7) etc.
5.3 Call on the Standalone Program
Engage the Send – Mode at the
J
J
O
O
Y
Y
-
-
3
3
0
0
0
0
.
.
The program starts automatically after turning on the unit. In the display you can see
the Next Time for the following step. At the last step the program will jump
automatically to the beginning of the program.
6
Change the Lamp
For a hassle free change of the Light bulb, it is absolutely necessary to follow all
descriptions in this chapter step by step.
6.1 Safety Rules
•
Unplug AC power connection
•
Allow to cool (min. 30 minutes)
•
Don’t touch lamp with bare fingers.
•
Install the lamp with the filler to the right direction.
•
Distance between lamp and lens holder must be min. 5mm.
•
Close the
J
J
O
O
Y
Y
-
-
3
3
0
0
0
0
before you connect the AC power!
6.2 How to change the lamp
Please see Illustration 1 -1.
1. Open the two screws at the top plate.
2. Open the knurled nut and change the HTI/HMD lamp.
3. Close the
J
J
O
O
Y
Y
-
-
3
3
0
0
0
0
in reverse order.
Attention:
Please make sure that the filler of the lamp is in the right direction.
That means not in direction concave mirror or lenses.