Elation Opti 30 RGB Скачать руководство пользователя страница 3

P

ower Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your Elation Opti 30 

RGB. The Elation Opti 30 RGB is available in a 120v and 220v version. 

Because  line  voltage  may  vary  from  venue  to  venue,  you  should  be 
sure your unit voltages matches the wall outlet voltage before attempt-

ing to operate you fixture.  

DMX-512:

 

DMX is short for Digital Multiplex. This is a universal pro

-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 

and controllers. 

A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav

-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter

-

minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli

-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Opti 30 RGB can be controlled via DMX-512 protocol. The Opti 30 

RGB has 6 DMX Modes. Your unit and your DMX controller require a 
standard  3-pin  XLR  connector  for  data  input  and  data  output  (Figure 

1). If you are making your own cables, be sure to 

use standard two conductor shielded cable (This 
cable may be purchased at almost all pro sound 
and lighting stores). Your cables should be made 
with a male and female XLR connector on either 

end of the cable. Also remember that DMX cable 

must be daisy chained and can not be split.

Elation Professional  -  www.elationlighting.com  - Opti 30 RGB Instruction Manual Page 5

Opti 30 RGB                                                                Set Up

Elation Professional  -  www.elationlighting.com  - Opti 30 RGB Instruction Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

Opti 30 RGB  

                                                      Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con

-

nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 

may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Содержание Opti 30 RGB

Страница 1: ...ligent LED wash This wash is light weight and compact which makes it a great piece for mobile DJ s and clubs This unit can be used as a stand alone or a sound active mode The unit can also be controll...

Страница 2: ...heat registers stoves or other appliances inclu ding amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damag...

Страница 3: ...0 RGB Set Up Elation Professional www elationlighting com Opti 30 RGB Instruction Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the groun...

Страница 4: ...de The display should read 3000 or any variables i e 3001 3002 etc 4 Connect the Slave unit or units and they will automatically start to Opti 30 RGB Operating Instructions Elation Professional www el...

Страница 5: ...ndard DMX controller Select your desired DMX mode and then press the UP or DOWN buttons to adjust the DMX address 3 To run the 1 Channel Mode press the MODE button until 1000 is displayed This is the...

Страница 6: ...will not work when Channel 4 is being used When using Channel 6 Channel 5 will control the speed of the color changing Channel 1 2 and 3 will not work when Channel 4 is being used When using Channel 4...

Страница 7: ...discretion of Elation Professionals All products covered by this warranty were manufactured after January 1 1990 and bear identifying marks to that effect E Elation Professionals reserves the right to...

Страница 8: ...3 Channel Mode 4 Channel Mode 6 Channel Mode 7 Channel Modes Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change with...

Отзывы: