background image

 
 

 
 

 

 

 

 

 

 

 

E SPOT III™ 

user manual

   

   

E

LA

TI

ON

 

|

 

SP

O

T I

II

 

|

 

u

se

r m

an
u

al

 

Содержание E SPOT III

Страница 1: ...E SPOT III user manual E L A TI ON E SPOT III user manual...

Страница 2: ...mpanies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance...

Страница 3: ...E N T S General Information 4 Warranty 6 Safety Instructions 7 General Guidelines 8 Fixture Overview 9 Fixture Installation 10 Fixture Menu 13 DMX Channel Functions And Values 21 Error Codes 24 Clean...

Страница 4: ...maintenance UNPACKING Every fixture has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shippin...

Страница 5: ...ase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the retur...

Страница 6: ...by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warra...

Страница 7: ...allation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture...

Страница 8: ...n without knowledge how to do so DO NOT permit operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessionals Consistent opera...

Страница 9: ...nual F I X T U R E O V E R V I E W 1 Lens 2 LCD Control Display 3 ENTER Button 4 LEFT Button 5 DOWN Button 6 RIGHT Button 7 MODE ESC Button 8 UP Button 9 Handles 10 3pin DMX OUT 11 3pin DMX IN 12 5pin...

Страница 10: ...ed protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture is 14...

Страница 11: ...safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fu...

Страница 12: ...omega brackets using a M10 screw fitted through the center hole of the Omega Bracket Be sure to attach the included Safety Cable to the fixture using the safety cable rigging point integrated in the...

Страница 13: ...he fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adju...

Страница 14: ...1 Software Versions 2U01 V1 2 1 3U01 V1 2 1 4U01 V1 2 1 5U01 V1 2 1 Error Info Error Record 1 Error Record 10 Error Info History Personality Status Settings Address via DMX ON OFF Set Address Via DMX...

Страница 15: ...er Mode Standard Mode Select DMX Channel Modes Basic Mode Extended Mode User Mode A User Defined Channel Assignment User Mode B User Mode C Edit User Mode Edit User Mode A Max Channel XX PAN CH01 Edit...

Страница 16: ...value of 8 and then set Channel 3 to a value of 164 256 164 420 5 After setting Channel 3 to the desired DMX address value wait for approximately 20 seconds for the fixture to complete the address res...

Страница 17: ...flat clear surface With the individual functions you can focus the light on a flat surface wall and perform fine adjustments EFFECT ADJUST Calibration ONLY QUALIFIED TECHNICIANS SHOULD PERFORM THIS FU...

Страница 18: ...ster unit sends the 3 program parts in a continuous loop The Slave unit receives data from the Master unit according to the group which the Slave unit was assigned to If e g a Slave unit is set to Sla...

Страница 19: ...as the master units R H II ENTER to confirm R H II MODE ESC in order to return to the main menu 4 Program Selection for Edit Program R B 9J WEdit Program R H II ENTER to confirm R B 9J Edit Program R...

Страница 20: ...Programs continued Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes scenes 12 13 14 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto P...

Страница 21: ...29 RED 30 44 BLUE 45 59 GREEN 60 74 YELLOW 75 89 MAGENTA 90 104 ORANGE 105 119 LIGHT BLUE 120 127 PINK 128 189 Clockwise Color Wheel Rotation from FAST to SLOW 190 193 NO Rotation 194 255 Counterclock...

Страница 22: ...o 2 144 151 Prism Gobo Macro 3 152 159 Prism Gobo Macro 4 160 167 Prism Gobo Macro 5 168 175 Prism Gobo Macro 6 176 183 Prism Gobo Macro 7 184 191 Prism Gobo Macro 8 192 199 Prism Gobo Macro 9 200 207...

Страница 23: ...to MIN Diameter 192 223 Pulse Closing FAST to SLOW 224 255 Pulse Opening SLOW to FAST 13 15 19 PAN TILT MOVEMENT SPEED 0 225 MAX to MIN Speed 226 235 Blackout with PAN and TILT Movement 236 245 Blacko...

Страница 24: ...flash repeated 5 times If an error does occur during the initial start up procedure the fixture will self generate a second reset signal and try to realign all the motors and correct the errors If the...

Страница 25: ...r all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points du...

Страница 26: ...d Strobe Variable Dimming Curves COLOR 8 Dichroic Colors GOBOS 7 Interchangeable Rotating Indexing Gobos CONTROL CONNECTIONS 3 DMX Channel Modes 14 16 20 RDM Remote Device Management 6 Button Touch Co...

Страница 27: ...Diameter ID Image Diameter Due to varying manufacturing processes it is highly recommended to provide a gobo and holder sample from the fixture to 3rd party custom gobo vendors for accurate sizing PHO...

Страница 28: ...o n l i g h t i n g c o m 28 E SPOT III User Manual DIMENSIONAL DRAWINGS Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior...

Страница 29: ...O N A L A C C E S S O R I E S ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp EWDMXSYSTEM Wireless DMX System 1 Transmitter 1 Receiver AC3PDMX5PRO 5 ft 1 5m 3pin PRO DMX Cable A...

Страница 30: ......

Отзывы: