I N S T A L L A T I O N G U I D E L I N E S
Vertical Fixture Linking
1. To vertically secure two fixtures, each fixture has integrated locking-pin rails at the top and bottom.
With both fixtures vertically aligned, the bottom rail straddles the top rail of the bottom unit. Note that
the bottom middle rail is stepped and fits into the slot just in back of the middle rail at the top of the
bottom unit.
2. With the locking-pin rail holes aligned, insert a locking-pin at each end (compress the spring of the locking-pin and
rotate the ring 90° to lock it into the rail).
POWER LINKING
USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE
POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX
POWER OUTPUT ON THIS FIXTURE. CHECK SILK SCREEN FOR MAX AMPS.
KLING-NET / ART-NET CONNECTION
When connecting fixture to a network switch to control multiple devices, a
Gigabit
Ethernet Switch
that supports
IGMP (Internet Group Management Protocol)
is required.
Using a
Gigabit Ethernet Switch
that does not support
IGMP
can cause erratic behavior
of all connected devices to the switch. Click link below for more information about IGMP.
https://en.wikipedia.org/wiki/Internet_Group_Management_Protocol