background image

• 

RISK OF ELECTRIC SHOCK – Use only in dry locations and only 
indoors. 

• 

DO NOT plug into another relocatable power tap. 

• 

DO NOT “daisy chain” surge protectors.  

• 

DO NOT plug into 220V outlet or power source. 

• 

DO NOT use with any aquarium equipment. 

• 

DO NOT connect to an ungrounded outlet. 

• 

DO NOT install this device if there is not at least 30 feet (10 meters), 
or more of wire between the electrical outlet and electrical service 
panel. 

• 

This device features internal protection that will disconnect the 
surge protective component at the end of its useful life 
(PROTECTED LED WILL TURN OFF) , but will maintain power to the 
outlets – WHICH WILL BE UNPROTECTED.  If you don’t want your 
equipment at risk, the surge protector will need to be replaced.  

• 

DO NOT use in any circumstance that would affect the operation or 
reliability of life support equipment, any medical applications, or 
patient care. 

SAFETY INFORMATION 

TECHNICAL SPECIFICATIONS 

Number of Outlets 

6 (4 Group Controlled / 2 Always on) 

Wi-Fi 2.4Ghz 

Only 

AC Outlets 

All 6 filtered with surge protection 

Protection Modes 

L-N, L-G, N-G 

Thermal Fuse 

Yes 

Maximum Current 

15 Amps 

Line Voltage 

120V @ 60Hz 

Certification 

UL 1449 + UL1363 / FCC Part 15B + ICES 

Max Energy Dissipation 

540 Joules 

Max Spike Voltage / Current 

6,000V / 36,000A 

Response Time 

1 Nanosecond 

Filtration 

EMI / RFI 40dB 

Home Automation Compatibility 

Google Assistant / Alexa 

App Controllable 

Yes (Download ELAC Protek App) 

CAUTIONS! 

This surge protector is designed to protect your electronic equipment from AC power surges up to its rated specifications only. If an electrical surge above the rated specifications of this 
surge protector enter this device, connected devices may not be protected. Please understand that electrical surges can enter electronics devices through any interconnected 
conductive connections. These interconnections can include coax lines, phone lines, ethernet lines, AV connections and any other conductive material.  

FCC and IEC Statement 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and  used in accordance 
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment 
does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference 
by one or more of the following measures: 

• 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the equipment and receiver. 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

• 

Consult the dealer or an experienced radio/TV technician for help. 

To assure continued FCC compliance: 

1. Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. 

2. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm 
between the radiator & your body. 

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this 
device must accept any interference, including interference that may cause undesired operation of the device. 

This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm 
between the radiator and your body. 

WARRANTY 

ELAC Americas Inc. warrants to the original purchaser that this product be free from defects and or workmanship for 3-Years from the original date of purchase. During this time period, 
repair or replacement will be free of charge to the original owner (See below limitations). Shipping to and return from the repair center will be the responsibility of the original purchaser.  

 
Limitations 
 

• 

Warranty begins on the date of original purchase from an authorized ELAC Americas Inc. dealer. Products purchased from an unauthorized reseller will not be honored.  

• 

Product is warranted only if used in home applications within the rated specifications of this product.  Commercial use of this product is not warranted. 

• 

Product that has been modified or altered in anyway will not be warranted. 

• 

Product that has been abused or subjected to faulty equipment will not be warranted. 

• 

Products with defaced or removed serial numbers will not be warranted. 

If service is required 
 
In the event that service is required, please contact ELAC America at 714-252-8843 or at [email protected] to request a return authorization and to arrange for service or 
replacement. Whether the product will be serviced or replaced is at ELAC’s discretion. You will be responsible to provide proof of purchase (Copy or original sales receipt). Shipping to 
and from our repair center will be the responsibility of the original purchaser.  

ELAC AMERICAS INC. 

1938 N. BATAVIA ST. SUITE K 

ORANGE, CA 92865 

Copyright 2021 ELAC Americas Inc. 

Отзывы: