w w w . e l a t i o n l i g h t i n g . c o m
w w w . e l a t i o n l i g h t i n g . c o m
18
SNIPER PRO™ User Manual
LAMP HOURS RESET PROCEDURE
1.
Access the main menu by pressing the
MENU
button and then pressing the
UP
or
DOWN
buttons until
“LAMP TIME”
is displayed.
2.
Press the
ENTER
button and then press the
UP
or
DOWN
to until
“Clearn”
is displayed.
3.
Press the
ENTER
button to clear the lamp timer.
4.
Press the
MENU
button to exit and return to the home screen.
LAMP OPTIMIZATION
Unlike traditional discharge lamps the
Phillips
™
Platinum 14R Lamp
does
NOT
require
optimization. The lamp orientation and optimization procedure has been preset
during the manufacturing process of the lamp. Please remember the
Phillips
™
Platinum 14R Lamp
is
NOT
a hot-restrike lamp therefore, therefore you must wait
approximately
15 minutes
before you can attempt to restrike the lamp once it has
been turned off.