 ELED QA Strip                                      Safety Precautions

Elation Professional  -  www.elationlighting.com  - ELED QA Strip Instruction Manual Page 4

Elation Professional  -  www.elationlighting.com  - ELED QA Strip Instruction Manual Page 3

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 19 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

 ELED QA Strip 

  

                   Warranty Registration

 ELED QA Strip    

 

                              Features

To optimize the performance of this product, please read these 

operating instructions carefully to familiarize yourself with the basic 

operations of this unit. These instructions contain important safety 

information regarding the use and maintenance of this unit. Please 

keep this manual with the unit, for future reference.

 ELED QA Strip    

                     General Instructions

•  Multi-Colors

•   Built in Microphone

•   Four Operating Modes

•  68 Color Macros

•   DMX-512 protocol

•   9 DMX Modes: 1 Channel Mode, 2 Channel Mode, 4 Channel    

  Mode, 5 Channel Mode, 7 Channel Mode, 8 Channel Mode, 36  

  Channel Mode, 54 Channel Mode, & 72 Channel Mode.

•  Pixel Direction Control: The direction in which the pixels light up  

  can be reversed so that the pixels can light up at either end of the  

  bar. This feature is used with 36 DMX Channel mode, 54 DMX   

  Channel mode, and 72 DMX Channel mode. This feature is also  

  used with some built-in programs under Program Mode.

The ELED QA Strip carries a two year limited warranty. Please fill out 

the enclosed warranty card to validate your purchase. All returned 

service items whether under warranty or not, must be freight pre-paid 

and accompany a return authorization (R.A.) number. The R.A. number 

must be clearly written on the outside of the return package. A brief 

description of the problem as well as the R.A. number must also be 

written down on a piece of paper included in the shipping carton. If 

the unit is under warranty, you must provide a copy of your proof of 

purchase invoice. You may obtain a R.A. number by contacting our 

customer support team on our customer support number. All pack-

ages returned to the service department not displaying a R.A. number 

on the outside of the package will be returned to the shipper.

Содержание ELED QA Strip

Страница 1: ...ELED QA Strip is a powerful DMX intelligent 4 in 1 RGBA Red Green Blue Amber LED strip This unit can has 4 operat ing modes Macro mode Program mode RGBA mode and DMX con trolled This unit can be used...

Страница 2: ...cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate norm...

Страница 3: ...use stan dard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end...

Страница 4: ...tion Professional www elationlighting com ELED QA Strip Instruction Manual Page 7 speed by following the next set of instructions The direction of cer tain programs can also be changed under Direction...

Страница 5: ...the Elation Show Designer or the Elation DMX Operator 2 To run your fixture in DMX mode plug in the fixture via the XLR con nections to any standard DMX controller Select your desired DMX mode and the...

Страница 6: ...0 3 BLUE 0 255 0 100 4 AMBER 0 255 0 100 5 0 255 COLOR MACROS PLEASE SEE COLOR MACRO CHART ON PAGE 17 6 0 15 NOTHING 16 255 STROBING SPEED CONTROL 7 MASTER DIMMER 0 255 0 100 Channel 1 2 3 4 will not...

Страница 7: ...7 MODE 0 127 OFF 128 159 AUTO MIX 160 191 3 COLOR JUMP 192 223 7 COLOR JUMP 224 255 SOUND ACTIVE 8 MASTER DIMMER 0 255 0 100 ELED QA Strip 36 Channel Mode Channel Value Function 1 RED LED 1 2 0 255 0...

Страница 8: ...EN LED 17 0 255 0 100 67 BLUE LED 17 0 255 0 100 68 AMBER LED 17 0 255 0 100 69 RED LED 18 0 255 0 100 70 GREEN LED 18 0 255 0 100 71 BLUE LED 18 0 255 0 100 72 AMBER LED 18 0 255 0 100 ELED QA Strip...

Страница 9: ...55 71 77 71 Macro mode44 173 176 147 164 212 0 Macro mode13 49 52 255 83 134 83 Macro mode45 177 180 88 2 163 0 Macro mode14 53 56 255 93 182 93 Macro mode46 181 184 0 38 86 0 Macro mode15 57 60 255 9...

Страница 10: ...ts without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with prod...

Страница 11: ...n Professional www elationlighting com ELED QA Strip Instruction Manual Page 21 Elation Professional www elationlighting com ELED QA Strip Instruction Manual Page 22 ELED QA Strip Notes ELED QA Strip...

Страница 12: ...e 72 Channel Mode Warranty 2 Year 730 days Elation Professionals 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 3322 Fax 323 832 9142 Web www elationlighting com E mail info elationlighting c...

Отзывы: