Elation Focus Spot 250R Скачать руководство пользователя страница 33

Focus Spot 250R™

©Elation Professional®                                             

33                                                   

Focus Spot 250R™

number  of  steps  under  Step  (S-01-  S-48).  You  can  edit  the  individual  scenes  under

Edit.

1.

Access the main menu.

2.

Tap the UP button until 

EDIT

 is displayed, press ENTER.

3.

Tap the UP button until 

RUN

 is displayed, press ENTER.

4.  “AUTO

is  displayed.  If  you  press  the  UP  button  it  will  show 

S O U N

.

Select which one you want to activate, and press ENTER.

5.  Press  UP,  to  select 

ALON

  or 

NAST

.  Which  mean  stand  alone,  and

master/slave mode.

6.  Select a mode, and press ENTER to confirm.

7.  Press MODE/ESC to return to the main menu.

 

STEP

 - With this function you can program the number of

  steps in your

individual Program.

1.

Access the main menu.

2.  Tap the UP button until 

EDIT

 is displayed, press ENTER.

3.  Tap the UP button until 

STEP

 is displayed, press ENTER.

4.  The display shows “S-01,” this indicates the first step of your program. You can

call up to 48 scenes in “Run.” For example; if “S-05” is displayed, it means that

the scene will “RUN” the first 5 scenes you saved in “Edit.”

5.  Press ENTER to save and MODE/ESC to exit.

 

SC01

 - This function allows you to choose the total number of scenes in your

internal program.

1.  Access the main menu.

2.  Tap the UP button until “EDIT” is displayed, press ENTER.

3.  Tap the UP button until “SC01” is displayed.

4.  The display indicates “SC01,” this stands for the first scene of your program.

You may recall up to 48 scenes. For example, if  you choose “SC05,”  and then

select the “Run” function, the first 5 scenes you saved in “Edit” mode will run.

5.  Press ENTER to save and MODE/ESC to exit.

Editing procedure 1

: Using the control board only.

1.

 

Access the main menu.

Содержание Focus Spot 250R

Страница 1: ...Rev 10 28 05 FOCUS SPOT 250R Elation Professional 4295 Charter Street Los Angeles Ca 90058 www elationlighting com...

Страница 2: ...Focus Spot 250R Elation Professional 2 Focus Spot 250R...

Страница 3: ...Lamp optimization 11 6 Mounting and Installation 12 a Mounting Positions 12 b Mounting Points 12 c Securing 13 7 Understanding DMX 15 a DMX Connections 15 b DMX Terminator 15 c 3 Pin to 5 Pin Conversi...

Страница 4: ...nit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dealer without...

Страница 5: ...roperly handled Never touch the lamp with your bare hands as the oil from your hands will shorten lamp life Also never move the fixture until the lamps have had ample time to cool Remember lamps are n...

Страница 6: ...ice falls under protection class I Therefore it is essential that the device be grounded properly All electrical connections must carried out by qualified person Be sure the available voltage matches...

Страница 7: ...the FOCUS SPOT 250R To prevent personal injury never touch the lamp if you are not absolutely sure it has cooled 5 Never look directly into the lamp beam You risk injury to your retina which may induc...

Страница 8: ...ged or frayed Important Notice Damages resulting from the disregard of safety and general user instructions found in this user manual are not subject to any warranty claims Never look directly into th...

Страница 9: ...0 Discharge Lamp Lamp switches ON OFF locally Glass Dichroic Reflector for Even Lamp Output User Selectable Power Supply Internal USITT DMX 512 Complaint RDMX Remote DMX addressing from any DMX consol...

Страница 10: ...t The minimum distance between the fixture and a wall or flat surface should be at least 5 meter Always install the fixture with an appropriate safety cable When installing the fixture in a suspended...

Страница 11: ...a cloth to handle the lamps during insertion and removal Do not install lamps with a higher wattage They generate higher temperatures than which the device was designed for For the installation you ne...

Страница 12: ...ike the lamp and focus the light on a flat surface beam open white no gobo no effects 2 Center the hot spot the brightest part of the beam using the 3 adjustment screws Turn one screw at a time to dra...

Страница 13: ...plied safety cable as a safety measure to prevent accidental damage in the event of a clamp failure see section b on the next page Refer to regulations BGV C1 formerly VBG 70 and DIN VDE0711 217 for p...

Страница 14: ...lock attach the cam lock to the designated position on the bottom of your unit Lock the cam lock into position by turning the wing nuts 90 90 b Be sure to always use two cam locks mounted to the bott...

Страница 15: ...s Do not use the ground lug on the XLR connector Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding th...

Страница 16: ...XLR connector of the last fixture in your daisy chain to terminate the line Using a cable terminator Elation part number Z DMX T will decrease the possibilities of erratic behavior CONTROLLER 5 Pin X...

Страница 17: ...to the same DMX address will subsequently control all fixtures in the same fashion in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixtu...

Страница 18: ...fixture is connected to a DMX controller and the display is flashing not receiving a DMX signal please check the following The 3 PIN XLR plug cable with DMX signal from controller is not connected or...

Страница 19: ...g has been made and locked into memory You may exit the main menu at any time without making any adjustments by tapping the EXIT button MODE ESC Button To access the main menu locate the MODE ESC butt...

Страница 20: ...8 bit 10 DEGR 630 540 Pan degree select 11 MIC M XX M 70 Mic sensitivity VALU D XX D 00 DXXX Display the DMX512 value of each channel D ON ON OFF Display turn off after 2mins 12 DISP FLIP ON OFF This...

Страница 21: ...s the current three digit address will immediately begin to flash 3 While the current three digit address is flashing use theUp and Down buttons to select adjust the address Lock your new address into...

Страница 22: ...internal scenes 1 Access the main menu 2 Tap the UP button until PLAY is displayed press ENTER 3 Tap the UP button until RUN is displayed press ENTER 4 Tap the UP button to select either Master or Al...

Страница 23: ...menu 5 RESE RESET MENU ALL Resets all the motors in the unit SCAN Resets the Pan and Tilt motors COLR Color Resets the color motors GOBO Resets the gobo motors SHTR Resets the shutter motors OTHR Res...

Страница 24: ...ess MODE ENTER 5 Press MODE ESC to return to the main menu SHTR When you activate this reset function the fixture will only reset the shutter dimmer motor 1 Access the main menu 2 Tap the UP button un...

Страница 25: ...g time of the lamp 1 Access the main menu 2 Tap the UP button until TIME is displayed press ENTER 3 Tap the UP button until LAMP is displayed press ENTER 4 Press MODE ESC to return to the main menu CL...

Страница 26: ...s menu function will reverse the mirror TILT movements 1 Access the main menu 2 Tap the UP button until RTLT is displayed press ENTER 3 The display will show ON OFF 4 Press the UP button to select ON...

Страница 27: ...unction is turned on the fixture will operate with a pan movement of 630 DEGR This menu function will toggle between the 630 and 540 for pan movement 1 Access the main menu 2 Tap the UP button until D...

Страница 28: ...be displayed 5 Press ENTER to confirm 6 Press MODE ESC to return to the main menu D ON This function will turn the display off after the unit has gone two seconds without any activity 1 Access the ma...

Страница 29: ...r OFF VER Version Displays the software version SPEC MAIN MENU LAAU This function control the automatic lamp start feature By default the unit will automatically ignite the lamp when unit is turned on...

Страница 30: ...et the starting address to 57 set channel 1 to a value of 7 set channel 2 to a value of 7 and use channel 3 to set your address to 57 by selecting a channel value of 57 Example 2 If you want to set th...

Страница 31: ...this function or OFF to deactivate this function 6 Press ENTER to confirm 7 Press MODE ESC to return to the main menu DFSE With this function you can restore the factory settings of the device All se...

Страница 32: ...5 Press ENTER or MODE ESC to exit EDIT This menu item allows you to write a program into the memory EEPROM via the control panel or via the external controller 13 EDIT MENU This menu item allows you t...

Страница 33: ...EDIT is displayed press ENTER 3 Tap the UP button until STEP is displayed press ENTER 4 The display shows S 01 this indicates the first step of your program You can call up to 48 scenes in Run For ex...

Страница 34: ...steps 5 8 until you finish setting all the DMX values for all the channels of this scene each scene can have 15 channels maximum 9 Once all the channels are completed the display will begin to flash...

Страница 35: ...play shows OFF 7 Press UP the display shows ON 8 Press MODE ESC the display shows SC02 You successfully downloaded the first scene 9 Adjust the Step time as described above 10 Call up the second scene...

Страница 36: ...an movement pan fine CHANNEL 3 Tilt movement max 265 CHANNEL 4 16 bit tilt movement tilt fine CHANNEL 5 Select one of the 9 colors color cycle or rainbow effect CHANNEL 6 Select one of the 6 gobo s op...

Страница 37: ...ation 194 255 Counter Clockwise Color Scroll slow to fast Channel 6 Gobo 0 9 Open 10 19 Gobo 1 20 29 Gobo 2 30 39 Gobo 3 40 49 Gobo 4 50 59 Gobo 5 60 69 Gobo 6 70 89 Gobo 1 Shake slow to fast 90 109 G...

Страница 38: ...5 Blackout by movement 236 245 Blackout by all wheel changing 246 255 No function Channel 11 Special Functions 0 19 Color change normal No split colors 20 39 Split Color Operation 40 59 Lamp on 60 79...

Страница 39: ...en corrected the fixture will make the following determinations 1 3 or more errors The fixture cannot function properly with three or more errors therefore the fixture will place itself in a stand by...

Страница 40: ...ted in the default position after start up or after a reset command This message will appear after a fixture reset if the gobo wheel s magnetic indexing circuit malfunctions sensor failed or magnet is...

Страница 41: ...th unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage have to be adhered by a skille...

Страница 42: ...ct Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered...

Страница 43: ...of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall ap...

Страница 44: ...ement 630 in 3 5 sec default 540 user selectable Tilt Movement 265 in 2 0 sec Focus Motor driven focus from near to far DMX Drive Standard DMX 512 3 pole XLR Pin 3 Pin 2 Ground Pin 1 Colors 8 Dichroic...

Страница 45: ...Focus Spot 250R Elation Professional 45 Focus Spot 250R Photometric Data Gobos Dimensional Drawings...

Страница 46: ...Focus Spot 250R Elation Professional 46 Focus Spot 250R...

Страница 47: ...Focus Spot 250R Elation Professional 47 Focus Spot 250R...

Страница 48: ...Focus Spot 250R Elation Professional 48 Focus Spot 250R Elation Professional 4295 Charter Street Los Angeles CA 90058 323 582 3322 323 582 3108 fax www ElationLighting com info ElationLighitng com...

Отзывы: