w w w . e l a t i o n l i g h t i n g . c o m
25
FUZE WASH Z120™ User Manual
E R R O R C O D E S
When power is applied, the unit will automatically enter a
“Motor Reset”
mode, which
brings all the internal motors to a home position. If there is an internal problem with
one or more of the motors, an error code (see below) will flash on the control display.
ERROR CODE
DESCRIPTION
TILT Er
The TILT movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a motor
failure (defective motor or defective motor IC drive on main PCB). This
error may also be displayed if the head was blocked during a reset
function
PAN Er
The PAN movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a motor
failure (defective motor or a defective motor IC drive on the main PCB).
This error may also be displayed if the head/yoke was blocked during a
reset function.
ZOOM Er
The ZOOM movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a motor
failure (defective motor or a defective motor IC drive on the main PCB).
This error may also be displayed if the head/yoke was blocked during a
reset function.