Elation Elar Quad Par Скачать руководство пользователя страница 17

 
 

w w w . e l a t i o n l i g h t i n g . c o m    

 

                                                                                                                                                                                        17

                                                               

ELAR   QUAD   PAR

™   

User   Manual   2.0

 

DMX ADDRESSING 

All fixtures should be given a DMX starting address when using a DMX controller, so the 

correct  fixture  responds  to  the  correct  control  signal.  This  digital  starting  address  is  the 

channel number from which the fixture starts to “listen” to the digital control information sent 

out  from  the  DMX  controller.  The  allocation  of  this  starting  DMX  address  is  achieved  by 

setting the correct DMX address on the digital display located on the back of the fixture. 

 

You can set the same starting address for all fixtures or a group of fixtures, or set different 

address  for  each  individual  fixture.  Be  advised  that  setting  all  fixtures  to  the  same  DMX 

address will subsequently control all fixtures in the same fashion, in other words, changing 

the settings of one channel will affect all the fixtures simultaneously. 

 

If  you  set  each  fixture  to  a  different  DMX  address,  each  unit  will  start  to  “listen”  to  the 

channel number you have set, based on the quantity of control channels (DMX channels) of 

each fixture. That means changing the settings of one channel will only affect the selected 

fixture. 

 

In the case of the 

ELAR QUAD PAR™,

 when in 36 channel mode (default can also be set to 

4, 5, 6, or 8), you should set the starting DMX address of the first unit to 1, the second unit to 

37 (1 + 36), the third unit to 73 (37 + 36), the fourth unit to 109 (73 + 36) and so on. 

 

Note: 

During start-up the 

ELAR QUAD PAR™

 will automatically detect whether a DMX data 

signal is being received or not. If DMX data signal is being received, the display will show 

"Addr=XXX"  (XXX 

representing the actual DMX address). If the fixture is not receiving a 

DMX signal the display will flash. If your fixture is connected to a DMX controller and the 

display is flashing (not receiving a DMX signal), please check the following:

 

-    The XLR input plug (cable with DMX signal from controller) is not connected or is not 

inserted completely into the DMX input jack of the fixture. 

-

  The DMX controller is switched off or defective. 

-

  The DMX cable or connector is defective. 

-

  A DMX terminator has been inserted into the last fixture in your DMX chain. 

 

 

Содержание Elar Quad Par

Страница 1: ...ELAR QUAD PAR user manual 2 0 E L A TI ON ELAR QUAD PAR user manual 2 0...

Страница 2: ...wledged All non ELATION brands and product names are trademarks or registered trademarks of their respective companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all lia...

Страница 3: ...0 C O N T E N T S General Information 4 Warranty 6 Safety Instructions 7 General Guidelines 8 Features 9 Fixture Overview 10 Installation 11 Understanding DMX 14 Fixture Menu 18 DMX Channel Values 27...

Страница 4: ...of protection The first digit Foreign Bodies Protection indicates the extent of protection against particles entering the fixture and the second digit Water Protection indicates the extent of protecti...

Страница 5: ...the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number mu...

Страница 6: ...t forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professional w...

Страница 7: ...manufactures warranty and increase the risk of damage and or personal injury Never look directly into the light source of this fixture to prevent risk of injury to your retina which may induce blindn...

Страница 8: ...llation and or operation without proper knowledge of how to do so Do not permit operation by persons who are not qualified for operating this type of theatrical fixture Most damages are the result of...

Страница 9: ...Aluminium Body USITT DMX 512 with 4 5 6 8 and 36 DMX Channel Operation Strobe Effect with 1 18 flashes per second 0 100 Dimming and Blackout for all LEDs Excellent Color Mixing and Chase Effect Singl...

Страница 10: ...exit the current command 6 UP Button Used to toggle forward through the menu functions and settings 7 DOWN Button Used to toggle down or back through the menu functions and settings 8 ENTER Button Us...

Страница 11: ...ersonnel might reach the fixture Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 160 lbs 73 kgs Fixture i...

Страница 12: ...ection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully operatio...

Страница 13: ...al 3 Safety Cable included INSTALLATION VIA MOUNTING BRACKET Attach clamp to center 13 hole on the Mounting Bracket Pull the included Safety Cable underneath the Mounting Bracket and over the trussing...

Страница 14: ...ne with a Y style connector The order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a starting DMX address of 1 may be placed a...

Страница 15: ...l linking The cable that should be used is two conductor shielded DMX cable with XLR input and output connectors Always be sure daisy chain your in and out data connections never split or Y your DMX c...

Страница 16: ...n XLR connectors for DATA transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor m...

Страница 17: ...o the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the ca...

Страница 18: ...and make all necessary adjustments to the ELAR QUAD PAR During normal operation pressing the MENU button once will access the fixture s main menu Once in the main menu you can navigate through the dif...

Страница 19: ...r 3 seconds to activate SET CHAN 4CH 5CH 6CH 8CH 36CH DMX Channel Mode FAIL OFF HOLD AUTO Status while there is no DMX DFSE ON OFF Default setting POHO ON OFF Power on to preserve the MANL settings VE...

Страница 20: ...function you can adjust the desired DMX address via the Control Board 1 Select VALU by pressing UP or DOWN buttons 2 Press ENTER adjust the DMX address by pressing UP or DOWN button 3 Press ENTER to c...

Страница 21: ...adjust the starting address between 1 and 255 When set to 8 you can adjust the starting address between 256 and 510 Set the DMX value of channel 3 to the desired starting address If you want to set t...

Страница 22: ...ure the display 1 Select FLIP by pressing UP or DOWN buttons 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON to enable this function or press DOWN to select OFF 4 Press ENTER to conf...

Страница 23: ...OFF HOLD or AUTO the default is HOLD 4 Press ENTER to confirm or press MENU to return to the main menu Restore Factory Settings With this function you can restore the factory settings of the device Al...

Страница 24: ...or DOWN button to select TIME 3 Press MODE ESC to enter the main menu display flashing 4 Press UP or DOWN button to select TIME Fixture Running Time With this function you can display the running time...

Страница 25: ...splay shows S XX X stands for the total amount of steps you want to save so you can call up to 48 scenes in RUN For example if the XX is 05 it means that RUN will run the first 5 scenes you saved in E...

Страница 26: ...ngs for the scene you are editing the display will change to the next scene automatically 10 Repeat step 3 8 to edit other scenes you can edit and save a maximum of 48 scenes 11 Press MENU to exit The...

Страница 27: ...w w w e l a t i o n l i g h t i n g c o m 27 ELAR QUAD PAR User Manual 2 0 D M X C H A N N E L F U N C T I O N S A N D V A L U E S...

Страница 28: ...w w w e l a t i o n l i g h t i n g c o m 28 ELAR QUAD PAR User Manual 2 0...

Страница 29: ...w w w e l a t i o n l i g h t i n g c o m 29 ELAR QUAD PAR User Manual 2 0 L E D N U M B E R S 1 9 3 4 5 2 8 7 6...

Страница 30: ...fer to the following points during routine inspections A detailed electric check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and preve...

Страница 31: ...ay vary depending on several factors including but not limited to Environmental Conditions Power Voltage Usage Patterns On Off Cycling Control and Dimming OPTICAL 11 Beam Angle 20 Field Angle COLOR MI...

Страница 32: ...ED LEDs 8810 2326 986 GREEN LEDs 12520 2989 1374 BLUE LEDs 2670 690 284 WHITE LEDs 17980 3683 1691 FULL ON LEDs 36690 9010 3849 PHOTOMETRIC DATA DIMENSIONAL DRAWINGS millimeters Please Note Specificat...

Страница 33: ...n l i g h t i n g c o m 33 ELAR QUAD PAR User Manual 2 0 CIRCUIT SCHEMATIC Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any pri...

Страница 34: ......