background image

 
 
 
 
 
 
 
 
 
 

 

 

INSTRUCTION MANUAL

 

SPECIFICATIONS 

  Stroke: 250 ÷ 8000 mm 

  Resistance 5 KOhm ±10% 

  Linearity ±0,25% 

(±0,3% for analogue output types)

 

  Speed: 0.5/1 m/sec. (see the table) 

  Spring max torque: strokes 

≤ 1250 mm = 600 g  

    Strokes from 1.5 to 4 m = 1000 g - Over: 2200 g 

  SUS304 stainless steel wire covered with nylon  

 0,6/1 mm 

– 

max load 16/60 Kg. (see the table) 

  Operating temperature -20 ÷ 70°C 

 (0 ÷ 70°C for analogue output 

types) - 

 Relative moisture  35%-90%

 

  Connections: cable 1 m long  (

HPS-S 

0.5 m)  

  Protection degree IP64   (

HPS-S

: IP50) 

 

 

Type 

Stroke 

mm

 

Power 

Speed 

Wire Ø  

/Max load 

Type 

Stroke 

mm

 

Power 

Speed 

Wire Ø  

/Max load 

HPS-M-05   

500 

1W 

1 m/sec 

0.7 mm/ 23 Kg. 

HPS-S-025  

250 

1W 

0.5 m/sec 

0.6 mm/ 16 Kg. 

HPS-M-075  

750 

1W 

1 m/sec 

0.7 mm/ 23 Kg. 

HPS-S-05  

500 

1W 

0.5 m/sec 

0.6 mm/ 16 Kg. 

HPS-M-10 

1000 

2W 

1 m/sec 

0.7 mm/ 23 Kg. 

HPS-S-10  

1000 

2W 

0.5 m/sec 

0.6 mm/ 16 Kg. 

HPS-M-125  

1250 

2W 

1 m/sec 

0.7 mm/ 23 Kg. 

HPS-L-30  

3000 

2W 

0.6 m/sec 

1 mm/ 60 Kg. 

HPS-M-15   

1500 

2W 

1 m/sec 

0.7 mm/ 23 Kg. 

HPS-L-40  

4000 

2W 

0.6 m/sec 

1 mm/ 60 Kg. 

HPS-M-20    

2000 

2W 

1 m/sec 

0.7 mm/ 23 Kg. 

HPS-L-50  

5000 

2W 

0.6 m/sec 

1 mm/ 60 Kg. 

HPS-M-30  

3000 

2W 

1 m/sec 

0.7 mm/ 23 Kg. 

HPS-L-60  

6000 

2W 

0.6 m/sec 

1 mm/ 60 Kg. 

HPS-M-40  

4000 

2W 

1 m/sec 

0.7 mm/ 23 Kg. 

HPS-L-80  

8000 

2W 

0.6 m/sec 

1 mm/ 60 Kg. 

 

INSTALLATION 

 Make  sure  that  the  distance  to  be  run  by  the  wire  does  not  exceed  the  transducer  nominal  stroke;  stretching  the  wire  over  its 

nominal stroke damages the transducer seriously, and causes the decay of the garantee right. 

 Use 4 M3 screws with the following specifications to fix the potentiometer: 

HPS-M

 screws M3x8 - 

HLS-S

 screws M3x6             

   

– 

HLS-L

 screws M4x10 

 The wire must run out of the bushing without angle to obtain the best tolerance in measurements. 

 It is possible to hook the fixing end of the wire at a steady point and move the transducer body instead of the wire. 

 If the application is not a linear one, use a pulley with a proper diameter to smooth the rotation and avoid damaging the wire. 

 If the product works in a severe environment, such as in presence of oil, water, heavy dust, iron chipping or any powder which can 

damage  the wire, apply a protective cover. 

 

CONNECTIONS 

Carry out the connections as shown in the diagram hereunder. The cable shield is not connected inside the transducer. 

 HPS-M, HPS-S, HPS-L

 

 HPS-M 10V, HPS-L 10V

 

 HPS-M 420, HPS-L 420

 

The red and black 
wires are connected 
to the resistance 
ends, while the 
white wire is 
connected to the 
cursor 

 

 

 
 
 
 
 
 

 

 

LINEAR WIRE  

POTENTIOMETER 
HPS-M  

  HPS-S  

 

 HPS-L 

 

 

 
 
 

 

 

HPS 

 

 

 

 