background image

 

 

w w w . e l a t i o n l i g h t i n g . c o m  

 

                                              

14

                         ZCL BAR Z300 IP™ User Manual

 

S Y S T E M   M E N U  

The fixture includes an easy to navigate system menu control panel display where all 
necessary setting adjustments  are made.  (See image below) During normal 
operation, pressing the 

MODE

 button once will access the main menu. Once in the 

main menu you can navigate through the different functions and access sub-menus 
with the 

UP 

and 

DOWN 

buttons. Once you reach a field that requires adjusting, press 

the 

ENTER

 button to activate that field and use the 

UP

 and 

DOWN

 buttons to adjust 

the field. Pressing the 

ENTER 

button once more will confirm your setting. You may exit 

the main menu at any time without making any adjustments by pressing the 

MODE/ESC

 button. 

LCD CONTROL PANEL LOCKOUT FEATURE 

When the 

Key Lock

  menu (

Function | LCD. Set | Key Lock

) is set to 

ON 

(default 

setting), the LCD control panel display will turn OFF and become LOCKED after 

non-use. To UNLOCK, press the 

MODE

 button. 

 

When the 

Key Lock

 menu is set to 

ON1

 mode, follow these steps to UNLOCK the LCD display: 

 

1.

 

When locked, the display will show: 

LOCKED*****

 

2.

 

Press 

UP

, then the display will change to: 

LOCKED****

 (one * disappears) 

3.

 

Press 

DOWN

, then the display will change to: 

LOCKED***

 (two * disappear) 

4.

 

Press 

UP

, then the display will change to: 

LOCKED**

 (three * disappear) 

5.

 

Press 

DOWN

, then the display will change to: 

LOCKED*

 (4 * disappear) 

6.

 

Press 

ENTER

, then the display will change to 

LOCKED

 and then become unlocked. 

 

INFORMATION DISPLAYED DURING INITIAL POWER ON 

When the fixture is initially powered ON, the display shows the following information: 

 

Update Wait... 

ZOOM   

Reset... 

ELATION 

V1.01 

ZCL Bar 

Z300 IP 

Содержание ZCL BAR Z300 IP

Страница 1: ...ZCL BAR Z300 IP user manual E L A TI ON ZCL BAR Z300 IP user manual...

Страница 2: ...LATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic...

Страница 3: ...P User Manual C O N T E N T S General Information 4 Warranty 7 Safety Instructions and Guidelines 8 Overview 10 Installation 11 System Menu 14 DMX Channel Functions And Values 17 Cleaning and Maintena...

Страница 4: ...t particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been design...

Страница 5: ...first contacting customer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS 1 powerCON TRUE1 Cable CUSTOMER SUPPO...

Страница 6: ...in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package will...

Страница 7: ...er by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this wa...

Страница 8: ...mega brackets included with this fixture should be used for installation Any modifications to the fixture and or the mounting hardware included will void the original manufactures warranty and increas...

Страница 9: ...wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always install fixture with an appropriately rated safety...

Страница 10: ...w w w e l a t i o n l i g h t i n g c o m 10 ZCL BAR Z300 IP User Manual O V E R V I E W SAFETY CABLE RIGGING POINTS...

Страница 11: ...LECTRICAL SUPPLIERS TO PREVENT WATER CORROSION AND OR ELECTRICAL SHORT CIRCUIT For added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personn...

Страница 12: ...ng points integrated in the fixture RIGGING Overhead rigging requires extensive experience including amongst others calculating working load limits installation material being used and periodic safety...

Страница 13: ...KING Max number of ZCL BAR Z300 IP units power linked together 2 units 120V 5 units 240V NOTE USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO ZCL BAR Z300 IP POWER CONSUMPTION OF OTHER LIGHTING FIXTU...

Страница 14: ...ts by pressing the MODE ESC button LCD CONTROL PANEL LOCKOUT FEATURE When the Key Lock menu Function LCD Set Key Lock is set to ON default setting the LCD control panel display will turn OFF and becom...

Страница 15: ...ASH 10 FLOW5 SP 01 99 F 00 99 Internal Prog 10 Adjust SPEED and FLASH 11 FLOW6 SP 01 99 F 00 99 Internal Prog 11 Adjust SPEED and FLASH 12 FLOW7 SP 01 99 F 00 99 Internal Prog 12 Adjust SPEED and FLAS...

Страница 16: ...anual Function DimCurve Select desired DIMMER MODE Standard Stage TV Architectural Theatre Flip Select the desired starting LED and chase direction from one of the following modes below via UP DOWN bu...

Страница 17: ...Pan Tilt settings MODE CHANNEL VALUE FUNCTION CH 05 CH 06 CH 07 CH 09 CH 12 CH 21 CH 28 1 1 1 1 1 0 255 RED ALL LEDs 0 to 100 2 2 2 2 2 0 255 GREEN ALL LEDs 0 to 100 3 3 3 3 3 0 255 BLUE ALL LEDs 0 to...

Страница 18: ...21 CH 28 13 13 0 255 RED LED 4 0 to 100 14 14 0 255 GREEN LED 4 0 to 100 15 15 0 255 BLUE LED 4 0 to 100 16 16 0 255 WHITE LED 4 0 to 100 17 17 0 255 RED LED 5 0 to 100 18 18 0 255 GREEN LED 5 0 to 1...

Страница 19: ...13 16 COLOR PRESET 04 17 20 COLOR PRESET 05 21 24 COLOR PRESET 06 25 28 COLOR PRESET 07 29 32 COLOR PRESET 08 33 36 COLOR PRESET 09 37 40 COLOR PRESET 10 41 44 COLOR PRESET 11 45 48 COLOR PRESET 12 4...

Страница 20: ...PRESET 36 145 148 COLOR PRESET 37 149 152 COLOR PRESET 38 153 156 COLOR PRESET 39 157 160 COLOR PRESET 40 161 164 COLOR PRESET 41 165 168 COLOR PRESET 42 169 172 COLOR PRESET 43 173 176 COLOR PRESET...

Страница 21: ...O FUNCTION 1 20 PROGRAM MACRO 01 21 40 PROGRAM MACRO 02 41 60 PROGRAM MACRO 03 61 80 PROGRAM MACRO 04 81 100 PROGRAM MACRO 05 101 120 PROGRAM MACRO 06 121 140 PROGRAM MACRO 07 141 160 PROGRAM MACRO 08...

Страница 22: ...efer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points...

Страница 23: ...lor Presets and 12 Unique Program Macros Electronic Strobe and Selectable Dimming Curves CONTROL CONNECTIONS 7 DMX Channel Modes 28 Total Channels 4 Touch Button Control Panel and LCD Menu Display RDM...

Страница 24: ...031 374 2 471 230 1 666 155 1 179 110 928 86 WHITE LEDs 24 311 2 258 20 111 1 868 11 640 1 081 8 523 792 6 602 613 FULL ON 63 777 5 925 36 436 3 385 24 372 2 264 16 725 1 554 12 872 1 196 MAX ZOOM 44...

Страница 25: ...design of this unit and this manual are subject to change without any prior written notice O P T I O N A L A C C E S S O R I E S ORDER CODE ITEM NARROW CLAMP PRO 2 Wrap Around Clamp 8050000053 Omega B...

Страница 26: ......

Отзывы: