Elan DSC MAXSYS Series Скачать руководство пользователя страница 2

2 of 6 

I

NSTALLATION 

O

VERVIEW

 

1.  Mount the PC4401 inside the MAXSYS panel, and connect the PC4401 to the controller 

according to the DSC documentation. 

2.  Install and setup the security system. 

3.  Run a Cat5 wire from the 

g!

 system to the security panel and test the cable. 

4.  Test the security panel, zone sensors and keypads for functionality. 

5. Connect 

the 

g!

 system to the panel electrically.  

6. Configure 

the 

g!

 system controller communication device and security panel and confirm 

communication between the panel and the 

g!

 system controller. 

7.  Fault all the zones in the system.  Faulting the zone sends a message to the 

g!

 system which 

then automatically adds the zone in the Configurator.  Zones that can’t be easily faulted must be 
added by hand.  Confirm that all zones are visible in the Configurator, and then provide names 
for each zone and partition with the Configurator. 

8.  Test the arming and disarming capability from a computer or touch screen and confirm history 

function. 