Design Beam 1200C™
©Elation Professional® 42 Design Beam 1200C™
A Master unit can send up to 3 different data groups to the Slave units, i.e. a Master unit can
start 3 different Slave units, which run 3 different programs. The Master unit sends the 3
program parts in a continuous loop.
The Slave unit receives data from the Master unit according to the group which the Slave
unit was assigned to. If e.g. a Slave unit is set to “Slave 1” in the menu “Set to Slave”, the
Master unit sends “Auto Program Part 1” to the Slave unit. If set to “Slave 2”, the Slave unit
receives “Auto Program Part 2”.
To start a Auto Program please proceed as follows:
1. Slave-Setting
• Select “Function Mode” by turning the encoder.
• Press the Enter button to confirm.
• Select “Set to slave” by turning the encoder.
• Press the Enter button to confirm.
• Turn the encoder to select “Slave 1”, “Slave 2” or “Slave 3”.
• Press the Enter button to confirm.
• Press the Mode/Esc button in order to return to the main menu.
2. Automatic Program Run
• Select “Function Mode” by turning the encoder.
• Press the Enter button to confirm.
• Select “Auto Program” by turning the encoder.
• Press the Enter button to confirm.
• Turn the encoder to select “Master” or “Alone”. The selection "Alone" means Stand
Alone-mode and "Master" that the device is defined as master.
• Press the Enter button to confirm.
• Press the Mode/Esc button in order to return to the main menu.
Содержание Design Spot 1200C
Страница 2: ...Design Beam 1200C Elation Professional 2 Design Beam 1200C...
Страница 58: ...Design Beam 1200C Elation Professional 58 Design Beam 1200C 20 PHOTOMETRIC DATA...
Страница 59: ...Design Beam 1200C Elation Professional 59 Design Beam 1200C 21 DIMENSIONAL DRAWINGS...
Страница 60: ...Design Beam 1200C Elation Professional 60 Design Beam 1200C 22 CIRCUIT SCHEMATIC...
Страница 63: ...Design Beam 1200C Elation Professional 63 Design Beam 1200C...