background image

 

 

w w w . e l a t i o n l i g h t i n g . c o m  

 

                                              

5

                        DTW PAR 300™ User Manual

 

CUSTOMER SUPPORT 

Elation Professional

®

 provides a customer support line, to provide set up help and 

to answer any question should you encounter problems during your set up or 
initial operation. You may also visit us on the web at 

www.elationlighting.com

 for 

any comments or suggestions. For service related issue please contact Elation 
Professional®. 

ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST 
Voice: 323-582-3322

   

 

 

 

Fax: 323-832-9142

 

E-mail: 

[email protected] 

ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET   
Voice: +31 45 546 85 30   

 

 

Fax: +31 45 546 85 96 

E-mail: 

[email protected]

 

 

WARRANTY REGISTRATION

 

Please  complete and mail in the enclosed warranty card or register online: 

http://www.elationlighting.com/Login.aspx

  to validate your purchase. All 

returned service items whether under warranty or not, must be freight pre-paid 
and accompany a return authorization (R.A.) number. The R.A. number must be 
clearly written on the outside of the return package. A brief description of the 
problem as well as the R.A. number must also be written down on a piece of 
paper and included in the shipping container. If the unit is under warranty, you 
must provide a copy of your proof of purchase invoice. Items returned without a 
R.A. number clearly marked on the outside of the package will be refused and 
returned at customer’s expense. You may obtain a R.A. number by contacting 
customer support. 

I M P O R T A N T   N O T I C E !  

There are no user serviceable parts inside this unit.  Do not  attempt any repairs 

yourself; doing so will void your manufactures warranty. Damages resulting from 

modifications to this fixture and/or the disregard of safety and general user 

instructions found in this user manual void the manufactures warranty and are 

not subject to any warranty claims and/or repairs. 

Содержание DTW PAR 300

Страница 1: ...DTW PAR 300 user manual E L A TI ON DTW PAR 300 user manual...

Страница 2: ...and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly...

Страница 3: ...User Manual C O N T E N T S General Information 4 Warranty 6 Safety Instructions and Guidelines 7 Overview 9 Installation 10 System Menu 14 DMX Channel Functions And Values 17 Cleaning and Maintenance...

Страница 4: ...fety during use and maintenance UNPACKING Every fixture has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occu...

Страница 5: ...ase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the retur...

Страница 6: ...by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warr...

Страница 7: ...this fixture and only the original rigging parts omega brackets included with this fixture should be used for installation Any modifications to the fixture and or the mounting hardware included will...

Страница 8: ...all for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always install fixture with an appropriately rated safety ca...

Страница 9: ...w w w e l a t i o n l i g h t i n g c o m 9 DTW PAR 300 User Manual O V E R V I E W...

Страница 10: ...tection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture is 5 to 113...

Страница 11: ...e fixture provides an integrated mounting dual bracket yoke When mounting this fixture to truss be sure to secure an appropriately rated clamp using a M10 screw fitted through the center hole of the d...

Страница 12: ...nspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully oper...

Страница 13: ...R 300 User Manual POWER LINKING 7 units 120V 14 units 240V u NOTE USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO DTW PAR 300 POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY ALWAYS CHECK MAX A...

Страница 14: ...you can navigate through the different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and...

Страница 15: ...CH CH 01 03 04 05 06 07 08 Set DMX Channel Mode SLAVE M O D E Set unit to Slave Mode STATIC Dim 000 255 Flash000 255 CW 000 255 WW 000 255 Amber000 255 Set Dimmer Strobe Cool White Warm White and Ambe...

Страница 16: ...lect Fade Speed FLASH Select Shutter Strobe Effects see DMX traits for values AUTOLOCK OFF ON When ON LCD control display locks after 55 seconds of non activity Press hold MODE button for 3 seconds to...

Страница 17: ...w w w e l a t i o n l i g h t i n g c o m 17 DTW PAR 300 User Manual Dim Curve DIMMER Select desired DIMMER MODE Standard Stage TV Architectural Theatre...

Страница 18: ...0 255 WARM WHITE All LEDs Warm White 0 Black 255 100 3 3 3 3 3 3 0 255 AMBER All LEDs Amber 0 Black 255 100 1 4 4 0 255 DIM TO WARM All LEDS 1 800K 3 200K 0 Black 255 100 4 5 SHUTTER STROBE 0 31 NO Fu...

Страница 19: ...er all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points d...

Страница 20: ...im to Warm Channel Control 1 800K 3 000K Electronic Strobe and Variable Dimming Curves CONTROL CONNECTIONS 7 DMX Channel Modes 8 Total Channels 4 Button Control Panel and LCD Menu Display RDM Remote D...

Страница 21: ...iameter 3 m 9 8 ft 4 m 13 1 ft 5 m 16 4 ft 23 Beam Diameter 1 29 4 2 1 73 5 7 2 17 7 1 44 Field Diameter 3 26 10 7 3 26 10 7 4 07 13 4 lux fc lux fc lux fc WW LEDs 1 935 180 1 130 105 630 59 CW LEDs 1...

Страница 22: ...o n l i g h t i n g c o m 22 DTW PAR 300 User Manual DIMENSIONAL DRAWINGS Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior...

Страница 23: ...ER CODE ITEM NARROW CLAMP P PRO 2 Wrap Around Clamp SIXPAR300 GFH Gel Frame and Holder Kit SIXPAR BD300 Barn Door Gel Frame Holder Kit Required Not Included AC3PDMX5PRO 5 ft 1 5m 3pin PRO DMX Cable AC...

Страница 24: ......

Отзывы: