9.  DISPLAY MENU   

 

Default settings shaded. 

 

 

Remarks: 

1)  If the fixture does not receive a DMX signal the menu display will flash 

 

repeatedly. 

2)   TIME: Adjust the hold time for each scene in built-in chase programs. 

3)  FADE: Adjust the fade time between each scene in the built-in programs.  

 

9.1 “MODE” - Function Mode: 

9.1.1  <ADDR> - DMX address setting – 

This function is used to set or adjust the 

fixture’s starting DMX address. Every device controlled by DMX has to have a unique 

starting address. The addressing feature is what allows DMX to function properly. The 

DMX address of a fixture is what allows it to communicate with a controller properly. The 

DMX addressing also allows the fixture to ignore any DMX information coming from the 

controller that is not meant specifically for the fixture. Because each fixture is connected 

VALU 

A001

~AXXX    (AXXX) 

DMX address setting 

SLAV 

ON/

OFF

 

Set as Slave 

<ADDR> 

RDMX 

ON

/OFF 

Change address via DMX 

<RUN> 

AUTO 

ALON

/MAST 

Run Auto program 

VALU 

D-XX    D-00(DXXX) 

Display DMX value 

FLIP 

ON/

OFF

 

Flip display 

MODE 

<DISP> 

D ON 

ON

/OFF 

Delay shutting off LED display 

<CHAN> 

4CH

/5CH/7CH/9CH 

DMX channel Mode 

<FAIL> 

OFF/

HOLD

/AUTO 

Status while there is no DMX 

<DFSE> 

ON/

OFF

 

Default setting 

SET 

<VER> 

V-1.0~V-9.9 

Software version 

MANL 

<CH01> 
~<CH09> 

01 XX (00~FFH) 
09 XX (00~FFH) 

Manual adjust intensity 

<LIFE> 

0000~9999(hours) 

Life time of machine running 

<CODE> 

CXXX 

Password of clear time ”038” 

TIME 

<CLFE> 

ON/

OFF

 

Clear machine running time 

<STEP> 

S-01~

S-48

 

 

Select steps of program 

C-01~C-09 

01 XX (00~FFH) 
09 XX (00~FFH) 

FADE 

XXX 

EDIT  <SC01> 

~<SC48> 

TIME 

XXX.X (000.1s~999.9s) 

Edit the internal scenes 

Содержание ELAR 108PAR RGBW

Страница 1: ...Rev 01 08 2010 visage Version 1 1 ELAR 108PAR RGBW Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 www elationlighting com...

Страница 2: ...ELAR 108PAR RGBW Elation Professional Los Angeles Ca 1 www ElationLighting com...

Страница 3: ...w 9 6 Mounting and Installation 12 7 Understanding DMX 15 a DMX Cables 15 b DMX Terminator 16 c 3 Pin to 5 Pin Conversion 17 d Fixture DMX Addressing 16 8 Display Indicators 19 9 Display Menu 20 10 DM...

Страница 4: ...ssary to operate the fixture have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Inside the box you should fin...

Страница 5: ...under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the p...

Страница 6: ...allation guide described in chapter six of this manual Operating the ELAR 108PAR RGBW without suited safety aids such as safety cables or clamps can increase the risk of damage and or personal injury...

Страница 7: ...pe of service or any cleaning procedure 13 Only handle the power cord by the plug Never pull out the plug by tugging the wire portion of the cord 14 Please be aware that damages caused by modification...

Страница 8: ...ogrammed colored macros Strobe effect with a maximum flash rate of 18fps DMX controlled operation or stand alone operation with Master Slave function 7 built in programs can be called up via DMX contr...

Страница 9: ...xtreme heat moisture or dust The minimum distance between the fixture and a wall or flat surface should be at least 0 5 meter about 1 5ft See page 12 Always install the fixture with an appropriately r...

Страница 10: ...ELAR 108PAR RGBW Elation Professional Los Angeles Ca 9 www ElationLighting com 5 FIXTURE OVERVIEW...

Страница 11: ...e in the DMX chain To maintain the integrity of the IP rating only use proper Elation IP rated DMX cables 5 MENU Button This button is used to access the fixtures menu functions 6 Up Button The up but...

Страница 12: ...connectors to maintain the IP rating 11 DMX In Lead This lead is the main DMX input lead When the unit is the first in a chain or the only fixture to be used with a DMX controller be sure to use the...

Страница 13: ...ng removing or servicing the fixture Refer to regulations BGV C1 formerly VBG 70 and DIN VDE0711 217 for proper installation in Europe To ensure proper installation only qualified staff should attempt...

Страница 14: ...mounting always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure See the image below Clamp Mounting The ELAR 108PAR RGB...

Страница 15: ...safety measure be sure to attach at least one properly rated safety cable to the fixture See illustrations below Securing the ELAR 108PAR RGBW Always be sure to secure your fixture with a safety cabl...

Страница 16: ...d in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the middle Th...

Страница 17: ...les provided through Elation Always be sure to daisy chain your in and out data connections never split or Y your DMX connections unless you are using an approved DMX splitter such as the Elation Opto...

Страница 18: ...digital control information sent out from the DMX controller The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of t...

Страница 19: ...not receiving a DMX signal the display will flash A XXX XXX representing the actual DMX address If your fixture is connected to a DMX controller and the display is flashing not receiving a DMX signal...

Страница 20: ...indicator on the display This indicator is designed to give a quick visual indication of the fixtures DMX status The illustration below details the functionality of the LED indicators The LED indicat...

Страница 21: ...ing also allows the fixture to ignore any DMX information coming from the controller that is not meant specifically for the fixture Because each fixture is connected VALU A001 AXXX AXXX DMX address se...

Страница 22: ...ve for operation in Master Slave mode Each slave setting will have a different function for a dynamic lightshow without a controller RDMX Address via DMX This function allows the DMX address to remote...

Страница 23: ...ring normal operation to avoid excessive light in situations that require an extremely dark environment This function will adjust the time delay the fixture will remain on before it turns off This fun...

Страница 24: ...ime functions associated with the fixture LIFE 0000 9999 Hours This function tracks the running time of the fixture from the point it was last cleared Where XXXX represents the total number of running...

Страница 25: ...program This function allows the user to select one of ten of the user defined built in programs This program is then accessed in Function Mode under Program Run 9 5 2 Edit program This function allo...

Страница 26: ...tile and will remain in the fixture s memory even when the power to the unit is switched off Memory is backed up and retain by an internal power source that should last about five years Remote DMX add...

Страница 27: ...55 When set to 8 you can adjust the starting address between 256 and 511 3 Use channel 3 to set your desired DMX starting address For example If you want to set the starting address to 57 set channel...

Страница 28: ...s unit will keep and retain the last DMX command in the event of DMX signal failure To reset the fixture you must turn the power off DMX CHANNEL TRAITS The charts below and on the preceding pages outl...

Страница 29: ...l 2 Green 0 255 Green 0 Black 255 100 Green Channel 3 Blue 0 255 Blue 0 Black 255 100 Blue Channel 4 White 0 255 White 0 Black 255 100 White 5 Channel mode In this mode channel one controls all the re...

Страница 30: ...n 0 Black 255 100 Green Channel 3 Blue 0 255 Blue 0 Black 255 100 Blue Channel 4 White 0 255 White 0 Black 255 100 White Channel 5 General dimming 0 255 Dimming 0 Black 255 100 7 Channel mode In this...

Страница 31: ...White Channel 5 Color Temperature 0 No function 1 255 Color Temperature 2700K 7200K Channel 6 Color macros 0 No function 1 7 R02 Bastard Amber 8 15 R04 Medium Amber 16 23 R09 Pale Amber Gold 24 31 R3...

Страница 32: ...1 Primary Green 216 223 L200 Double CTB 224 231 L201 Full CTB 232 239 L202 1 2 CTB 240 247 L119 Dark Blue 248 255 White Channel 7 General dimming speed 0 255 Dimming 0 Black 255 100 Speed from slow to...

Страница 33: ...nel 1 Red LED 0 255 Red 0 Black 255 100 Red Channel 2 Green LED 0 255 Green 0 Black 255 100 Green Channel 3 Blue LED 0 255 Blue 0 Black 255 100 Blue Channel 4 White LED 0 255 White 0 Black 255 100 Whi...

Страница 34: ...11 R59 Indigo 112 119 R361 Hemsley Blue 120 127 R362 Tipton Blue 128 135 R64 Light Steel Blue 136 143 R67 Light Sky Blue 144 151 R68 Sky Blue 152 159 R69 Brilliant Blue 160 167 R76 Light Green Blue 16...

Страница 35: ...fect Channel 8 Shutter strobe 0 31 Blackout All LEDs Off 32 63 Open LEDs Active 64 95 Strobe effect slow to fast 96 127 Open LEDs Active 128 159 Pulse effect in sequences 160 191 Open LEDs Active 192...

Страница 36: ...one or a maximum of 64 scenes Keep in mind that a scene can only be access when it is stored in a Program If you wish to build a static scene a scene consisting of no movement for a logo or gobo proje...

Страница 37: ...hat scene can then be sent to the fixture and be stored inside one of the fixture s scene storage banks Many people may find this procedure easier and quicker than using the on board menu functions as...

Страница 38: ...ng a Program To initiate a program follow the procedure below Access the main menu and use the Up and Down to toggle to Function Mode and tap the Enter button In the next screen select Auto Program an...

Страница 39: ...cover is held in place by two turn locking fasteners To remove the cover 1 Turn the locking fasteners in a counter clockwise direction 2 Once the fasteners are loose lift the cover straight up to exp...

Страница 40: ...t not show any damage material fatigue or sediments Never remove the ground prong from the power cable Further instructions depending on the installation spot and usage have to be adhered by a skilled...

Страница 41: ...with the product Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number h...

Страница 42: ...uding warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or...

Страница 43: ...ELAR 108PAR RGBW Elation Professional Los Angeles Ca 42 www ElationLighting com 16 PHOTOMETRIC DATA...

Страница 44: ...ELAR 108PAR RGBW Elation Professional Los Angeles Ca 43 www ElationLighting com 17 DIMENSIONAL DRAWINGS...

Страница 45: ...ELAR 108PAR RGBW Elation Professional Los Angeles Ca 44 www ElationLighting com 18 CIRCUIT SCHEMATIC...

Страница 46: ...4 default Channel mode DMX Drive Standard DMX 512 3 pole IP Rated Locking Connector Pin 3 Pin 2 Ground Pin 1 Color Mixing RGBW Color Additive Mixing Beam Angle 13 Beam Angle 25 Field Angle 15 Lens Fu...

Страница 47: ...ELAR 108PAR RGBW Elation Professional Los Angeles Ca 46 www ElationLighting com...

Страница 48: ...Rev 01 08 2010 visage Version 1 1 Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www ElationLighting com Info ElationLighitng com...

Отзывы: