background image

 

 

 

 

 

 

 

 

 

 

 

RAYZOR 360Z™ 

user manual

 

 

Содержание RAYZOR 360Z

Страница 1: ...RAYZOR 360Z user manual...

Страница 2: ...f the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142...

Страница 3: ...ted Warranty USA Only 5 Safety Guidelines 6 Maintenance Guidelines 8 Fixture Overview 9 Installation Guidelines 10 System Menu 14 DMX Channel Functions and Values 23 LED Pixel Control 26 Error Codes 2...

Страница 4: ...ustomer support Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Omega Bracket Power Cable CUSTOMER SUPPORT Contact ELATION Service for any product...

Страница 5: ...parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warra...

Страница 6: ...ranty and increase the risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSE...

Страница 7: ...clean and never blocked Allow approx 6 15cm between fixture and other devices or a wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no l...

Страница 8: ...ized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed ele...

Страница 9: ...LCD Menu Function Display 3 MODE ESC Button 4 ENTER Button 5 LEFT Button 6 DOWN Button 7 RIGHT Button 8 UP Button 9 5pin DMX IN 10 5pin DMX OUT 11 RJ45 Ethernet IN 12 RJ45 Ethernet OUT 13 Power Switch...

Страница 10: ...le fixture or multiple fixtures to any metal truss structure or placing the fixture s on any surface a professional equipment installer MUST be consulted to determine if the metal truss structure or s...

Страница 11: ...rn clockwise making sure the fastener is completely locked SAFETY CABLE RIGGING POINT RIGGING Overhead rigging requires extensive experience including amongst others calculating working load limits in...

Страница 12: ...ALL LOCAL NATIONAL AND COUNTRY CODES AND REGULATIONS WHENEVER INSTALLING FIXTURE IN A SUSPENDED ENVIRONMENT POWER LINKING USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER CONSUMPTION...

Страница 13: ...st filters iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific only to ELATION lighting fixtures it is a common issue with lighting fixtures from all manufacturers Al...

Страница 14: ...erent functions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN bu...

Страница 15: ...Close Shutter Auto Program Auto Run If No DMX Pan Reverse ON OFF Pan Reverse Movement Tilt Reverse ON OFF Tilt Reverse Movement Pan Degree 630 540 Pan Degree Select Feedback ON OFF Movement Feedback...

Страница 16: ...rams To Be Run Auto Pro Part2 Program 1 10 Program 2 Auto Pro Part3 Program 1 10 Program 3 Edit Program Program 1 Program Test Testing Program Step 01 SCxxx Program In Loop Program 10 Step 64 SCxxx Sa...

Страница 17: ...n PERSONALITY Service Setting Password 050 NOTE The Service Password MUST be entered in order to access the following menus RDM PID Ethernet IP Ethernet IP Mask and Clear Err Info PERSONALITY Service...

Страница 18: ...each time a reset is performed EFFECT ADJUST Test Channel Auto test each individual channel function independently from the DMX control board EFFECT ADJUST Manual Control Select and manually test and...

Страница 19: ...market for easier operation A total of three user modes may be configured User Mode A User Mode B and User Mode C EDIT PROGRAM Rec Controller The fixture features an integrated DMX recorder by which...

Страница 20: ...ction Mode Press ENTER to confirm Select Auto Program Press ENTER to confirm Select Master or Alone Press ENTER to confirm Press MODE ESC in order to return to the main menu 3 Program Selection for Au...

Страница 21: ...e main menu 5 Automatic Scene Recording Select Edit Program Press ENTER to confirm Select Edit Scenes Select desired scene numbers A maximum of 250 scenes can be programmed Press ENTER to confirm Pres...

Страница 22: ...preset is updated erased or restored to the factory default setting 1 Set ALL DMX channels to zero 0 then set the SPECIAL FUNCTIONS channel CH20 in Basic Mode CH26 in Stand Mode CH32 in Extend Mode t...

Страница 23: ...ILT MOVEMENT 16 BIT 0 255 Fine Control of TILT Movement 3 5 5 PAN CONTINUOUS MOVEMENT 0 127 NO FUNCTION 128 189 PAN Clockwise from FAST to SLOW 190 193 NO Rotation 194 255 PAN Counter Clockwise from S...

Страница 24: ...2 0 255 Green 0 Black 255 100 13 BLUE LED 2 0 255 Blue 0 Black 255 100 14 WHITE LED 2 0 255 White 0 Black 255 100 15 RED LED 3 0 255 Red 0 Black 255 100 16 GREEN LED 3 0 255 Green 0 Black 255 100 17 B...

Страница 25: ...FINE 0 255 Dimmer FINE Adjustment 14 20 25 DIMMER MODES 0 20 Standard 21 40 Stage 41 60 TV 61 80 Architectural 81 100 Theatre 101 255 Default to Setting on Fixture 15 21 26 MOTORIZED ZOOM 0 255 ZOOM...

Страница 26: ...0 79 Color Change Normal 80 84 ALL MOTOR RESET 85 87 SCAN MOTOR RESET 88 90 NO FUNCTION 91 93 EDIT and SAVE WHITE BALANCE ENABLED 94 96 NO FUNCTION 97 99 OTHER MOTORS RESET 100 119 Internal Program 1...

Страница 27: ...or More Errors The fixture cannot function properly with three or more errors therefore the fixture will place itself in a stand by mode until subsequent repairs can be made Less Than 3 Errors The fix...

Страница 28: ...ment 8 16 Bit Resolution Adjustable Pan and Tilt Movement Adjustable Refresh Rate 900 1500 2500 4000 5000 10000 15000 20000 25000 Hz Adjustable Gamma Brightness 2 0 2 2 2 4 2 8 6 Button Touch Panel Fu...

Страница 29: ...io communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television reception which can...

Страница 30: ...30 DIMENSIONAL DRAWINGS Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice...

Страница 31: ...TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp DRCZ360Z 4 Pack Road Case For RAYZOR 360Z AC5PDMX5PRO 5 ft 1 5m 5pin PRO DMX Cable CAT6PRO5 5 ft 1 5m CAT6 EtherCON Cable NEU088 3 ft 1m powerCON...

Страница 32: ......

Отзывы: