Страница 1: ...Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 http www ElationLighting com User Manual 120RZ Software version 1 00 01 DMX manual version 1 0 R R RG G GB B B 1 1 12 2 20 0 0 R R RZ Z Z...

Страница 2: ...Elation Professional Los Angeles CA Error Reference source not found Error Reference source not found 2...

Страница 3: ...Customer Support 4 d Warranty Registration 5 2 Safety Instructions 6 3 Fixture Overview 8 4 Mounting and Installation 12 a Mounting Positions 12 b Securing 14 5 Understanding DMX 15 a DMX Connections...

Страница 4: ...ing shipping If the carton appears to be damaged carefully inspect the unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found...

Страница 5: ...and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be w...

Страница 6: ...ered 3 Attention Don t touch the device during the operation This can cause injuries or damages 4 The fixture doesn t contain any maintainable parts Don t open it 5 It is necessary to wait at least 15...

Страница 7: ...tem will terminate all warranty claims 10 Please keep this instruction manual for later reference 11 Only handle the power cord by the plug Never pull out the plug by tugging the wire portion of the c...

Страница 8: ...3 FIXTURE OVERVIEW 1 Moving head actively and passively cooled 2 Arm with various cooling vents 3 LCD Display Menu data entry 4 Base with various connectors and Camlock mounting system 5 Power On Off...

Страница 9: ...rmined internal operating temperature the fan functions at high speeds The higher speeds provide better cooling associated with higher operating temperatures during long use When the fixture is operat...

Страница 10: ...operation Never defeat this fuse this fuse is designed to protect the electronics in the event of severer power fluctuations In the event of fuse failure always be sure to replace this fuse with an e...

Страница 11: ...on etc Pay attention to the regulations of BGV C1 former VBG 70 and DIN VDE 0711 217 Only qualified staff shall perform the installation For the various mounting positions of the Impression 120RZ stan...

Страница 12: ...led Camlock quick release connectors Turn the two fasteners both 90 to lock them Do the opposite to release them again On both sides you ll find eyelets to pull though a fixing strap This allows an ad...

Страница 13: ...y two Camlock quick release connectors Two half couplers clamps are now used to mount the system to a standard truss bar This technique is necessary to cope with the excessive torque levels that fixtu...

Страница 14: ...a safe and proper fastening Install a safety wire that can hold at least 10 times the weight of the fixture Never use the carrying handles for this purpose 1 3 Connections 1 3 1 Power Supply 100 240 V...

Страница 15: ...The order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in the DMX chain at the begi...

Страница 16: ...tput of your controller and the other side to the male 3 pin XLR input of the fixture Please refer to the diagram below You can chain multiple fixtures together through serial linking The cable needed...

Страница 17: ...ented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The following ch...

Страница 18: ...case of the Impression 120RZ which is up to a 15 channel fixture you should set the starting DMX address of the first unit to 1 the second unit to 16 15 1 the third unit to 31 15 16 and so on Note Dur...

Страница 19: ...ry You may exit the main menu at any time without making any adjustments by tapping the MODE button MODE Button To access the main menu locate the MODE button on the front of the unit Press this butto...

Страница 20: ...r Wheel Manual control for the color wheel Zoom Manual control for zoom Tilt Manual control for Tilt Y movement Display Contrast Adjustment for the Display contrast Default Set Resetting all functions...

Страница 21: ...sently received DMX signal per DMX channel Pan Instantaneous value for Pan Speed Movements Speed adjustment for Pan Tilt movements see item below Pan Tilt Movements Instantaneous value for Pan Tilt mo...

Страница 22: ...ce not found 22 High Resolution Fixture works in High Resolution mode see also section 0 below White Mode ON OFF Adjustments for white balance are activated Reverse Pan ON OFF Invert Pan movements Rev...

Страница 23: ...46 5 White CTB Color temperature 7200K 120 127 78 7F 47 49 5 Rainbow Effect Stop 2 128 80 50 Rainbow Effect 3 slow fast 129 223 81 DF 51 88 Rainbow Effect random colors slow fast 224 255 E FF 89 100 6...

Страница 24: ...ed of the movements channel 13 Pan Min 660 200s Pan Max 660 3 2s Tilt Min 300 110s Tilt Max 300 1 5s 16 255 10 FF 7 100 15 Zoom Spot Flood 10 26 0 255 00 FF 0 100 4 Max Power Mode vs White Mode The Im...

Страница 25: ...38 40 5 White CTO Color temperature 3200K 104 111 68 6F 41 43 5 White Color temperature 5600K 112 119 70 77 44 46 5 White CTB Color temperature 7200K 120 127 78 7F 47 49 5 Rainbow Effect Stop 2 128 80...

Страница 26: ...Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 249...

Страница 27: ...1 Normal Mode b 600Hz Mode Hold down the DOWN button during power ON After switching ON the system the LEDs will be operated with a Pulse Width Modulation PWM of 600Hz In addition all standard setting...

Страница 28: ...fixture to operate reliably throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recom mended under no circumstances should alcohol or solvents be used 1 5 Safet...

Страница 29: ...blue LEDs 42x red LEDs Wavelength optimized for maximum presentable color space Optical System High efficient Collimator cluster Fixed optical mount with an angel of reflected beam between 10 26 Shutt...

Страница 30: ...nstruction Version 1 Internet 2 L LED Class 2M 6 M Maintenance 18 Max Power Mode 15 Menu Field 11 Micro fuse 10 Mode key 11 Mounting 7 Mounting in hanging Position 8 Mounting in sidewise Position 9 Mo...

Страница 31: ...Elation Professional Los Angeles CA Error Reference source not found Error Reference source not found 31 NOTES...

Страница 32: ...Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 323 582 3322 Voice 323 832 9142 Fax www ElationLighting com...