6
(Note: This step will prevent damage to the heating element).
SAFETY PRECAUTION
Do not install reverse INLET and OUTLET of heater
INLET
OUTLET
OUTLET
OUTLET
correct installation
inlet - outlet reverse
(wrong installation)
stop valve reverse
(wrong installation)
INLET
Stop
Valve
Stop
Valve
Stop
Valve
INLET
6. Electrical Connection
a)
Insert electrical cable through the rubber grommet as shown.
b)
Connect the cable to the terminal block and fully tighten them
as the following:-
• Red or Brown ……………………………….……… Live (L)
• Black or Blue.…………………………………… Neutral (N)
• Green or Green/Yellow……………………………Earth
c)
Restore the cover and secure screw at the bottom. ( Diagram 4)
d)
Align the knob from ‘ON’ position in clockwise direction to ‘MAX’
and return to ‘OFF’ mark as shown. (Diagram 5)
Diagram 5
Diagram 4
Restore cover
Содержание ACQUA Series