E L A N H O M E S Y S T E M S
INSTALLATION MANUAL
© ELAN Home Systems 2009 • All rights reserved. Page 31
S128P
“B” Punchdown Locations-12V
The SPP Precision panel has the ability to connect touchpanels, keypads and Olé Touchpads in various
combinations in each zone. The “B” punchdown location can either pass 12VDC power from the S128P Controller
(Internal Power) or 16VDC from a power supply connected to the front of the SPP (External).
Figure 3-7
shows
connectivity to the “B” location and utilizing internal 12VDC power from the S128P Multi-Room Controller.
NOTE: Place the “INT 12V/EXT 16V” switch in the UP (“INT 12V”)
position for this application.
IMPORTANT NOTE
Olé Touchpads
Use the correct power
supply connected to the front
of the SPP for the number
or Olé Touchpads and VIA!
Touch Panels in the system.
Olé Touchpad to SPP Precision Panel (Using 12VDC from S128P)
Figure 3-7: Olé Touchpad “B” Internal 12VDC Connections
ELAN Precision Panels save
time and make sense out
of complex wiring jobs!
+
-
-
VIA!NET
16VDC / 10A
16VDC / 4A
16VDC/1.5A
1
ZONE
2
ZONE
3
ZONE
4
ZONE
SS/SC4
5
ZONE
6
ZONE
7
ZONE
8
ZONE
TO SENSE INPUTS
EXT IR
1
2
3
USE STEREO 3.5mm PLUGS ONLY
4
5
6
1
TRIGGERS
2
3
4
5
6
7
8
POWER
S128P.indd 31