background image

100EM

Tabletop/Under-Cabinet

10" Color Touch Panel

INSTALLATION MANUAL

Содержание VIA! VALET100EM

Страница 1: ...100EM Tabletop Under Cabinet 10 Color Touch Panel INSTALLATION MANUAL...

Страница 2: ......

Страница 3: ...that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off an...

Страница 4: ......

Страница 5: ...heater 7 Stand Alone Home Theater Expanded 8 ELAN System12 9 ELAN System8 10 ELAN System6 11 RS 232 Controlled Devices Regardless of System Type 12 Installation 13 Pre Wire 13 Control Status Power 13...

Страница 6: ...S Page 2 ELAN Home Systems 2008 All rights reserved Sense Port 27 Operation 28 Timeout 28 Video Mode 28 Video Overlays 28 Cleaning 28 Cleaning Mode 29 Troubleshooting 30 Specifications 31 Programming...

Страница 7: ...plastic film suspended over a glass panel which is then adhered to the front of a color LCD Liquid Crystal Display screen Depressing the polyester film with a finger allows the film to touch the glas...

Страница 8: ...1 2 The display rotates up to 330 from its stow position allowing you to view the display from almost anywhere in the room as shown in Figure1 2 When the VIA Valet100EM is not being used simply rotate...

Страница 9: ...m eowner make a detailed list of all components Include source equipment keypads touch panels volume controls amplifiers com munications gear etc Gather up any IR remote controls that may be necessary...

Страница 10: ...s or electromagnetic interference such as CRT monitors light dim mers and some power supplies Do not mount the VIA Valet100EM outdoors or in areas exceeding its operating temperature range of 10 F 23...

Страница 11: ...a Home Theater controller The diagram below shows a basic application using one VIA Valet100EM a PVIA1 Valet Wall Plate and an ELAN IRD4 Amplified IR Connection Block to control a stack of A V equipm...

Страница 12: ...The diagram below shows a VIA Valet100EM A PVIA1 Valet Wall Plate two VIA 70EMs and a PVIA4 Wall Plate controlling a stack of A V gear PVIA4 PVIA 4 VIDEO IN 1 2 3 4 16VDC POWER 9 VDC SENSE INPUTS IR...

Страница 13: ...12 The diagram below shows one VIA Valet100EM Touch Panel one PVIA1 Valet Wall Plate four VIA 70EM Touch Panels and a SPP connected to an ELAN S12 S12 PVIA1 Valet SPP IR OUT VIDEO OUT 9VDC PWR9 16VDC...

Страница 14: ...a VIA Valet100EM with an S8 The diagram below shows one VIA Valet100EM Touch Panel one PVIA1 Valet Wall Plate four VIA 70EM Touch Panels and an SPP Precision Panel con nected to an ELAN S8 PVIA1 Vale...

Страница 15: ...iagram below shows a VIA Valet100EM a PVIA1 Valet Wall Plate four VIA 70EMs and a SPP Precision Panel configured for use with an ELAN S6 PVIA1 Valet S6 PWR4 PWR1 IR OUT VIDEO OUT 9VDC PWR9 16VDC PWR1...

Страница 16: ...uch Panels in the system PVIA10 VIA SC4 PVIA4 PVIA 4 VIDEO IN 1 2 3 4 16VDC POWER 9 VDC SENSE INPUTS IR OUT 1 2 3 4 ALL SYS SENSE TO VIA NET 1 2 3 4 SPP RS 232 Devices Stand Alone Systems S12 S8 S6 Sy...

Страница 17: ...ll Plate are to be installed The VIA Valet100EM will be powered locally using the included PWR1 Power Supply connected directly to the PVIA1 Valet Wall Plate Video The VIA Valet100EM has both a Video...

Страница 18: ...er to the F connector of the coax run The VIA Valet100EM has F connectors on both the VIDEO IN Input and VIDEO OUT Output Video Termination Switch When the video signal coming into a VIA Touch panel i...

Страница 19: ...ll cable strain relief clamp Connect the other end to the TO VIA VALET jack on the PVIA1 Valet Wall Plate 3 Optional Local Port Connection The LOCAL port is not normally used with the VIA Valet100EM I...

Страница 20: ...cabinet 1 Choose an appropriate mounting location underneath the desired cabinet or shelf 2 Using the provided VIA Valet100EM Adhesive Backed Mounting Template carefully place the template in position...

Страница 21: ...et 5 Measure the thickness of the bottom of the cabinet or shelf Select the shortest screw length which will pass completely through the cup washer and cabinet shelf Screw length must protrude from un...

Страница 22: ...ASHER 4 VIAValet100EM Bottom Figure 3 7 Base Mounting 7 Make the appropriate cable connections and secure the VIA VALET100 to the cabinet by tightening the four screws DO NOT OVER TIGHTEN Figure 3 8 U...

Страница 23: ...LAN s IRD4 Amplified Connection Block Signals originate at the VIA Valet100EM pass through the PVIA1 Valet Wall Plate then travel to the connection block where they are routed to each component NOTE T...

Страница 24: ...n Manual for additional details SPP VIA Connector IR 485 485 GND 16V GND 16V SN To Front of PVIA1 Valet 16V GND 16V GND V485 V485 IR ST SNS Z485 Z485 SIR PVIA1 Valet Rear Figure 3 10 S12 Connections 1...

Страница 25: ...PVIA1 Valet Wall Plate to the VIA Valet100EM as shown Connect IR RS485 and GND between the PVIA1 Valet Wall Plate and the SPP as shown Multiple VIA s will connect in the same way Please consult the S...

Страница 26: ...lease consult the SPP Installation Manual for use of an SPP Precision Panel with a S6 BLUE WHITE BLUE ORANGE WHITE ORANGE GREEN WHITE GREEN BROWN WHITE BROWN 1 2 3 4 5 6 7 8 PIN COLOR CODE FRONT CABLE...

Страница 27: ...he External Power Connector In applications where it is not desirable to use a local PVIA1 Valet Wall Plate is is recommended to use 18AWG 2 conductor wire between the PWR1 and the VIA Valet100EM Touc...

Страница 28: ...rights reserved Local Interface Port Use this connector when utilizing local control features such as local source control local IR receivers or sense enabled automated sequences Local Interface Port...

Страница 29: ...stribution block connected to the IR OUT LOC in two ways 1 Any IR signal that is received from the Local IR Input is sent out of the Local IR Output RJ 45 Port the SYS IR Output RJ 45 Port and the IR...

Страница 30: ...d near a TV or an auxil lary IR receiver placed in an area more convenient than the location of the touch panel Any IR signal that is received from the Local IR Input is sent out the Local IR Output R...

Страница 31: ...programmed in VIA TOOLS For example use a motion sensor to activate a contact closure and cause automated actions such as system power on drapes closed and lights dimmed Connect SENSE and GROUND to a...

Страница 32: ...on EXIT FROM VIDEO MODE is also pres ent These buttons are Autobuilt in VIA TOOLS and will allow the homeowner to display a specific camera or all cameras as desired See VIA TOOLS Help file for more s...

Страница 33: ...d on the VIA Valet100EM with a 30 second delay programmed under it This allows the hom eowner to clean the screen without initiating any commands to the system The CLEAN button should be placed in a l...

Страница 34: ...ect IR con nections 2 Incorrect or missing IR RS232 commands in VIA TOOLS 1 Verify IR connections and test with IR Emitter with talk back LED 2 Verify commands in VIA TOOLS Unit will activate but disp...

Страница 35: ...r Video Loop OUT F connector Power Terminal 2 Pin Local Interface 5 Pin Wiring Requirements Cat 5 Data RG 6 or RG 59 coaxial cable Composite Video Display Graphics Resolution Signal Viewing Angles Hig...

Страница 36: ...etween the PC and the touch panel to be programmed It is NOT NECESSARY to power the VIA VALET100EM during programming making it pos sible to program and download to multiple units prior to installatio...

Страница 37: ...in an under cabinet application the panel trim bezel Logo may be removed and remounted in a 180 degree configuration 1 Remove 2 screws from rear panel location as shown in Figure C 1 2 Remove Logo ba...

Страница 38: ...VIA VALET100EM E LA N H OM E S Y S T E M S Page 34 ELAN Home Systems 2008 All rights reserved Notes...

Страница 39: ......

Страница 40: ...y ELAN the warranty obligations of ELAN shall in all respects conform to the warranty actually extended to ELAN by its supplier The foregoing warranties do not cover reimbursement for labor transporta...

Страница 41: ...0EM LINEAR P N 9905959 REV B 2008 INK BLACK MATERIAL 60 LB WHITE COATED PAPER SCALE 1 1 FLAT SIZE 11 000X8 500 FLAT TOL 40 FOLD ONCE TO 5 500X8 500 SADDLESTITCH ARTWORK CREATED BY ELAN HOME SYSTEMS NU...

Отзывы: