Elation ELED STRIP 100 Скачать руководство пользователя страница 3

P

ower Supply:

 Before plugging your unit in, be sure the source voltage 

in your area matches the required voltage for your Elation ELED Strip 
100. The Elation ELED Strip 100 is available in a 120v and 220v version. 
Because  line  voltage  may  vary  from  venue  to  venue,  you  should  be 
sure your unit voltages matches the wall outlet voltage before attempt-

ing to operate you fixture.  

DMX-512:

 

DMX is short for Digital Multiplex. This is a universal pro

-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav

-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter

-

minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli

-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The ELED Strip 100 can be controlled via DMX-512 protocol. The ELED 
Strip 100 has 6 DMX modes, please see pages 10-12 for the different 
modes. The DMX address is set on the back panel of the ELED Strip 
100.  Your  unit  and  your  DMX  controller  require  a  standard  3-pin  XLR 
connector for data input and data output (Figure 
1). If you are making your own cables, be sure to 
use standard two conductor shielded cable (This 
cable may be purchased at almost all pro sound 
and lighting stores). Your cables should be made 
with a male and female XLR connector on either 
end of the cable. Also remember that DMX cable 
must be daisy chained and can not be split.

©

Elation Lighting

®

  -  www.elationlighting.com  - ELED Strip 100 Instruction Manual Page 5

  ELED Strip 100                                                    Set Up

©

Elation Lighting

®

  -  www.elationlighting.com  - ELED Strip 100 Instruction Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

 ELED Strip 100   

                                  Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 

may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Содержание ELED STRIP 100

Страница 1: ...LED color bar This effect can be used in a stand alone mode or connected in a Master Slave configuration The unit can also be controlled via DMX controller This wash has four operating modes Sound Act...

Страница 2: ...nst them paying particular attention to the point they exit from the unit Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 15 for cleaning details Heat The appli...

Страница 3: ...hting com ELED Strip 100 Instruction Manual Page 5 ELED Strip 100 Set Up Elation Lighting www elationlighting com ELED Strip 100 Instruction Manual Page 6 Figure 1 Notice Be sure to follow figures two...

Страница 4: ...put The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only You can also daisy chain the power cords this can only be...

Страница 5: ...DOWN buttons to adjust the DMX address 3 To run the 3 Channel Mode press the MODE button until XXX1 is displayed This is the DMX addressing for the 3 Channel Mode 4 To run the 5 Channel Mode press th...

Страница 6: ...Red Green Blue 7 8 and Red Green Blue 9 10 refer to sections of the ELED Strip 100 Please see the refer to the diagram on this page 1 2 3 4 6 7 8 9 10 5 ELED Strip 100 Diagram Channel Value Function...

Страница 7: ...5 BLUE 1 0 100 4 0 255 RED 2 0 100 5 0 255 GREEN 2 0 100 6 0 255 BLUE 2 0 100 7 0 255 RED 3 0 100 8 0 255 GREEN 3 0 100 9 0 255 BLUE 3 0 100 10 0 255 RED 4 0 100 11 0 255 GREEN 4 0 100 12 0 255 BLUE 4...

Страница 8: ...d bear identifying marks to that effect E Elation Professionals reserves the right to make changes in design and or improvements upon its products without any obligation to include these changes in an...

Страница 9: ...l Mode 5 Channel Mode Two 6 Channel Modes 15 Channel Mode 30 Channel Mode Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to...

Отзывы: