w w w . e l a t i o n l i g h t i n g . c o m
11
RAYZOR BEAM 2R™ User Manual Ver. 1
L A M P I N S T A L L A T I O N I N S T R U C T I O N S
L A M P R E P L A C E M E N T
Please note that due to the nature of the Phillips™ Platinum 2R
Lamp and the optical path of the Elation RAYZOR BEAM 2R
fixture, the lamp MUST BE replaced at 6,000 hours.
Use only Genuine Original Phillips™ Platinum 2R Lamps. Other
brand lamps may cause damage and void warranty!
INSTALLING OR REPLACING THE LAMP
To ensure a proper/safe lamp change, carefully read all the following instructions.
LAMP PROTECTION CIRCUITRY
Because of the nature of the extreme heat associated with the
Phillips™
Platinum 2R
lamp and the tight nature of the internal optical system, it is
IMPERATIVE
that the
lamp be replaced every
6,000 Hours
. This is done to protect the internal optical
system as well as prevent accidental lamp explosion, which could lead to hot glass
particles falling from the fixture.
FAILURE TO CHANGE THE LAMP WITHIN 300 HOUR of the 6,000 HOUR RATED
LIFE, WILL CAUSE THE FIXTURE TO AUTOMATICALLY SHUT DOWN!
At
6,000 Hours
the LCD control display will begin to flash,
“Replace The Lamp”
and
the lamp will flicker for the first five minutes of operation. At this point the lamp has
reached the maximum rated life and should be replaced immediately. After the
lamp has flickered for about five minutes it should strike normally allowing the fixture
to be used temporarily until a replacement lamp can be installed. The fixture will
continue to operate for an additional 300 hours, however the
“Replace the Lamp”
warning will continue to flash in the display. Keep in mind that the flicker protection
circuitry will only work for about 300 Hours (lamp clock life of 6,000-6,300 Hours).
After 6,300 Hours
the fixture will no longer respond to DMX commands and
immediately enter a hibernation mode that will electronically discontinue all fixture
functionality with the exception of a few menu commands. The fixture will continue
to enter hibernation mode until the lamp is replaced and the lamp clock has been
reset. To replace the lamp follow the safety guidelines and procedures listed on the
next page.