Error Codes subject to change without notice
ERROR CODES
DESCRIPTION
PAN Er
Movement is not located in the default position after the reset.
These messages will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed, or magnet is missing) or there is
a motor failure (defective motor or a defective motor IC drive on the
main PCB). This error may also be displayed if the head/yoke was blocked
during a reset function.
TILT Er
RotGobo
Movement is not located in the default position after the reset. These
messages will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed, or magnet is missing) or there is a
motor failure (defective motor or a defective motor IC drive on the main
PCB).
RotGobo2
Iris
RotGoboIndex
RotGobo2Index
Animation
Anima.Index
Zoom
Focus
Frost
Prism
PrismIndex
HeadTemp
These messages will appear if there is a temperature and/or fan
malfunction.
CoolFan1
CoolFan2
CoolFan3
CoolFan4
BaseTemp
BaseFan