitted inside the 170mm
opening as seen in pic 3.
7. Use 4 pcs ST4*8 flat screws to connect the upper/internal
chimney onto the hanging board, then put the external
chimney. Two (2) hooks will be used to hold up the chimney
in order to install the lower sections, as seen in pic 4.
8. Use 4 pcs ST4*8 flat screws to install the outlet on the body
casing, as seen in pic 5.
9. Affix the glass portion on the body of the range hood by
using the supplied hardware. Use the 4 screws and check
whether the glass and the body of the range hood fits well,
as seen in pic 6.