3
3. In order to get the optimum performance, do not elongate the exhaust
pipe too long, and try to make the bend of exhaust pipe less and biggest,
ensure the connection is airproof.(Fig. 3)
4. After hanging the unit on the wall, ensure the hood is level and vertical.
(Fig. 4)
5. The air outlet must not be connected to chimney flues or combustion gas
ducts. The air outlet must under no circumstances be connected to venti-
lation ducts for room in which fuel-burning appliances are installed.
LEVEL
Fig.1
Fig.2
Fig.3
Fig.4
LEAN
INSTALLATION PROCEDURES
SAFETY WARNING
HOOD MAY HAVE VERY SHARP EDGES;PLEASE WEAR
PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY
PARTS FOR INSTALLING, CLEANING OR SERVICING.
6
OPERATION INSTRUCTION
A: Timer: 1.When the hood is working, touch this button one time, the hood will
work for 1 minute, after 1 minute, it will turn off automatically, touch
each one more time can add 1 minute, the longest time you can set is 60
minutes.
2.When the hood is non-working, touch this button 3 seconds, you can
use "Lighting" and "Speed" button to set time like a clock, "Lighting"
can set hour, "Speed" can set minute.
B: Lighting: Touch this button one time, the lamp will be lighted; Touch again, the
lamp will extinguish.
C:Speed: Touch this button, the motor works in high speed, touch this button again,
the middle speed runs; touch the button thrice, the low speed runs; the
motor stops after touching it quartic.
D: On/Off: This general On/Off button, touch this button first before you touch
other buttons; touch this button when the hood is working, the motor
stops running, lights turn off.
A
B
C
D
①
②
Step 9:
Charcoal Filer
Install: First step, take out the flat filter,
put the charcoal filter near the blower box,
press charcoal filter clip to ward the direc
-tion of arrow
. then make the charcoal
filter connect blower box tightly.
Remove: Take out the flat filter, press
charcoal filter clip and pull out toward
the direction of arrow
.
①
②
Clip
文件使用
"pdfFactory"
试用版本创建
www.fineprint.cn