20
ADjUSTMENT OF THE EXTERNAL
GAS REGULATOR (TOWN GAS)
For Town Gas (TG) installation, external
gas pressure regulator
must be installed.
The TG regulator (provided with the
appliance) has the specifications as per
Fig. 2.6.
To regulate the external gas pressure
regulator, it is necessary to follow the
following steps:
1.
Connect the gas regulator to the
appliance (arrow up) and the other end
to the town gas flexible hose (refer to
the chapter “GAS CONNECTION fOR
TOWN GAS ONLY” and to fig. 2.3).
2. Remove the screw from the test point.
Make sure that the rubber gasket is
intact with the screw when removing.
3. Adjust the pressure by using the gas
test gauge (U-gauge).
Connect the U-gauge to the test point
with tube hose (refer to Fig. 2.7).
Turn on the gas burner (the biggest
burner) to the maximum power and
adjust the pressure to 8 mbar by using
the adjustable screw.
4. After setting is completed, lock the
pressure (8 mbar) by tightening the
locking nut and re-mount the test point
screw (make sure that the rubber
gasket is intact with the screw).
5. Perform gas leak test after installation
is completed (using a soapy solution,
but never a naked flame).
Details of the regulator:
MDG ELITRE GVN-01
•
Model number: EL-12550 (EL-125)
•
Gas inlet/outlet connection: ½ inch
BSP internal thread
•
Maximum inlet pressure: 50 mbar
•
Regulated nominal outlet pressure:
8 mbar
Fig. 2.6
Fig. 2.7
Test point
Make sure
that the rubber
gasket is intact
with the screw
Adjustable
screw
Locking
nut
Содержание DOMINO E35-200 XD
Страница 6: ...6 ADVICE for the INSTALLER...
Страница 23: ...23 ADVICE for the USERS...
Страница 30: ...30 Fig 3 1 Fig 3 2 Fig 3 3 Fig 3 4 Fig 3 5 S F C T A B S T...
Страница 31: ...31...