30
E R R O R C O D E S
Error Codes subject to change without notice.
ERROR CODES
DESCRIPTION
PAN Er
Movement is not located in the default position after the reset.
These messages will appear after a fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed, or magnet is missing)
or there is a motor failure (defective motor or a defective motor IC
drive on the main PCB). This error may also be displayed if the
head/yoke was blocked during a reset function.
TILT Er
RotGobo
Movement is not located in the default position after the reset.
These messages will appear after a fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed, or magnet is missing)
or there is a motor failure (defective motor or a defective motor IC
drive on the main PCB).
GoboIndex
Iris
Blade
Zoom
Focus
Frost
HeadTemp
These messages will appear if there is a temperature and/or fan
malfunction.
CoolFan1
CoolFan2
CoolFan3
CoolFan4
BaseTemp
BaseFan