Features

‘Class T’ Design

‘Class T’ allows the D1650 to deliver its full rated

power from all sixteen channels simultaneously and

is 90% efficient so that the amplifier does not waste

energy producing excessive heat.

Dual Stereo Bus

BUS A and BUS B inputs and outputs allow the

amplifier to be configured in dozens of different

ways to meet the demands of large audio distribu-

tion systems.  Channels can be assigned to one of

two audio busses in order to be split or combined

according to situational demands.

Audio inputs can be BUS A, BUS B, Independent,

Stereo, or Mono without the use of extraneous

patch cables. Additional amplifiers can be connect-

ed from the Line outputs of the D1650 to provide

greater system expansion.

ACE™ (Automatic Clip Eliminator)

Microprocessor-controlled dynamic leveling circuit

eliminates clipping without audio degradation typical

with traditional compressor-based clipping circuits.

Each amplified output is continuously monitored for

signal clipping.  Extremely fast transients are

ignored but if ACE sees a consistent clipping trend,

it turns the respective channel down by one incre-

ment.  This action is repeated until no more clipping

is detected.  Once clipping is absent for five sec-

onds, ACE will slowly and unnoticeably begin to

restore the original gain settings. This translates into

accurate, high quality audio reproduction at all vol-

ume levels.

Individual Remote Trigger Inputs/

Trigger Output

Eight +12VDC Trigger Inputs allow each pair of

channels to be powered up and muted independent-

ly.  The +12VDC Trigger Output turns on and mutes

additional amplifiers.

Signal Presence and Clipping

Indicators

High-visibility blue LED display and front panel

Channel Select and Volume Adjustment controls

make setup easy. Blue Signal LEDS show when

audio is present on each input.  Red Clipping LEDS

indicate distortion, and make fine tuning the amplifi-

er very straightforward.  Five blue LEDs fire down-

ward to softly indicate Power status.  The Signal

Level and Power LEDs feature adjustable bright-

ness.

Digital Volume Level Set/Lockout

All channel volume levels are matched to within

0.3dB, making volume setup easy, accurate, and

repeatable.  Volume settings are stored within the

D1650's non-volatile memory upon exiting setup.

This means that settings are preserved even when 

a power outage occurs. 

A special multi-button key press can be used to

lock the volume settings so that they can not be

tampered with. The user may view their settings

when the system is locked, but is unable to change

them.

Advanced Amplifier Protection

Each channel of the D1650 is coupled to its respec-

tive WECO speaker terminal via a high power relay.

If the processing circuitry senses a fault condition

(over heating, shorted output, etc.), it will completely

disconnect the amplifier channel from the output

load.  Faulted conditions will be indicated on the

front panel.  After finding and correcting the problem

causing the fault condition, simply power the unit

OFF and back ON to restore operation.

Rack Mount Aluminum Front

Panel w/ Rugged Handles (D1651)

Amplifier mounts securely to equipment racks.

Handles are invaluable when moving, installing,

adjusting or servicing the unit.

Содержание D1650

Страница 1: ...16 CHANNEL DIGITAL POWER AMPLIFIER I N S T A L L A T I O N M A N U A L A N D U S E R S G U I D E D1650 D1651 SIXTEEN CHANNELS OF DIGITAL COOL...

Страница 2: ...ce These sys tems allow people to move room to room control ling centrally located equipment with ease ELAN s product line includes Power Amplifiers Zoned Pre Amps Intelligent Keypads LCD Color Touch...

Страница 3: ...tions should be heeded Wall Mounting Mounting of this appliance should be done only by an authorized installer Ventilation The appliances should be situated so that their location or position does not...

Страница 4: ...may touch dangerous voltage points or short out parts that could result in a fire or electric shock Care should be taken so that objects do not fall and liquids are not spilled into the appliance thr...

Страница 5: ...ty Information 3 System Overview 6 Specifications 6 Features 7 Class T Explained 8 2 Connections and Applications Independent Stereo Zones 9 Two Room Stereo Zones 10 Stereo Zones with Mono Sub Zones 1...

Страница 6: ...ors Power AC Power Requirements 120 VAC 1200 Watts Power Supply Ultra high efficiency toroidal transformer Triggers Remote Trigger Inputs 5 to 24 Volts AC DC Trigger Loop Output 12VDC 0 1A Dimensions...

Страница 7: ...t 12VDC Trigger Inputs allow each pair of channels to be powered up and muted independent ly The 12VDC Trigger Output turns on and mutes additional amplifiers Signal Presence and Clipping Indicators H...

Страница 8: ...mid conduction This mid conduction state is what causes linear switch ing amplifiers to be as inefficient as they are less than 50 efficiency Class D amplifiers are approx imately 85 efficient a 35 in...

Страница 9: ...s on a zone by zone or system wide basis Independent Stereo Zones The D1650 is set up to easily power eight independ ent stereo zones right out of the box This is the standard configuration for most m...

Страница 10: ...OUTPUTS Two Room Stereo Zone By using the D1650 s Audio Loop an additional pair of speakers can be added to a zone In this example both pairs of speakers will ramp volume up and down simultaneously T...

Страница 11: ...utput to Line Inputs 1 2 Line Outputs 1 2 to RCA Y Cable RCA Y Cable to Line Input 3 All Speakers Volume Ramps Up Down Together Speaker Outputs Coincide w Line Inputs Stereo Zones w Mono Sub Zones Use...

Страница 12: ...area such as hallways L shaped rooms kitchens and outdoor areas The use of mono zones also increases the capacity of the amplifier up to sixteen mono areas can be powered from one D1650 In this examp...

Страница 13: ...Room Controller ZONE OUTPUTS Bus Modes The D1650 s unique Bus Mode feature allows multi ple amp Inputs to be internally configured to several different Outputs This increases the amp s flexibili ty wi...

Страница 14: ...urce can be used As in the ALL ON example any 3 24 Volt AC or DC source may be used to trigger these specific inputs This application gives additional control in advanced systems Examples include Zone...

Страница 15: ...r all channels Please Note Whenever the Front Display is lit dur ing volume adjustment for example ACE clipping elimination circuitry is disabled Lockout Mode The Lockout feature is designed to disabl...

Страница 16: ...1 Turn the D1650 OFF using the rear Power Switch 2 Turn the unit back ON The Front Display will read ELAN 3 Press and hold C C V and V all the front panel buttons at once while ELAN is dis played 4 Th...

Страница 17: ...pedance condition Correct overheating or AC power issues Once issue is found and resolved cycle power to D1650 This condition could be caused by 1 2 3 and or 4 above Audio Hum 1 Ground Potential Diffe...