Elba EGH-A9241GX Скачать руководство пользователя страница 12

 

ELECTRICAL CONNECTION 

The  appliance  is  profited  to  operate  with  a 
power supply voltage of 230Vsingle-phase. The 
connection  must  be  made  in  accordance  with 
the regulations and laws in force. 
Before making the connection, make sure that: 
1)  the  safety  circuit-breaker  and  the  electrical 

system are able to withstand the load of the 
appliance(see nameplate). 

2)  The  power  supply  system  has  an  earth 

connection  in  good  working  order  in 
accordance with the regulations in force; 

3)  The  socket  or  omni  polar  switch  use  are 

easily 

accessible 

with 

the 

appliance 

installed. 

Fit a plug suitable for the load on the power lead 
and connect it to a suitable safety socket. 
If you wish to make a direct connection to the mains, an omni polar switch with 
a gap between the contacts of at least 3 mm, of suitable rating for the load and 
complying  with  the  regulations  in  force,  must  be  installed  between  the 
appliance  and  the  mains.  The  switch  must  not  break  a  contact  in  the 
yellow/green earth wire. 
The brown live wire (connected to the “L” terminal of the terminal board) must 
always be connected to the live wire of the power supply mains. 
In  all  cases,  the  power  supply  lead  must  be  positioned  so  that  it  does  not 
reach a temperature 50

o

C above the room temperature at any point. 

One example of an ideal route is shown in the illustration. The cable is guided 
by means of band clamps fixed to the side of the cabinet, in order to avoid any 
contact with the appliance underneath the hob.   
 

REPLACING THE POWER SUPPLY LEAD 

If  the  lead  has  to  be  replaced,  only  HO5RR-F  or 
HO5RN-F  type  cables  suitable  for  the  load and the 
operating temperature must be used. In addition, the 
yellow/green  earth  wire  must  be  about  2  cm  longer 
than the live and neutral wires.   
 

                                                                                                                                   

11 

Содержание EGH-A9241GX

Страница 1: ...se read this manual carefully before operating your set Retain it for future reference Record model number and serial number of the set See the label attached on the set and quote this information to...

Страница 2: ...h the accident prevention regulations Make sure that air is able to circulate freely around the appliance Poor ventilation produced a shortage of oxygen Make sure that the appliance is supplied with t...

Страница 3: ...ANING AND MAINTENANCE Keep the appliance thoroughly cleaned Food residues may cause fire risks SERVICE AND PARTS In the instance of malfunctions Never attempt to repair the appliance yourself Repairs...

Страница 4: ...fitted kitchen units 13 Guide to reading the instructions The following symbols will help you When reading the instructions Safety information Step by step instructions Suggestions and Advice Informa...

Страница 5: ...ximum gas flow Minimum gas flow All operating positions must be set between the maximum and minimum flow settings and never between the maximum setting and the closed position Symbol present on versio...

Страница 6: ...flame near the burner and proceed as already described If the flame does not light after a few attempts check that the burner cap and flame cap are correctly positioned To turn off the flame turn the...

Страница 7: ...rm water and a little liquid detergent Do not use the following products household detergents or bleaches soaped scouring pads not suitable for non stick utensils steel wool scouring pads stain remove...

Страница 8: ...who sold you the appliance or our nearest Service Centre specifying the nature of the problem the model of the equipment Mod the product number Prod No and the serial number Ser No These data are pro...

Страница 9: ...0 362 0 98 277 0 77 277 Gas intake connection G1 2 Electricity supply 220 240v 50 60Hz INSTRUCTIONS FOR THE INSTALLATION TECHNICIAN CAUTION This appliance must only be installed and used in rooms wit...

Страница 10: ...iance is installed the necessary air may be taken from an adjacent room provided that this room is not a bedroom or a hazardous environment this room has ventilation the ventilation between the room w...

Страница 11: ...ion must be fitted on the end of the gas train Complete with GJ1 2 threaded nut fitting the gasket between the components as shown in the illustration The gaskets must comply with the local standards...

Страница 12: ...at least 3 mm of suitable rating for the load and complying with the regulations in force must be installed between the appliance and the mains The switch must not break a contact in the yellow green...

Страница 13: ...ied or variable a suitable piped gas pressure regulator complying with the standard must be installed on the supply pipeline Setting the minimum level 1 Light the burner as already described 2 Turn th...

Страница 14: ...n the installation opening place the special gasket around the bottom edge of the hob It is important to fix this gasket evenly without gaps or overlapping to prevent liquid from seeping underneath th...

Страница 15: ...be locked in position and released in case of servicing work On base cabinet with oven The installation compartment must have the dimensions shown in figures 2 and 3 and must have supports to allow s...

Страница 16: ...FICATION Gas Source LPG Rated Gas Pressure 2 800 Pa Burner Rating 3 8kW Left 3 8kW Right 1 75kW Middle Only applicable to 3 burner model Built in Dimension mm 750 W x 470 D Product Dimension mm 860 W...

Страница 17: ......

Отзывы: