ELAR TRI PAR IP         2 Channel - DMX Values & Functions

  Channel   Value  

                 Function

       

1             1 - 255                     COLOR MACROS

                                           PLEASE SEE CHANNEL 1 MODE                 
       2                                            MASTER DIMMER
                      1 - 255                          0% - 100%

ELAR TRI PAR IP         3 Channel - DMX Values & Functions

  Channel   Value  

                 Function

       

1                                                       RED

                      1 - 255                          0% - 100%           
       2                                                     GREEN

        

                                                                               

                 
                      1 - 255                          0% - 100%
       3                                                       BLUE
                      1 - 255                          0% - 100%

ELAR TRI PAR IP         4 Channel - DMX Values & Functions

  Channel   Value  

                 Function

       

1                                                       RED

                      1 - 255                          0% - 100%           
       2                                                     GREEN

        

                                                                               

                 
                      1 - 255                          0% - 100%
       3                                                       BLUE
                      1 - 255                          0% - 100% 
       4                                            MASTER DIMMER
                      1 - 255                          0% - 100%    

ELAR TRI PAR IP         6 Channel - DMX Values & Functions

  Channel   Value  

                 Function

       

1                                                       RED

                      1 - 255                          0% - 100%           
       2                                                     GREEN

        

                                                                               

                 
                      1 - 255                          0% - 100%
       3                                                       BLUE
                      1 - 255                          0% - 100% 
       4             1 - 255                    COLOR MACROS
                                           PLEASE SEE CHANNEL 1 MODE
       5                                                   STROBING
                      0 - 15                                  OFF
                    16 - 255                         SLOW - FAST 
       6                                            MASTER DIMMER
                      1 - 255                          0% - 100%

Содержание ELAR TRI PAR IP

Страница 1: ...X intelligent RGB LED wash This wash is light weight and compact which makes it a great piece for mobile DJ s and clubs This unit can be used as a stand alone or a sound active mode The unit can also be controlled via DMX con troller Customer Support Elation provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initia...

Страница 2: ...gisters stoves or other appliances inclu ding amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in perf...

Страница 3: ...sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split Elation Architectural www elationlighting com ELAR TRI PAR IP Instruction Manual Page 5 ELAR TRI PAR IP Set U...

Страница 4: ...play should read 3000 or any variables i e 3001 3002 etc 4 Connect the Slave unit or units and they will automatically start to ELAR TRI PAR IP Operating Instructions Elation Architectural www elationlighting com ELAR TRI PAR IP Instruction Manual Page 8 Elation Architectural www elationlighting com ELAR TRI PAR IP Instruction Manual Page 7 follow the Master Sound Active Mode In this mode the ELAR...

Страница 5: ...r DMX values and traits Channel Value Function 1 COLOR MACROS 0 OFF 1 7 BASTARD AMBER 8 15 MEDIUM AMBER 16 23 PALE AMBER GOLD 24 31 GALLO GOLD 32 39 GOLDEN AMBER 40 47 LIGHT RED 48 55 MEDIUM RED 56 63 MEDIUM PINK 64 71 BROADWAY PINK 72 79 FOLLIES PINK 80 87 LIGHT LAVENDER 88 95 SPECIAL LAVENDER 96 103 LAVENDER 104 111 INDIGO 112 119 HEMSLEY BLUE 120 127 TIPTON BLUE 128 135 LIGHT STEEL BLUE 136 143...

Страница 6: ...0 ELAR TRI PAR IP 3 Channel DMX Values Functions Channel Value Function 1 RED 1 255 0 100 2 GREEN 1 255 0 100 3 BLUE 1 255 0 100 ELAR TRI PAR IP 4 Channel DMX Values Functions Channel Value Function 1 RED 1 255 0 100 2 GREEN 1 255 0 100 3 BLUE 1 255 0 100 4 MASTER DIMMER 1 255 0 100 ELAR TRI PAR IP 6 Channel DMX Values Functions Channel Value Function 1 RED 1 255 0 100 2 GREEN 1 255 0 100 3 BLUE 1...

Страница 7: ...ems the user may encounter with solutions Unit not responding to DMX 1 Check that the DMX cables are connected properly and are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and outputs are connected Unit does not respond to sound 1 Quiet or high pitched sounds will not ac...

Страница 8: ...fects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professionals factory unless prior written authorization was issued to purchaser by Elation Profes sionals if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include mainte nance ...

Отзывы: