background image

©

Elation

®

  -  www.elationlighting.com  - Active Scan 250™ Instruction Manual Page 3

•   Micro-Stepping Motors for Smooth Color and Gobo Transitions
•   DMX-512 Protocol Compatible (Uses Six DMX Channels)
•   7 Gobo Patterns Plus Spot 
•   11 Colors Plus White
•  Master/Slave Operation
•  Internal Microphone 
•  Variable Speed Strobe Function
•   Rotating Gobos and Gobo Shake
•  Replaceable Gobos
•  LED Display Menu
•  ZB-MSD250
•  2 Year Warranty

 Active Scan 250™  

 

 

 

         Features

The Active Scan 250™ carries a two year limited warranty. Please fill 
out the enclosed warranty card to validate your purchase. All returned 
service items whether under warranty or not, must be freight pre-paid 
and accompany a return authorization (R.A.) number. The R.A. num-
ber  must  be  clearly  written  on  the  outside  of  the  return  package.  A 
brief description of the problem as well as the R.A. number must also 
be written down on a piece of paper included in the shipping carton. 
If the unit is under warranty, you must provide a copy of your proof of 
purchase  invoice.  You  may  obtain  a  R.A.  number  by  contacting  our 
customer support team on our support number. All packages returned 
to the service department not displaying a R.A. number on the outside 
of the package will be returned to the shipper.

  Active Scan 250™  

  

         Product Registration

©

Elation

®

  -  www.elationlighting.com  - Active Scan 250™ Instruction Manual Page 4

To optimize the performance of this product, please read these operating 
instructions carefully to familiarize yourself with the basic operations of 
this unit. These instructions contain important safety information regard-
ing the use and maintenance of this unit. Please keep this manual with 
the unit, for future reference.

  Active Scan 250™ 

 

          General Instructions

Active Scan 250™               Discharge Lamp Warning

This fixture is fitted with a discharge lamp which 
are  highly  susceptible  to  damage  if  improperly 
handled.  Never  touch  the  lamps  with  your  bare 
fingers  as  the  oil  from  your  hands  will  shorten 
lamp  life.  Also,  never  move  the  fixture  until  the 
lamps have had ample time to cool. Remember, 
lamps  are  not  covered  under  warranty  condi-
tions.

This unit emits intense UV radiation which is harmful to the eyes and 
skin.  The  intense  luminance  of  the  lamp  can  cause  severe  damage 
to the retina. Never operate this unit without it’s covers, these covers 
have been specially designed to shield against UV radiation.

Epileptic Warning: 

Those suffering from epilepsy should avoid looking 

directly into the lamp at all times.

Avoid switch the fixture on and off repeatedly in short intervals as this 
will reduce lamp life and intensity.
To achieve the intensity associated with discharge lamps, these lamps  
use gas sealed in a high pressure environment to emit a brilliant output.  
Due to the high pressure involved with the construction of the lamp, 
the  lamp  may  explode  during  prolonged  extensive  use.  This  risk  is 
increased with age, added care is encouraged when dealing with older 
lamps.  Extreme  caution  should  be  used  when  operated  this  or  any 
fixture fitted with a gas discharge lamp. Never open this unit while in 
use. 

PLEASE READ THE PROPER LAMP REPLACEMENT INSTRUCTIONS 
LOCATED  ON PAGE 16.

Содержание Active Scan 250

Страница 1: ...ght show This unit can also run as a stand alone sound active unit or in a Master Slave configuration The Active Scan 250 comes with several built in programs and is best used in multiples of four For best results use fog or special effects smoke to enhance the beams projections Customer Support Elation provides a customer support line to provide help and to answer any question should you encounte...

Страница 2: ...f with the basic operations of this unit These instructions contain important safety information regard ing the use and maintenance of this unit Please keep this manual with the unit for future reference Active Scan 250 General Instructions Active Scan 250 Discharge Lamp Warning This fixture is fitted with a discharge lamp which are highly susceptible to damage if improperly handled Never touch th...

Страница 3: ...leaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to ...

Страница 4: ...ssing For example a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Active Scan 250 Set Up Data Cable DMX Cable Requirements For DMX and Master Slave Opera...

Страница 5: ...lace of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting stan dard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a proper cable conversion Elation www elationlighting com Active Scan 250 Instruction Manual Page 9 Elation www elationlighting com Active Scan 25...

Страница 6: ...s mode allows a single unit to run to the beat of the music Only use this mode when running a single unit or when running several units as individuals 1 To activate this unit in stand alone sound active mode use the Up or Down buttons to scroll through the function LED until F4 appears in the display 2 Press Yes then press Enter The unit will react to the low frequencies of music via the internal ...

Страница 7: ...g com Active Scan 250 Instruction Manual Page 13 Elation www elationlighting com Active Scan 250 Instruction Manual Page 14 Active Scan 250 DMX Traits Channel Value Function 4 112 127 GOBO 7 128 132 OPEN 133 144 GOBO 1 SHAKE 145 156 GOBO 2 SHAKE 157 168 GOBO 3 SHAKE 169 180 GOBO 4 SHAKE 181 192 GOBO 5 SHAKE 193 210 GOBO 6 SHAKE 211 217 GOBO 7 SHAKE 218 219 OPEN 220 249 GOBO WHEEL SCROLL 250 255 SO...

Страница 8: ...re to follow the proper handling procedures that deal with discharge lamps 2 Unscrew and remove the two thumb screws at the rear of the unit 3 After removing the thumb screws slide the lamp socket assembly out 4 Carefully remove the old lamp NEVER TOUCH A DISCHARGE LAMP WITH YOUR BARE HANDS NEVER DISCARD A DISCHARGE LAMP IN THE TRASH FOR PROPER DISPOSAL INSTRUCTIONS PLEASE REFER TO THE INSTRUCTION...

Страница 9: ... Manual Page 18 Elation www elationlighting com Active Scan 250 Instruction Manual Page 17 Fuse Replacement Locate and remove the unit s power cord Once the cord has been removed locate the fuse holder inside the power socket Insert a flat head screwdriver into the power socket and gently pry out the fuse holder Remove the bad fuse and replace with a new one The fuse holder has a built in socket f...

Страница 10: ... removed if the prod uct is modified in any manner which Elation Professionals concludes after inspec tion affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professionals factory unless prior written authori zation was issued to purchaser by Elation Professionals if the product is damaged because not properly maintained as set forth...

Отзывы: