Elation TVL3000-II CW Скачать руководство пользователя страница 10

©Elation Professionals®  -  www.elationlighting.com  - TVL3000-II WW/CW/DW User Manual Page 19

  TVL3000-II WW/CW/DW                                        Cleaning

  TVL3000-II WW/CW/DW                           Trouble Shooting

Trouble Shooting: Listed below are a few common problems that 

you may encounter, with solutions.
1. The unit does not work, no light and the fan does not work

 - Check the power connection on both the unit and power source.

2. Not responding to DMX controller

 - DMX LED should be on. If not, check DMX connectors and cables  

   make sure they are linked properly.

 - If the DMX LED is on and no response to the channel, check the  

   address settings

 - If you have intermittent DMX signal problems, check the pins on  

   connectors.

 - Try to using another DMX controller.

 - Check if the DMX cables run near or run alongside high voltage  

   cables that may cause damage or interference to DMX interface 

   cir cuit.

Fixture Cleaning:

 Due to fog residue, smoke, and dust cleaning 

the internal and external optical lenses and mirror should be carried 

out periodically to optimize light output. Cleaning frequency depends 

on  the  environment  in  which  the  fixture  operates  (I.e.  smoke,  fog 

residue, dust, dew). In heavy club use we recommend cleaning on a 

monthly basis. Periodic cleaning will ensure longevity, and crisp out-

put.
1.  Use normal glass cleaner and a soft cloth to wipe down the out- 

  side casing.

2.   Use a brush to wipe down the cooling vents and fan grill.

3.   Clean the external optics and mirror with glass cleaner and a soft  

  cloth every 20 days.

4.   Clean the internal optics with glass cleaner and a soft cloth every  

  30-60 days.

5.  Always be sure to dry all parts completely before plugging the unit  

  back in.

 TVL3000-II WW/CW/DW                          Photometric Chart

©Elation Professionals®  -  www.elationlighting.com  - TVL3000-II WW/CW/DW User Manual Page 20

Содержание TVL3000-II CW

Страница 1: ...he TVL3000 II WW TVL3000 II CW have 1 DMX channel while the TVL3000 II DW has 2 DMX channel modes Mode 1 is 2 DMX Channels and Mode 2 is 2 DMX Channels These fixture s have two operating modes manual...

Страница 2: ...rmance TVL3000 II WW CW DW Safety Precautions Elation Professionals www elationlighting com TVL3000 II WW CW DW User Manual Page 4 Elation Professionals www elationlighting com TVL3000 II WW CW DW Use...

Страница 3: ...approved DMX 512 110 Ohm Data cable for data input and data output We recom mend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable...

Страница 4: ...may be implemented in a 3 pin XLR DMX line When inserting stan dard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores Th...

Страница 5: ...ress ENTER Either Yes or No will be displayed 2 To activate Blackout press the UP or DOWN buttons until Yes is displayed press ENTER to confim The fixture will now be in Blackout mode To deactivate Bl...

Страница 6: ...oftware version of the unit 1 Press the MENU button until VER is displayed press ENTER 2 The display will show the software version Press MENU to exit TVL3000 II WW CW DW System Menu TVL3000 II WW CW...

Страница 7: ...is displayed press ENTER 2 Press the UP or DOWN buttons to scroll through the different color temperatures Once you have found your desired color temperature press ENTER to confirm then press and hold...

Страница 8: ...MENU button until DIMM is displayed and press ENTER 2 Use the UP and DOWN buttons to adjust the intensity until you reach your desired intensity 3 Once you have found your desired intenstiy press ENTE...

Страница 9: ...II WW CW DW Installation The unit should be mounted using a mounting clamp not provided affixing it to the mounting bracket that is provided with the unit Always ensure that the unit is firmly fixed t...

Страница 10: ...may cause damage or interference to DMX interface circuit Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out periodic...

Страница 11: ...odic check up During the period specified above Ela tion Professionals will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defec...

Страница 12: ...W II Cool Warm White DMX TVL3000WW II 1 DMX Channel TVL3000CW II 1 DMX Channel TVL3000DW II 2 DMX Channel Modes 2 DMX Channels 2 DMX Channels Working Position Any Safe Secure Position Warranty 2 Year...

Отзывы: