 EPAR QW                                                       Specifications

  Model:  EPAR QW

   SPECIFICATIONS:

 

   Working Position:   

Any safe working position

   Voltage:    

 

100V ~ 240V/47~63Hz

   LED’s: 

 

 

14 x 1 Watt Quad LED’s (14 Red, 

   

 

 

 

14 Blue, 14 Green, & 14 White)

  Power Consumption: 

78.4W 

 

Fuse:   2.5 

Amp

  Beam Angle: 

 

10 Degrees

  Weight:     

 

9lbs./ 4.1Kgs.

   Dimensions:  

 

9.9” (L) x 8.5” (W) x 11” (H)

   Colors: 

 

 

RGBW Color Mixing

   DMX Channels:   

6 DMX Modes: 1 Channel Mode,   

   

 

 

 

2 Channel Mode, 4 Channel Mode,  

   

 

 

 

5 Channel Mode, 7 Channel Mode,  

   

 

 

 

& 8 Channel Mode

  Warranty:                         2 Year (730 days)

Please Note: Specifications and improvements in the design of 

this unit and this manual are subject to change without any prior 

written notice.

Auto Sensing Voltage: This fixture contains a automatic voltage 

switch, which will auto sense the voltage when it is plugged into 

the power source.

©Elation Professionals® 

A Division of the AmericanDJ® Group of Companies

World Headquarters:

6122 S. Eastern Ave. Los Angeles, CA 90040 USA

Tel: 323-582-3322 Fax: 323-832-9142

Web: www.elationlighting.com  E-mail: [email protected]

American DJ Europe

Junostraat 2

6468 EW Kerkrade

Netherlands

[email protected] / www.americandj.eu

Tel: +31 45 546 85 00 / Fax: +31 45 546 85 99

Elation Professional  -  www.elationlighting.com  - EPAR QW Instruction Manual Page 19

Содержание Epar QW

Страница 1: ...ful DMX intelligent 4 in 1 RGBW Red Green Blue White LED wash This wash is light weight and compact which makes it a great piece for mobile DJ s and clubs This unit can be used as a stand alone or a sound active mode The unit can also be con trolled via DMX controller Customer Support Elation provides a customer support line to provide set up help and to answer any question should you encounter pr...

Страница 2: ...ing amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in performance EPAR QW Warranty Registration EPAR...

Страница 3: ... sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split Elation Professional www elationlighting com EPAR QW Instruction Manual Page 5 EPAR QW Set Up Elation Profes...

Страница 4: ...m EPAR QW Instruction Manual Page 7 RGB Mode 1 Plug the fixture in and press the MODE button until 2 When rXXX is displayed you are in Red dimming mode Press the UP and DOWN buttons to adjust intensity 3 When GXXX is displayed you are in Green dimming mode Press the UP and DOWN buttons to adjust intensity 4 When bXXX is displayed you are in Blue dimming mode Press the UP and DOWN buttons to adjust...

Страница 5: ...ur desired mode or operation 3 For the Slave unit s set the display to any DMX channel mode Example Set the unit to 4 channel mode the display should read 3000 or any variables i e 3001 3002 etc 4 Connect the Slave unit or units and they will automatically start to follow the Master EPAR QW Master Slave Configuration Channel Value Function 1 COLOR MACROS 0 OFF 1 4 MACRO 1 5 8 MACRO 2 9 12 MACRO 3 ...

Страница 6: ...hannel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 WHITE 0 255 0 100 EPAR QW 1 Channel Mode DMX Values and Functions Channel Value Function 1 COLOR MACROS CONT 129 132 MACRO 33 133 136 MACRO 34 137 140 MACRO 35 141 144 MACRO 36 145 148 MACRO 37 149 152 MACRO 38 153 156 MACRO 39 157 160 MACRO 40 161 164 MACRO 41 165 168 MACRO 42 169 172 MACRO 43 173 176 MACRO 44 177 18...

Страница 7: ...ofessional www elationlighting com EPAR QW Instruction Manual Page 14 Channel 1 2 3 4 will not work when Channel 5 is being used When using Channel 7 Channel 6 will control the speed of the color changing EPAR QW 8 Channel Mode DMX Values and Functions Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 WHITE 0 255 0 100 5 1 255 COLOR MACROS PLEASE SEE 1 CHANNEL MODE ...

Страница 8: ...cro 37 254 121 0 0 macro 6 223 255 83 83 macro 38 176 17 0 0 macro 7 255 243 77 77 macro 39 96 0 11 0 macro 8 255 200 74 74 macro 40 234 139 171 0 macro 9 255 166 77 77 macro 41 224 5 97 0 macro 10 255 125 74 74 macro 42 175 77 173 0 macro 11 255 97 77 74 macro 43 119 130 199 0 macro 12 255 71 77 71 macro 44 147 164 212 0 macro 13 255 83 134 83 macro 45 88 2 163 0 macro 14 255 93 182 93 macro 46 0...

Страница 9: ...e manufactured after January 1 1990 and bear identifying marks to that effect E Elation Professionals reserves the right to make changes in design and or improvements upon its products without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described abo...

Страница 10: ...vements in the design of this unit and this manual are subject to change without any prior written notice Auto Sensing Voltage This fixture contains a automatic voltage switch which will auto sense the voltage when it is plugged into the power source Elation Professionals A Division of the AmericanDJ Group of Companies World Headquarters 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 3322...

Отзывы: