Страница 1: ...ACL 360 MATRIX user manual E L A TI ON ACL 360 MATRIX user manual...

Страница 2: ...PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss a...

Страница 3: ...O N T E N T S General Information 4 Warranty 6 Safety Instructions 7 General Guidelines 8 Fixture Overview 9 Fixture Installation 10 Fixture Menu 13 DMX Channel Functions And Values 18 Error Codes 28...

Страница 4: ...e and maintenance UNPACKING Every fixture has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during sh...

Страница 5: ...purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the...

Страница 6: ...aser by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this...

Страница 7: ...Installation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fix...

Страница 8: ...jacent surfaces Be sure no air ventilation slots are blocked DO NOT attempt installation and or operation without knowledge how to do so DO NOT permit operation by persons who are not qualified to ope...

Страница 9: ...X User Manual Ver 1 F I X T U R E O V E R V I E W 1 LCD Control Display 6 Fuse 2 DC Switch 7 powerCON IN 3 UP DOWN LEFT RIGHT ENTER Buttons 8 3pin 5pin DMX IN 4 MODE Button 9 3pin 5pin DMX OUT 5 NET I...

Страница 10: ...or added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture...

Страница 11: ...iodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture...

Страница 12: ...riately rated clamp to the included Omega Brackets using a M10 screw fitted through the center hole of the Omega Bracket Be sure to attach an appropriate Safety Cable not included to the fixture using...

Страница 13: ...ions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN buttons to ad...

Страница 14: ...Number Fan Set Auto High Low Set Head Fan Speed ProtocolSet ArtNet Kling Net Fans Speed Select Net Switch ON OFF Activate NET OUT Port LCD Set Backlight 02 60m 05m LCD Backlight Shut Off Time FlipDis...

Страница 15: ...y Outside Stores Scenes via Ext DMX Console Sce Input XX XX Automatic Scenes Recorder Function Status Remote Add When ON define the desired DMX address of fixture via an external controller 1 Connect...

Страница 16: ...gs like adjusting the DMX starting address are no longer needed This is especially useful when the device is installed in a remote area RDM ready and conventional DMX devices can be operated in one DM...

Страница 17: ...r has been knocked slightly out of place Because improper use of this function can result in undesired operation this function has been password protected The password is 050 and must be entered each...

Страница 18: ...ovement 4 4 TILT MOVEMENT 16 BIT 0 255 Fine Control of TILT Movement 3 5 5 PAN CONTINUOUS MOVEMENT 0 127 NO FUNCTION 128 189 PAN Clockwise from FAST to SLOW 190 193 NO Rotation 194 255 PAN Counter Clo...

Страница 19: ...5 0 to 100 16 GREEN LED 3 0 255 0 to 100 17 BLUE LED 3 0 255 0 to 100 18 WHITE LED 3 0 255 0 to 100 19 RED LED 4 0 255 0 to 100 20 GREEN LED 4 0 255 0 to 100 21 BLUE LED 4 0 255 0 to 100 22 WHITE LED...

Страница 20: ...100 36 GREEN LED 8 0 255 0 to 100 37 BLUE LED 8 0 255 0 to 100 38 WHITE LED 8 0 255 0 to 100 39 RED LED 9 0 255 0 to 100 40 GREEN LED 9 0 255 0 to 100 41 BLUE LED 9 0 255 0 to 100 42 WHITE LED 9 0 25...

Страница 21: ...0 56 GREEN LED 13 0 255 0 to 100 57 BLUE LED 13 0 255 0 to 100 58 WHITE LED 13 0 255 0 to 100 59 RED LED 14 0 255 0 to 100 60 GREEN LED 14 0 255 0 to 100 61 BLUE LED 14 0 255 0 to 100 62 WHITE LED 14...

Страница 22: ...0 76 GREEN LED 18 0 255 0 to 100 77 BLUE LED 18 0 255 0 to 100 78 WHITE LED 18 0 255 0 to 100 79 RED LED 19 0 255 0 to 100 80 GREEN LED 19 0 255 0 to 100 81 BLUE LED 19 0 255 0 to 100 82 WHITE LED 19...

Страница 23: ...the specific Pan Tilt position of the head MODE CHANNEL VALUE FUNCTION BASIC STAND EXTEND 95 RED LED 23 0 255 0 to 100 96 GREEN LED 23 0 255 0 to 100 97 BLUE LED 23 0 255 0 to 100 98 WHITE LED 23 0 2...

Страница 24: ...CRO 03 13 16 COLOR MACRO 04 17 20 COLOR MACRO 05 21 24 COLOR MACRO 06 25 28 COLOR MACRO 07 29 32 COLOR MACRO 08 33 36 COLOR MACRO 09 37 40 COLOR MACRO 10 41 44 COLOR MACRO 11 45 48 COLOR MACRO 12 49 5...

Страница 25: ...40 161 164 COLOR MACRO 41 165 168 COLOR MACRO 42 169 172 COLOR MACRO 43 173 176 COLOR MACRO 44 177 180 COLOR MACRO 45 181 184 COLOR MACRO 46 185 188 COLOR MACRO 47 189 192 COLOR MACRO 48 193 196 COLO...

Страница 26: ...CRO 03 31 40 PROGRAM MACRO 04 41 50 PROGRAM MACRO 05 51 60 PROGRAM MACRO 06 61 70 PROGRAM MACRO 07 71 80 PROGRAM MACRO 08 81 90 PROGRAM MACRO 09 91 100 PROGRAM MACRO 10 101 110 PROGRAM MACRO 11 111 12...

Страница 27: ...18 114 PAN TILT MOVEMENT SPEED 0 225 MAX to MIN SPEED 226 235 Blackout By Movement 236 255 NO FUNCTION 17 19 115 LAMP ON OFF RESET INTERNAL PROGRAMS 0 79 Normal 80 84 ALL Motor Reset 85 99 NO FUNCTION...

Страница 28: ...not located in the default position after the reset This message will appear after a fixture reset if the magnetic indexing circuit malfunctions sensor failed or magnet is missing or there is a motor...

Страница 29: ...refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following poin...

Страница 30: ...Button Touch Control Panel Full Color 180 Reversible LCD Menu Display 8 16 Bit Resolution Adjustable Movement 3pin 5pin DMX In Out RJ45 Ethernet In Out KlingNET Art NET powerCON Power In Out SIZE WEIG...

Страница 31: ...ux fc lux fc RED LEDs 15 116 1 404 9 537 886 7 623 708 5 847 543 4 518 420 GREEN LEDs 33 054 3 071 25 468 2 366 18 072 1 679 12 970 1 205 9 849 915 BLUE LEDs 5 263 489 4 632 430 3 873 360 3 095 288 2...

Страница 32: ...l i g h t i n g c o m 32 ACL 360 MATRIX User Manual Ver 1 DIMENSIONAL DRAWINGS Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any...

Страница 33: ...ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp EWDMXSYSTEM Wireless DMX System 1 Transmitter 1 Receiver CAT005 5 1 5m CAT6 EtherCON Cable PLC3 3 ft 1m PowerCON PRO Link Cable A...