Elation ELAR Tri Brick Скачать руководство пользователя страница 24

 
 

ELAR Tri Brick

 

©Elation Professional, Los Angeles Ca. 

23 

 

www.ElationLighting.com

   

<DFSE> - Restore Default   

This function is used to restore the factory settings of the device. All settings will be set 

 

back to the default values (shaded). Any edited scenes will be lost. 

 

<VER> Software Version 

This function will display the current firmware version. 

 

9.3 “MANL” – Manual Fixture Settings: 

This function allows the each of the nine DMX channels to be controlled manually. This 

will allow the fixture to be preset to a specific color or built-in program without the use of 

a DMX console. 

 

9.4 “TIME” – Operating Hours

 

These functions will detail different time functions associated with the fixture.   

   

<LIFE> (0000~9999 Hours) 

This function tracks the running time of the fixture from the point it was last cleared. 

Where “XXXX ”represents the total number of running hours. This time is none 

destructive and will remain in the fixtures memory indefinitely. Use this time to track 

rentals or show durations. 

 

<CODE> Clear run time access code 

This lock-out code prevents the current run time from being erased accidently. The 

access code is “038” 

 

<CLFE> Clear Fixture Run Time 

This function resets the run time to zero.   

 

9.5 “Edit” Internal Program Settings: 

 

The fixture comes equipped with a built-in DMX recorder that allows custom programs to 

 

be installed and recalled directly from the fixture’s control board. Programs can be 

 

created and stored using the fixture’s control board or by using an external DMX 

Содержание ELAR Tri Brick

Страница 1: ...Rev 2 26 2010 visage Version 1 0 ELAR Tri Brick Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 www elationlighting com...

Страница 2: ...ELAR Tri Brick Elation Professional Los Angeles Ca 1 www ElationLighting com...

Страница 3: ...9 6 Mounting and Installation 12 7 Understanding DMX 15 a DMX Cables 15 b DMX Terminator 16 c 3 Pin to 5 Pin Conversion 17 d Fixture DMX Addressing 16 8 Display Indicators 19 9 Display Menu 20 10 DMX...

Страница 4: ...y to operate the fixture have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Inside the box you should find th...

Страница 5: ...nder warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the pro...

Страница 6: ...pter six of this manual Operating the ELAR TRI BRICK without suited safety aids such as safety cables or clamps can increase the risk of damage and or personal injury 5 Qualified and certified personn...

Страница 7: ...ocedure 13 Only handle the power cord by the plug Never pull out the plug by tugging the wire portion of the cord 14 Please be aware that damages caused by modifications to the device are not subject...

Страница 8: ...cros Strobe effect with a maximum flash rate of 18fps DMX controlled operation or stand alone operation with Master Slave function 7 built in programs can be called up via DMX controller 48 preprogram...

Страница 9: ...treme heat moisture or dust The minimum distance between the fixture and a wall or flat surface should be at least 0 5 meter about 1 5ft See page 12 Always install the fixture with an appropriately ra...

Страница 10: ...hting com 5 FIXTURE OVERVIEW 1 LED Lens Assembly The lens assembly may be user replaced in the event repair is needed or a different beam angle is required 2 Locking Knob This knob is used to lock the...

Страница 11: ...ming DMX signal to the next fixture in the DMX chain To maintain the integrity of the IP rating only use proper Elation IP rated DMX cables 7 Main Power Input Lead This lead is the main power input le...

Страница 12: ...onLighting com functions and settings 12 Enter Button The enter button is used to enter in to a certain menu function or to lock a menu setting in to memory 13 LED Display 4 segment menu display Used...

Страница 13: ...g removing or servicing the fixture Refer to regulations BGV C1 formerly VBG 70 and DIN VDE0711 217 for proper installation in Europe To ensure proper installation only qualified staff should attempt...

Страница 14: ...materials decoration etc When clamp mounting always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure See the image belo...

Страница 15: ...r hole of the hanging yoke As an added safety measure be sure to attach at least one properly rated safety cable to the fixture See illustrations below Securing the ELAR TRI BRICK Always be sure to se...

Страница 16: ...DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the middle The DMX c...

Страница 17: ...ure to daisy chain your in and out data connections never split or Y your DMX connections unless you are using an approved DMX splitter such as the Elation Opto Branch 4 or DMX Branch 4 DMX 512 connec...

Страница 18: ...arting DMX address is achieved by setting the correct DMX address on the digital display located on the back of the fixture You can set the same starting address for all fixtures or a group of fixture...

Страница 19: ...XXX XXX representing the actual DMX address If your fixture is connected to a DMX controller and the display is flashing not receiving a DMX signal please check the following The 3 pin or 5 pin XLR p...

Страница 20: ...ndicator on the display This indicator is designed to give a quick visual indication of the fixtures DMX status The illustration below details the functionality of the LED indicators The LED indicator...

Страница 21: ...ng also allows the fixture to ignore any DMX information coming from the controller that is not meant specifically for the fixture Because each fixture is connected VALU A001 AXXX AXXX DMX address set...

Страница 22: ...e for operation in Master Slave mode Each slave setting will have a different function for a dynamic lightshow without a controller RDMX Address via DMX This function allows the DMX address to remotel...

Страница 23: ...l operation to avoid excessive light in situations that require an extremely dark environment This function will adjust the time delay the fixture will remain on before it turns off This function is d...

Страница 24: ...me functions associated with the fixture LIFE 0000 9999 Hours This function tracks the running time of the fixture from the point it was last cleared Where XXXX represents the total number of running...

Страница 25: ...program This function allows the user to select one of ten of the user defined built in programs This program is then accessed in Function Mode under Program Run 9 5 2 Edit program This function allow...

Страница 26: ...ile and will remain in the fixture s memory even when the power to the unit is switched off Memory is backed up and retain by an internal power source that should last about five years Remote DMX addr...

Страница 27: ...5 When set to 8 you can adjust the starting address between 256 and 511 3 Use channel 3 to set your desired DMX starting address For example If you want to set the starting address to 57 set channel 1...

Страница 28: ...manual settings This unit will keep and retain the last DMX command in the event of DMX signal failure To reset the fixture you must turn the power off DMX CHANNEL TRAITS The charts below and on the...

Страница 29: ...is mode channel one controls all the red LEDs channel two controls all the green LEDs channel three controls all the blue LEDs and channel four controls the master dimming level 6 Channel mode In this...

Страница 30: ...www ElationLighting com 12 Channel mode In this mode channels each color is controlled individually 15 Channel mode In this mode channels each color is controlled individually using channels 1 12 and...

Страница 31: ...nternal program 6 191 220 Internal program 7 4 13 221 255 Internal program 8 1 1 0 255 Red group1 2 2 0 255 Green group1 3 3 0 255 Blue group1 4 4 0 255 Red group2 5 5 0 255 Green group2 6 6 0 255 Blu...

Страница 32: ...ne or a maximum of 64 scenes Keep in mind that a scene can only be access when it is stored in a Program If you wish to build a static scene a scene consisting of no movement for a logo or gobo projec...

Страница 33: ...inside one of the fixture s scene storage banks Many people may find this procedure easier and quicker than using the on board menu functions as in Step 1 To store a scene from an external DMX control...

Страница 34: ...ollow the procedure below Access the main menu and use the Up and Down to toggle to Function Mode and tap the Enter button In the next screen select Auto Program and tap the Enter button There are now...

Страница 35: ...n place by 4 screws on the back of the lens assembly To remove the cover 1 Remove the securing fasteners in a counter clockwise direction 2 Once the fasteners are removed lift the cover straight up to...

Страница 36: ...not show any damage material fatigue or sediments Never remove the ground prong from the power cable Further instructions depending on the installation spot and usage have to be adhered by a skilled...

Страница 37: ...with the product Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number ha...

Страница 38: ...ding warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or f...

Страница 39: ...ELAR Tri Brick Elation Professional Los Angeles Ca 38 www ElationLighting com 16 PHOTOMETRIC DATA...

Страница 40: ...ELAR Tri Brick Elation Professional Los Angeles Ca 39 www ElationLighting com 17 DIMENSIONAL DRAWINGS...

Страница 41: ...ELAR Tri Brick Elation Professional Los Angeles Ca 40 www ElationLighting com 18 CIRCUIT SCHEMATIC...

Страница 42: ...annel mode DMX Drive Standard DMX 512 3 pole IP Rated Locking Connector Pin 3 Pin 2 Ground Pin 1 Color Mixing RGB Color Additive Mixing Beam Angle 18 Beam Angle 35 Field Angle 25 Lens Fuse GMA 220v 2A...

Страница 43: ...ELAR Tri Brick Elation Professional Los Angeles Ca 42 www ElationLighting com...

Страница 44: ...Rev 2 26 2010 visage Version 1 0 Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www ElationLighting com Info ElationLighitng com...

Отзывы: