background image

 
 

w w w . e l a t i o n l i g h t i n g . c o m  

 

                                                                                              11

                             

RAYZOR BEAM 2R™ User Manual Ver. 1 

L A M P   I N S T A L L A T I O N   I N S T R U C T I O N S  

 

L A M P   R E P L A C E M E N T  

Please note that due to the nature of the Phillips™ Platinum 2R 
Lamp  and  the  optical  path  of  the  Elation  RAYZOR  BEAM  2R 
fixture, the lamp MUST BE replaced at 6,000 hours. 

Use only Genuine Original Phillips™ Platinum 2R Lamps. Other 
brand lamps may cause damage and void warranty!

 

INSTALLING OR REPLACING THE LAMP 

To ensure a proper/safe lamp change, carefully read all the following instructions. 

LAMP PROTECTION CIRCUITRY 

Because of the nature of the extreme heat associated with the 

Phillips™

 

Platinum 2R

 

lamp  and  the  tight  nature  of  the  internal  optical  system,  it  is 

IMPERATIVE

  that  the 

lamp  be  replaced  every 

6,000  Hours

.  This  is  done  to  protect  the  internal  optical 

system as well as prevent accidental lamp explosion, which could lead to hot glass 
particles falling from the fixture. 

FAILURE  TO  CHANGE  THE  LAMP  WITHIN  300  HOUR  of  the  6,000  HOUR  RATED 

LIFE, WILL CAUSE THE FIXTURE TO AUTOMATICALLY SHUT DOWN!   

At 

6,000  Hours

 the LCD control display will begin to flash, 

“Replace  The  Lamp”

 and 

the lamp will flicker for the first five minutes of operation. At this point the lamp has 

reached  the  maximum  rated  life  and  should  be  replaced  immediately.  After  the 
lamp has flickered for about five minutes it should strike normally allowing the fixture 

to  be  used  temporarily  until  a  replacement  lamp  can  be  installed.  The  fixture  will 
continue to operate for an additional 300 hours, however the 

“Replace  the  Lamp”

 

warning will continue to flash in the display. Keep in mind that the flicker protection 
circuitry will only work for about 300 Hours (lamp clock life of 6,000-6,300 Hours).   

After  6,300  Hours 

the  fixture  will  no  longer  respond  to  DMX  commands  and 

immediately enter a hibernation mode that will electronically discontinue all fixture 

functionality with the exception of a few menu commands. The fixture will continue 
to enter hibernation mode until the lamp is replaced and the lamp clock has been 

reset. To replace the lamp follow the safety guidelines and procedures listed on the 
next page. 

 

 

 

Содержание RAYZOR BEAM 2R

Страница 1: ...RAYZOR BEAM 2R user manual E L A TI ON RAYZOR BEAM 2R user manual...

Страница 2: ...ve companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indi...

Страница 3: ...nty 6 Safety Instructions 7 General Guidelines 8 Discharge Lamp Warning 9 Fixture Overview 10 Lamp Installation Instructions 11 Fixture Installation 18 Understanding DMX 21 Fixture Menu 25 DMX Channel...

Страница 4: ...ng the RAYZOR BEAM 2R by Elation Professional Every RAYZOR BEAM 2R has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that ma...

Страница 5: ...under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the pr...

Страница 6: ...aser by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this...

Страница 7: ...described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for i...

Страница 8: ...re must be installed in a location with adequate ventilation at least 1 5 feet 5m from adjacent surfaces Be sure no air ventilation slots are blocked DO NOT attempt installation and or operation witho...

Страница 9: ...the lamp the lamp MAY EXPLODE DURING PROLONGED EXTENSIVE USE This risk is increased with age added care is encouraged when dealing with older lamps Thus the lamp must always be replaced at the end of...

Страница 10: ...F I X T U R E O V E R V I E W 1 LENS 2 LCD Menu Function Display 3 Microphone 4 LEFT Button 5 DOWN Button 6 ENTER Button 7 RIGHT Button 8 MODE ESC Button 9 UP Button 10 Carrying Handle s 11 Lamp Acce...

Страница 11: ...THIN 300 HOUR of the 6 000 HOUR RATED LIFE WILL CAUSE THE FIXTURE TO AUTOMATICALLY SHUT DOWN At 6 000 Hours the LCD control display will begin to flash Replace The Lamp and the lamp will flicker for t...

Страница 12: ...hands will shorten the life of the lamp Always disconnect the fixture s main power supply before replacing lamp Allow fixture to cool for at least 15 minutes before attempting any type of service Mak...

Страница 13: ...AYZOR BEAM 2R User Manual Ver 1 2 Gently remove 2 Red Wires connected to spade terminals on base of lamp 3 Using your thumb and index finger gently squeeze the retention clips together in the directio...

Страница 14: ...w e l a t i o n l i g h t i n g c o m 14 RAYZOR BEAM 2R User Manual Ver 1 4 Move the retention clips in the direction illustrated by the RED ARROW 5 Gently remove the lamp out and away from the fixtu...

Страница 15: ...an cloth or gloves gently install the new lamp into the fixture making sure the lamp is seated correctly straight and flush against the base 7 Using your thumb and index finger gently squeeze the rete...

Страница 16: ...screws marked A B and C 10 Be sure to reset the LAMP HOURS in the system menu to prevent the protection circuitry from accidently shutting off the lamp during normal operation 11 If the lamp protectio...

Страница 17: ...evert to L Timer Password next press UP or DOWN to toggle down to Clear Lamp Time 4 Press ENTER and select ON The lamp timer has now been reset press MODE ESC to exit the menu and return to the home s...

Страница 18: ...ure Ambient operating temperature range for this fixture is 14 to 113 F 10 to 45 C Do not use the fixture under or above this temperature Before mounting the fixture to any surface make sure the insta...

Страница 19: ...iodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture...

Страница 20: ...cluded omega bracket using a M10 screw fitted through the center hole of the Omega Bracket Be sure to attach the included Safety Cable to the fixture using the safety cable rigging point integrated in...

Страница 21: ...line with a Y style connector The order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a starting DMX address of 1 may be placed...

Страница 22: ...rovided XLR cable to the female XLR output of your controller and the other side to the male XLR input of the RAYZOR BEAM 2R The diagram below illustrates a typical DMX 512 connection when the fixture...

Страница 23: ...and DATA This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line Using a line terminator will decrease the possibilities of erratic behavior...

Страница 24: ...ill start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selec...

Страница 25: ...make all necessary adjustments to the RAYZOR BEAM 2R During normal operation pressing MODE ESC button once will access the fixture s main menu Once in the main menu you can navigate through the differ...

Страница 26: ...OFF ON OFF ON OFF 20 79 C 45 C 68 174 F 113 F 80 139 C 130 C 176 282 F 266 F Lamp on off Lamp on off Power on Lamp on via DMX Lamp off via DMX Lamp restart at temp Lamp off at temp Personality Status...

Страница 27: ...run Edit Program Program 1 Program 10 Program Test Step 01 SCxxx Step 64 SCxxx Testing program Program in loop Save and exit Edit Scenes Edit Scene 001 Edit Scene 250 Pan Tilt Fade Time Secne Time In...

Страница 28: ...Displays lamp run time from the last power ON This counter is automatically reset after each time the lamp is powered ON INFORMATION Time Information LastRun Password Display the fixture timer passwo...

Страница 29: ...internal operating temperature of the fixture head when the lamp will automatically be shut OFF PERSONALITY Status Settings Address Via DMX When ON define the desired DMX address via an external cont...

Страница 30: ...TY Status Settings Mic Sensitivity Select desired Microphone Sensitivity PERSONALITY Status Settings Hibernation Select desired Hibernation time PERSONALITY Service Setting Password Displays the servi...

Страница 31: ...ition RESET FUNCTION Reset Shutter Reset only blackout Shutter to Home Position RESET FUNCTION Reset Others Reset ALL other motors not associated previously listed commands to Home Position EFFECT ADJ...

Страница 32: ...by step instructions USER MODE SET User Mode Select operating mode which includes DMX Channel and User defined modes USER MODE SET Edit User Mode Create user defined channel orders allowing the fixtu...

Страница 33: ...signed to If e g a Slave unit is set to Slave 1 in the menu Set to Slave the Master unit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Auto Program Part 2 To st...

Страница 34: ...e program as the master units Press ENTER to confirm Press MODE ESC in order to return to the main menu 4 Program Selection for Edit Program Select Edit Program Press ENTER to confirm Select Edit Prog...

Страница 35: ...ram 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes scenes 12 13 14 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 The 3 Sl...

Страница 36: ...TEND 1 1 1 PAN MOVEMENT 8 BIT 0 255 PAN Movement By 540 630 2 2 PAN FINE MOVEMENT 16 BIT 0 255 PAN Movement FINE Adjustment 2 3 3 TILT MOVEMENT 8 BIT 0 255 TILT Movement By 270 4 4 TILT MOVEMENT 16 BI...

Страница 37: ...Gobo 10 88 95 Gobo 11 96 103 Gobo 12 104 111 Gobo 13 112 119 Gobo 14 120 126 Gobo 1 Shake From SLOW to FAST 127 133 Gobo 2 Shake From SLOW to FAST 134 140 Gobo 3 Shake From SLOW to FAST 141 147 Gobo 4...

Страница 38: ...ro 13 232 239 Macro 14 240 247 Macro 15 248 255 Macro 16 6 8 10 8 FACET ROTATING PRISM INDEX ROTATION 0 127 Prism Index Rotation 128 189 Clockwise Prism Rotation from FAST to SLOW 190 193 NO Rotation...

Страница 39: ...hange to Any Position 40 59 LAMP ON Value must be maintained for 3 sec 60 79 LAMP Switch OFF Value must be maintained for 3 sec 80 84 ALL Motor Reset Value must be maintained for 3 sec 85 87 SCAN Moto...

Страница 40: ...e error message 01Er 03Er and 05Er flash repeated 5 times If an error does occur during the initial start up procedure the fixture will self generate a second reset signal and try to realign all the m...

Страница 41: ...ear after a fixture reset if the magnetic indexing circuit malfunctions sensor failed or magnet is missing or there is a motor failure defective motor or defective motor IC drive on main PCB This erro...

Страница 42: ...refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following poin...

Страница 43: ...ncluding UV CTO CTB White GOBOS 14 Static Gobos Including 6 Multi Sized Beams CONTROL CONNECTIONS 3 DMX Channel Modes 10 12 16 Pan Movement 540 630 Tilt Movement 270 6 Button Control Panel Full Color...

Страница 44: ...h t i n g c o m 44 RAYZOR BEAM 2R User Manual Ver 1 COLORS GOBOS PHOTOMETRIC DATA Please Note Specifications and improvements in the design of this unit and this manual are subject to change without...

Страница 45: ...w w w e l a t i o n l i g h t i n g c o m 45 RAYZOR BEAM 2R User Manual Ver 1 DIMENSIONAL DRAWINGS...

Страница 46: ...l i g h t i n g c o m 46 RAYZOR BEAM 2R User Manual Ver 1 CIRCUIT SCHEMATICS Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any p...

Страница 47: ...S ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp DRCRAY2R Six Pack Road Case For Rayzor Beam 2R EWDMXSYSTEM Wireless DMX System 1 Transmitter 1 Receiver EWDMXT Wireless DMX Tra...

Страница 48: ......

Отзывы: